{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,6]],"date-time":"2026-09-06T04:40:04Z","timestamp":1788669604038,"version":"build-2803163510"},"reference-count":30,"publisher":"Springer Science and Business Media LLC","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2024,1,16]]},"DOI":"10.7759\/cureus.52369","type":"journal-article","created":{"date-parts":[[2024,1,16]],"date-time":"2024-01-16T14:20:46Z","timestamp":1705414846000},"source":"Crossref","is-referenced-by-count":6,"title":["Tandem T:Slim X2 Insulin Pump Use in Clinical Practice Among Pregnant Individuals With Type 1 Diabetes: A Retrospective Observational Cohort Study"],"prefix":"10.7759","author":[{"given":"Neeharika","family":"Nandam","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stephen","family":"Thung","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kartik K","family":"Venkatesh","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Steven","family":"Gabbe","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jianing","family":"Ma","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jing","family":"Peng","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kathleen","family":"Dungan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elizabeth  O","family":"Buschur","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.2337\/diaspect.29.2.92","article-title":"Insulin use in pregnancy: an update","volume":"29","author":"Blum AK","year":"2016","unstructured":"Blum AK. Insulin use in pregnancy: an update. Diabetes Spectr. 2016, 29:92-7. 10.2337\/diaspect.29.2.92","journal-title":"Diabetes Spectr"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.3109\/14767058.2013.864631","article-title":"Insulin therapy for the treatment of type 1 diabetes during pregnancy","volume":"27","author":"Lenhard MJ","year":"2014","unstructured":"Lenhard MJ, Kinsley BT. Insulin therapy for the treatment of type 1 diabetes during pregnancy. J Matern Fetal Neonatal Med. 2014, 27:1270-5. 10.3109\/14767058.2013.864631","journal-title":"J Matern Fetal Neonatal Med"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.2337\/dc18-0771","article-title":"Predictive low-glucose suspend reduces hypoglycemia in adults, adolescents, and children with type 1 diabetes in an at-home randomized crossover study: results of the Prolog trial","volume":"41","author":"Forlenza GP","year":"2018","unstructured":"Forlenza GP, Li Z, Buckingham BA, et al.. Predictive low-glucose suspend reduces hypoglycemia in adults, adolescents, and children with type 1 diabetes in an at-home randomized crossover study: results of the Prolog trial. Diabetes Care. 2018, 41:2155-61. 10.2337\/dc18-0771","journal-title":"Diabetes Care"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1080\/17434440.2020.1784724","article-title":"Closed-loop control in insulin pumps for type-1 diabetes mellitus: safety and efficacy","volume":"17","author":"Fuchs J","year":"2020","unstructured":"Fuchs J, Hovorka R. Closed-loop control in insulin pumps for type-1 diabetes mellitus: safety and efficacy. Expert Rev Med Devices. 2020, 17:707-20. 10.1080\/17434440.2020.1784724","journal-title":"Expert Rev Med Devices"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1089\/dia.2022.0540","article-title":"Expert guidance on off-label use of hybrid closed-loop therapy in pregnancies complicated by diabetes","volume":"25","author":"Szmuilowicz ED","year":"2023","unstructured":"Szmuilowicz ED, Levy CJ, Buschur EO, Polsky S. Expert guidance on off-label use of hybrid closed-loop therapy in pregnancies complicated by diabetes. Diabetes Technol Ther. 2023, 25:363-73. 