{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,2,10]],"date-time":"2024-02-10T00:40:30Z","timestamp":1707525630214},"reference-count":12,"publisher":"Springer Science and Business Media LLC","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2024,1,19]]},"DOI":"10.7759\/cureus.52568","type":"journal-article","created":{"date-parts":[[2024,1,19]],"date-time":"2024-01-19T15:24:38Z","timestamp":1705677878000},"source":"Crossref","is-referenced-by-count":0,"title":["Autologous Chondrocyte Implantation With Collagen Membrane Using a Knotless Suture Bridge Technique"],"prefix":"10.7759","author":[{"given":"Toshihiro","family":"Seki","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kazushige","family":"Seki","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takashi","family":"Imagama","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tomoya","family":"Okazaki","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takashi","family":"Sakai","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1046\/j.1525-1594.2001.025003172.x","article-title":"Current concepts in tissue engineering technique for repair of cartilage defect","volume":"25","author":"Ochi M","year":"2001","unstructured":"Ochi M, Uchio Y, Tobita M, Kuriwaka M. Current concepts in tissue engineering technique for repair of cartilage defect. Artif Organs. 2001, 25:172-9. 10.1046\/j.1525-1594.2001.025003172.x","journal-title":"Artif Organs"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620x.84b4.11947","article-title":"Transplantation of cartilage-like tissue made by tissue engineering in the treatment of cartilage defects of the knee","volume":"84","author":"Ochi M","year":"2002","unstructured":"Ochi M, Uchio Y, Kawasaki K, Wakitani S, Iwasa J. Transplantation of cartilage-like tissue made by tissue engineering in the treatment of cartilage defects of the knee. J Bone Joint Surg Br. 2002, 84:571-8. 10.1302\/0301-620x.84b4.11947","journal-title":"J Bone Joint Surg Br"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1177\/1947603516638901","article-title":"Matrix-associated autologous chondrocyte implantation: a clinical follow-up at 15 years","volume":"7","author":"Gille J","year":"2016","unstructured":"Gille J, Behrens P, Schulz AP, Oheim R, Kienast B. Matrix-associated autologous chondrocyte implantation: a clinical follow-up at 15 years. Cartilage. 2016, 7:309-15. 10.1177\/1947603516638901","journal-title":"Cartilage"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1097\/JSA.0000000000000079","article-title":"Autologous chondrocyte implantation with collagen membrane","volume":"23","author":"Gillogly SD","year":"2015","unstructured":"Gillogly SD, Wheeler KS. Autologous chondrocyte implantation with collagen membrane. Sports Med Arthrosc Rev. 2015, 23:118-24. 10.1097\/JSA.0000000000000079","journal-title":"Sports Med Arthrosc Rev"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1016\/j.reth.2018.11.002","article-title":"Combined autologous chondrocyte implantation and meniscus reconstruction for large chondral defect in the lateral compartment due to discoid lateral meniscus tear: a case report","volume":"10","author":"Kato Y","year":"2019","unstructured":"Kato Y, Yamada S, Hattori S, Takazawa S, Ohuchi H. Combined autologous chondrocyte implantation and meniscus reconstruction for large chondral defect in the lateral compartment due to discoid lateral meniscus tear: a case report. Regen Ther. 2019, 10:64-8. 10.1016\/j.reth.2018.11.002","journal-title":"Regen Ther"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1016\/j.knee.2006.02.011","article-title":"A prospective, randomised study comparing two techniques of autologous chondrocyte implantation for osteochondral defects in the knee: periosteum covered versus type I\/III collagen covered","volume":"13","author":"Gooding CR","year":"2006","unstructured":"Gooding CR, Bartlett W, Bentley G, Skinner JA, Carrington R, Flanagan A. A prospective, randomised study comparing two techniques of autologous chondrocyte implantation for osteochondral defects in the knee: periosteum covered versus type I\/III collagen covered. Knee. 2006, 13:203-10. 