{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,2,10]],"date-time":"2024-02-10T00:44:05Z","timestamp":1707525845302},"reference-count":20,"publisher":"Springer Science and Business Media LLC","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2024,1,29]]},"DOI":"10.7759\/cureus.53197","type":"journal-article","created":{"date-parts":[[2024,1,30]],"date-time":"2024-01-30T05:14:35Z","timestamp":1706591675000},"source":"Crossref","is-referenced-by-count":0,"title":["Myocardial Infarction Simulated From Improper Telemetry (MISFIT): An Autobiographical Case Report"],"prefix":"10.7759","author":[{"given":"Philip R","family":"Cohen","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Brent M","family":"Gudenkauf","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajem.2023.10.009","article-title":"ECG lead misplacement in the frontal and horizontal plane mimicking a myocardial infarction","volume":"74","author":"Kaisbain N","year":"2023","unstructured":"Kaisbain N, Khoo KK, Lim WJ. ECG lead misplacement in the frontal and horizontal plane mimicking a myocardial infarction. Am J Emerg Med. 2023, 74:196.e1-4. 10.1016\/j.ajem.2023.10.009","journal-title":"Am J Emerg Med"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.7759\/cureus.9040","article-title":"Precordial ECG lead mispositioning: its incidence and estimated cost to healthcare","volume":"12","author":"Rehman M","year":"2020","unstructured":"Rehman M, Rehman NU. Precordial ECG lead mispositioning: its incidence and estimated cost to healthcare. Cureus. 2020, 12:e9040. 10.7759\/cureus.9040","journal-title":"Cureus"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajem.2018.02.006","article-title":"Misplacing V1 and V2 can have clinical consequences","volume":"36","author":"Walsh B","year":"2018","unstructured":"Walsh B. Misplacing V1 and V2 can have clinical consequences. Am J Emerg Med. 2018, 36:865-70. 10.1016\/j.ajem.2018.02.006","journal-title":"Am J Emerg Med"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1097\/TME.0000000000000381","article-title":"Reversal of fortune: ECG STEMI mimic","volume":"43","author":"Sweeney M","year":"2021","unstructured":"Sweeney M. Reversal of fortune: ECG STEMI mimic. Adv Emerg Nurs J. 2021, 43:303-8. 10.1097\/TME.0000000000000381","journal-title":"Adv Emerg Nurs J"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1016\/j.jelectrocard.2021.09.008","article-title":"The unusual case of a topsy-turvy ECG with a pseudo-infarct pattern","volume":"69","author":"Raut K","year":"2021","unstructured":"Raut K, Ghosh A, Kapoor A. The unusual case of a topsy-turvy ECG with a pseudo-infarct pattern. J Electrocardiol. 2021, 69:93-5. 10.1016\/j.jelectrocard.2021.09.008","journal-title":"J Electrocardiol"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1016\/j.jemermed.2012.02.024","article-title":"Electrocardiographic electrode misplacement, misconnection, and artifact","volume":"43","author":"Harrigan RA","year":"2012","unstructured":"Harrigan RA, Chan TC, Brady WJ. Electrocardiographic electrode misplacement, misconnection, and artifact. J Emerg Med. 2012, 43:1038-44. 10.1016\/j.jemermed.2012.02.024","journal-title":"J Emerg Med"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1016\/j.amjmed.2011.04.023","article-title":"Importance of recognizing pseudo-septal infarction due to electrocardiographic lead misplacement","volume":"125","author":"Ilg KJ","year":"2012","unstructured":"Ilg KJ, Lehmann MH. Importance of recognizing pseudo-septal infarction due to electrocardiographic lead misplacement. Am J Med. 2012, 125:23-7. 10.1016\/j.amjmed.2011.04.023","journal-title":"Am J Med"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajem.2003.08.007","article-title":"Influence of electrode misplacement on the electrocardiographic signs of inferior myocardial ischemia","volume":"21","author":"Rudiger A","year":"2003","unstructured":"Rudiger A, Sch\u00f6b L, Follath F. Influence of electrode misplacement on the electrocardiographic signs of inferior myocardial ischemia. Am J Emerg Med. 2003, 21:574-7. 