10.1089\/dia.2022.0540","journal-title":"Diabetes Technol Ther"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.5603\/GP.a2021.0029","article-title":"Continuous glucose monitoring and insulin pump therapy in pregnant women with type 1 diabetes mellitus","volume":"92","author":"Lason I","year":"2021","unstructured":"Lason I, Cyganek K, Witek P, Matejko B, Malecki MT, Skupien J. Continuous glucose monitoring and insulin pump therapy in pregnant women with type 1 diabetes mellitus. Ginekol Pol. 2021, 92:675-81. 10.5603\/GP.a2021.0029","journal-title":"Ginekol Pol"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa1602494","article-title":"Closed-loop insulin delivery during pregnancy in women with type 1 diabetes","volume":"375","author":"Stewart ZA","year":"2016","unstructured":"Stewart ZA, Wilinska ME, Hartnell S, et al.. Closed-loop insulin delivery during pregnancy in women with type 1 diabetes. N Engl J Med. 2016, 375:644-54. 10.1056\/NEJMoa1602494","journal-title":"N Engl J Med"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.2337\/dc20-2762","article-title":"User engagement with the Camaps FX hybrid closed-loop app according to age and user characteristics","volume":"44","author":"Chen NS","year":"2021","unstructured":"Chen NS, Boughton CK, Hartnell S, et al.. User engagement with the Camaps FX hybrid closed-loop app according to age and user characteristics. Diabetes Care. 2021, 44:e148-50. 10.2337\/dc20-2762","journal-title":"Diabetes Care"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.1002\/dmrr.3248","article-title":"Case series of a hybrid closed-loop system used in pregnancies in clinical practice","volume":"36","author":"Polsky S","year":"2020","unstructured":"Polsky S, Akturk HK. Case series of a hybrid closed-loop system used in pregnancies in clinical practice. Diabetes Metab Res Rev. 2020, 36:e3248. 10.1002\/dmrr.3248","journal-title":"Diabetes Metab Res Rev"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.1016\/j.aace.2020.11.039","article-title":"Commercialized hybrid closed-loop system (minimed medtronic 670G) results during pregnancy","volume":"7","author":"Moreno-Fern\u00e1ndez J","year":"2021","unstructured":"Moreno-Fern\u00e1ndez J, Garc\u00eda-Seco JA. Commercialized hybrid closed-loop system (minimed medtronic 670G) results during pregnancy. AACE Clin Case Rep. 2021, 7:177-9. 10.1016\/j.aace.2020.11.039","journal-title":"AACE Clin Case Rep"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.3390\/metabo12111137","article-title":"Carbohydrate intake and closed-loop insulin delivery system during two subsequent pregnancies in type 1 diabetes","volume":"12","author":"Munda A","year":"2022","unstructured":"Munda A, Kovacic C, Pongrac Barlovic D. Carbohydrate intake and closed-loop insulin delivery system during two subsequent pregnancies in type 1 diabetes. Metabolites. 2022, 12:1137. 10.3390\/metabo12111137","journal-title":"Metabolites"},{"key":"ref12","unstructured":"Tandem Diabetes Care Reports Preliminary, Unaudited 2022 Sales and Reaffirms 2023 Outlook. (2023). Accessed. January 25, 2023: https:\/\/www.businesswire.com\/news\/home\/20230110005917\/en\/."},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1080\/17425247.2020.1814734","article-title":"A clinical review of the t:slim X2 insulin pump","volume":"17","author":"Berget C","year":"2020","unstructured":"Berget C, Lange S, Messer L, Forlenza GP. A clinical review of the t:slim X2 insulin pump. Expert Opin Drug Deliv. 2020, 17:1675-87. 10.1080\/17425247.2020.1814734","journal-title":"Expert Opin Drug Deliv"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.2337\/dci19-0028","article-title":"Clinical targets for continuous glucose monitoring data interpretation: recommendations from the international consensus on time in range","volume":"42","author":"Battelino T","year":"2019","unstructured":"Battelino T, Danne T, Bergenstal RM, et al.. Clinical targets for continuous glucose monitoring data interpretation: recommendations from the international consensus on time in range. Diabetes Care. 2019, 42:1593-603. 