10.1016\/j.knee.2006.02.011","journal-title":"Knee"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2019.02.028","article-title":"Arthroscopic rotator cuff repair with a knotless suture bridge technique: functional and radiological outcomes after a minimum follow-up of 5\u00a0years","volume":"35","author":"Dukan R","year":"2019","unstructured":"Dukan R, Ledinot P, Donadio J, Boyer P. Arthroscopic rotator cuff repair with a knotless suture bridge technique: functional and radiological outcomes after a minimum follow-up of 5\u00a0years. Arthroscopy. 2019, 35:2003-11. 10.1016\/j.arthro.2019.02.028","journal-title":"Arthroscopy"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1186\/s40634-021-00343-0","article-title":"A false-pouch closure technique with an intact superior peroneal retinaculum for recurrent dislocation of the peroneal tendon","volume":"8","author":"Matsui T","year":"2021","unstructured":"Matsui T, Kumai T, Shinohara Y, et al.. A false-pouch closure technique with an intact superior peroneal retinaculum for recurrent dislocation of the peroneal tendon. J Exp Orthop. 2021, 8:22. 10.1186\/s40634-021-00343-0","journal-title":"J Exp Orthop"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.1007\/s00402-011-1369-3","article-title":"Osteolysis after rotator cuff repair with bioabsorbable anchors","volume":"132","author":"Pilge H","year":"2012","unstructured":"Pilge H, Spang J, Rose T, Wolter H, Woertler K, Imhoff AB. Osteolysis after rotator cuff repair with bioabsorbable anchors. Arch Orthop Trauma Surg. 2012, 132:305-10. 10.1007\/s00402-011-1369-3","journal-title":"Arch Orthop Trauma Surg"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.1007\/s00167-020-06328-3","article-title":"Periimplant osteolysis does not affect the outcome of rotator cuff repair: a systematic review and meta-analysis","volume":"29","author":"Lee HY","year":"2021","unstructured":"Lee HY, Cheon SJ, Seo H, Lee BY, Nam JH, Lee DY. Periimplant osteolysis does not affect the outcome of rotator cuff repair: a systematic review and meta-analysis. Knee Surg Sports Traumatol Arthrosc. 2021, 29:3910-20. 10.1007\/s00167-020-06328-3","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.17.01169","article-title":"Glenoid bone reaction to all-soft suture anchors used for shoulder labral repairs","volume":"100","author":"Tompane T","year":"2018","unstructured":"Tompane T, Carney J, Wu WW, et al.. Glenoid bone reaction to all-soft suture anchors used for shoulder labral repairs. J Bone Joint Surg Am. 2018, 100:1223-9. 10.2106\/JBJS.17.01169","journal-title":"J Bone Joint Surg Am"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2019.03.032","article-title":"Perianchor cyst formation after arthroscopic rotator cuff repair using all-suture-type, bioabsorbable-type, and PEEK-type anchors","volume":"35","author":"Ro K","year":"2019","unstructured":"Ro K, Pancholi S, Son HS, Rhee YG. Perianchor cyst formation after arthroscopic rotator cuff repair using all-suture-type, bioabsorbable-type, and PEEK-type anchors. Arthroscopy. 2019, 35:2284-92. 10.1016\/j.arthro.2019.03.032","journal-title":"Arthroscopy"}],"container-title":["Cureus"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cureus.com\/articles\/221651-autologous-chondrocyte-implantation-with-collagen-membrane-using-a-knotless-suture-bridge-technique","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,2,9]],"date-time":"2024-02-09T20:12:07Z","timestamp":1707509527000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cureus.com\/articles\/221651-autologous-chondrocyte-implantation-with-collagen-membrane-using-a-knotless-suture-bridge-technique"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,1,19]]},"references-count":12,"URL":"https:\/\/doi.org\/10.7759\/cureus.52568","relation":{},"ISSN":["2168-8184"],"issn-type":[{"value":"2168-8184","type":"print"}],"subject":[],"published":{"date-parts":[[2024,1,19]]}}}