10.2337\/dci19-0028","journal-title":"Diabetes Care"},{"key":"ref15","unstructured":"Dexcom\u2019s G7 Glucose Monitor Wins Awaited FDA Clearance. (2022). Accessed. January 25, 2023: https:\/\/www.medtechdive.com\/news\/dexcom-g7-fda-clearance\/638360\/#:~:text=The%20device%2C%20which%20Dexcom%20plans,as%...."},{"key":"ref16","unstructured":"U.S. FDA Clears Abbott's FreeStyle Libre\u00ae 2 and FreeStyle Libre\u00ae 3 Sensors for Integration with Automated Insulin Delivery Systems. (2023). https.\/\/www.prnewswire.com\/news-releases\/us-fda-clears-abbotts-freestyle-libre-2-and-freestyle-libre-3-sensors-for-in...."},{"key":"ref17","doi-asserted-by":"publisher","DOI":"10.1097\/AOG.0000000000002960","article-title":"ACOG practice bulletin No. 201: pregestational diabetes mellitus","volume":"132","year":"2018","unstructured":"ACOG practice bulletin No. 201. pregestational diabetes mellitus. Obstet Gynecol. 2018, 132:e228-48. 10.1097\/AOG.0000000000002960","journal-title":"Obstet Gynecol"},{"key":"ref18","doi-asserted-by":"publisher","DOI":"10.2337\/dc23-S015","article-title":"15. Management of diabetes in pregnancy: standards of care in diabetes-2023","volume":"46","author":"ElSayed NA","year":"2023","unstructured":"ElSayed NA, Aleppo G, Aroda VR, et al.. 15. Management of diabetes in pregnancy: standards of care in diabetes-2023. Diabetes Care. 2023, 46:S254-66. 10.2337\/dc23-S015","journal-title":"Diabetes Care"},{"key":"ref19","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajog.2020.08.063","article-title":"Society for maternal-fetal medicine special statement: updated checklist for antepartum care of pregestational diabetes mellitus","volume":"223","author":"Hameed AB","year":"2020","unstructured":"Hameed AB, Combs CA. Society for maternal-fetal medicine special statement: updated checklist for antepartum care of pregestational diabetes mellitus. Am J Obstet Gynecol. 2020, 223:B2-5. 10.1016\/j.ajog.2020.08.063","journal-title":"Am J Obstet Gynecol"},{"key":"ref20","doi-asserted-by":"publisher","DOI":"10.2337\/dc18-1581","article-title":"Glucose management indicator (GMI): a new term for estimating A1C from continuous glucose monitoring","volume":"41","author":"Bergenstal RM","year":"2018","unstructured":"Bergenstal RM, Beck RW, Close KL, et al.. Glucose management indicator (GMI): a new term for estimating A1C from continuous glucose monitoring. Diabetes Care. 2018, 41:2275-80. 10.2337\/dc18-1581","journal-title":"Diabetes Care"},{"key":"ref21","doi-asserted-by":"publisher","DOI":"10.2337\/dc08-0545","article-title":"Translating the A1C assay into estimated average glucose values","volume":"31","author":"Nathan DM","year":"2008","unstructured":"Nathan DM, Kuenen J, Borg R, Zheng H, Schoenfeld D, Heine RJ. Translating the A1C assay into estimated average glucose values. Diabetes Care. 2008, 31:1473-8. 10.2337\/dc08-0545","journal-title":"Diabetes Care"},{"key":"ref22","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbi.2008.08.010","article-title":"Research electronic data capture (REDCap)--a metadata-driven methodology and workflow process for providing translational research informatics support","volume":"42","author":"Harris PA","year":"2009","unstructured":"Harris PA, Taylor R, Thielke R, Payne J, Gonzalez N, Conde JG. Research electronic data capture (REDCap)--a metadata-driven methodology and workflow process for providing translational research informatics support. J Biomed Inform. 2009, 42:377-81. 10.1016\/j.jbi.2008.08.010","journal-title":"J Biomed Inform"},{"key":"ref23","unstructured":"The R Project for Statistical Computing. (2022). https.\/\/www.r-project.org\/."},{"key":"ref24","unstructured":"Microsoft 365 for Mac. (2022). https.\/\/www.microsoft.com\/en-us\/microsoft-365\/mac\/microsoft-365-for-mac."},{"key":"ref25","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajog.2012.06.029","article-title":"Insulin pump dosing across gestation in women with well-controlled type 1 diabetes mellitus","volume":"207","author":"Roeder HA","year":"2012","unstructured":"Roeder HA, Moore TR, Ramos GA. Insulin pump dosing across gestation in women with well-controlled type 1 diabetes mellitus. Am J Obstet Gynecol. 2012, 207:324.e1-5. 10.1016\/j.ajog.2012.06.029","journal-title":"Am J Obstet Gynecol"},{"key":"ref26","doi-asserted-by":"publisher","DOI":"10.2337\/diacare.27.12.2819","article-title":"Outcomes in type 1 diabetic pregnancies: a nationwide, population-based study","volume":"27","author":"Jensen DM","year":"2004","unstructured":"Jensen DM, Damm P, Moelsted-Pedersen L, Ovesen P, Westergaard JG, Moeller M, Beck-Nielsen H. Outcomes in type 1 diabetic pregnancies: a nationwide, population-based study. Diabetes Care. 2004, 27:2819-23. 10.2337\/diacare.27.12.2819","journal-title":"Diabetes Care"},{"key":"ref27","doi-asserted-by":"publisher","DOI":"10.1007\/s00125-011-2363-6","article-title":"Pathophysiology of postprandial hyperglycaemia in women with type 1 diabetes during pregnancy","volume":"55","author":"Murphy HR","year":"2012","unstructured":"Murphy HR, Elleri D, Allen JM, et al.. Pathophysiology of postprandial hyperglycaemia in women with type 1 diabetes during pregnancy. Diabetologia. 2012, 55:282-93. 10.1007\/s00125-011-2363-6","journal-title":"Diabetologia"},{"key":"ref28","doi-asserted-by":"publisher","DOI":"10.1089\/dia.2016.0349","article-title":"\u201cLet the algorithm do the work\u201d: Reduction of hypoglycemia using sensor-augmented pump therapy with predictive insulin suspension (SmartGuard) in pediatric type 1 diabetes patients","volume":"19","author":"Biester T","year":"2017","unstructured":"Biester T, Kordonouri O, Holder M, Remus K, Kieninger-Baum D, Wadien T, Danne T. \u201cLet the algorithm do the work\u201d: Reduction of hypoglycemia using sensor-augmented pump therapy with predictive insulin suspension (SmartGuard) in pediatric type 1 diabetes patients. Diabetes Technol Ther. 2017, 19:173-82. 10.1089\/dia.2016.0349","journal-title":"Diabetes Technol Ther"},{"key":"ref29","unstructured":"Decision Makers in Europe Further Expand Patient Access for Technology That Simplifies Diabetes Management. (2022). Accessed. 03\/15\/2023: https:\/\/news.medtronic.com\/Decision-makers-in-Europe-further-expand-patient-access-for-technology-that-simplifies-dia...."},{"key":"ref30","unstructured":"FDA Approves Medtronic MiniMed\u2122 780G System - World's First Insulin Pump With Meal Detection Technology* Featuring 5-Minute Auto Corrections\u2020\u00a7. (2020). Accessed. 04\/25\/2023: https:\/\/news.medtronic.com\/2023-04-21-FDA-Approves-Medtronic-MiniMed-TM-780G-System-Worlds-First-Insulin-Pump-with-Me...."}],"container-title":["Cureus"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cureus.com\/articles\/185344-tandem-tslim-x2-insulin-pump-use-in-clinical-practice-among-pregnant-individuals-with-type-1-diabetes-a-retrospective-observational-cohort-study","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,2,9]],"date-time":"2024-02-09T20:16:49Z","timestamp":1707509809000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cureus.com\/articles\/185344-tandem-tslim-x2-insulin-pump-use-in-clinical-practice-among-pregnant-individuals-with-type-1-diabetes-a-retrospective-observational-cohort-study"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,1,16]]},"references-count":30,"URL":"https:\/\/doi.org\/10.7759\/cureus.52369","relation":{},"ISSN":["2168-8184"],"issn-type":[{"value":"2168-8184","type":"print"}],"subject":[],"published":{"date-parts":[[2024,1,16]]}}}