10.1016\/j.ajem.2003.08.007","journal-title":"Am J Emerg Med"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.1016\/0735-6757(93)90177-d","article-title":"Recognition of electrocardiographic lead misplacements","volume":"11","author":"Peberdy MA","year":"1993","unstructured":"Peberdy MA, Ornato JP. Recognition of electrocardiographic lead misplacements. Am J Emerg Med. 1993, 11:403-5. 10.1016\/0735-6757(93)90177-d","journal-title":"Am J Emerg Med"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.7759\/cureus.25253","article-title":"Lumbar stenosis spinal surgery-associated cerebrospinal fluid leak without headache: an autobiographical case report","volume":"14","author":"Cohen PR","year":"2022","unstructured":"Cohen PR, Dorros SM. Lumbar stenosis spinal surgery-associated cerebrospinal fluid leak without headache: an autobiographical case report. Cureus. 2022, 14:e25253. 10.7759\/cureus.25253","journal-title":"Cureus"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1001\/jamainternmed.2022.6944","article-title":"Incorrect ECG diagnoses?-follow the leads","volume":"183","author":"Xin X","year":"2023","unstructured":"Xin X, Li X, Xin Q. Incorrect ECG diagnoses?-follow the leads. JAMA Intern Med. 2023, 183:484-5. 10.1001\/jamainternmed.2022.6944","journal-title":"JAMA Intern Med"},{"key":"ref12","article-title":"Morphologies suggestive of V1 and V2 lead misplacement","volume":"61","author":"Garc\u00eda-Niebla J","year":"2008","unstructured":"Garc\u00eda-Niebla J. Morphologies suggestive of V1 and V2 lead misplacement. Rev Esp Cardiol. 2008, 61:1109-10.","journal-title":"Rev Esp Cardiol"},{"key":"ref13","article-title":"Importance of accurate placement of precordial leads in the 12-lead electrocardiogram","volume":"16","author":"Hill NE","year":"1987","unstructured":"Hill NE, Goodman JS. Importance of accurate placement of precordial leads in the 12-lead electrocardiogram. Heart Lung. 1987, 16:561-6.","journal-title":"Heart Lung"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.1111\/j.1742-1241.2007.01390..x","article-title":"Accuracy in ECG lead placement among technicians, nurses, general physicians and cardiologists","volume":"62","author":"Rajaganeshan R","year":"2008","unstructured":"Rajaganeshan R, Ludlam CL, Francis DP, Parasramka SV, Sutton R. Accuracy in ECG lead placement among technicians, nurses, general physicians and cardiologists. Int J Clin Pract. 2008, 62:65-70. 10.1111\/j.1742-1241.2007.01390..x","journal-title":"Int J Clin Pract"},{"key":"ref15","doi-asserted-by":"publisher","DOI":"10.1016\/s0022-0736(96)80080-x","article-title":"Variability of precordial electrode placement during routine electrocardiography","volume":"29","author":"Wenger W","year":"1996","unstructured":"Wenger W, Kligfield P. Variability of precordial electrode placement during routine electrocardiography. J Electrocardiol. 1996, 29:179-84. 10.1016\/s0022-0736(96)80080-x","journal-title":"J Electrocardiol"},{"key":"ref16","doi-asserted-by":"publisher","DOI":"10.1053\/ajem.2001.25776","article-title":"Prominent R wave in lead V1: electrocardiographic differential diagnosis","volume":"19","author":"Mattu A","year":"2001","unstructured":"Mattu A, Brady WJ, Perron AD, Robinson DA. Prominent R wave in lead V1: electrocardiographic differential diagnosis. Am J Emerg Med. 2001, 19:504-13. 10.1053\/ajem.2001.25776","journal-title":"Am J Emerg Med"},{"key":"ref17","article-title":"Myocardial infarction or technical artifact?","volume":"38","author":"MacKenzie R","year":"2006","unstructured":"MacKenzie R. Myocardial infarction or technical artifact?. J Insur Med. 2006, 38:289-92.","journal-title":"J Insur Med"},{"key":"ref18","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajem.2006.06.018","article-title":"Electrocardiographic artifacts due to electrode misplacement and their frequency in different clinical settings","volume":"25","author":"Rudiger A","year":"2007","unstructured":"Rudiger A, Hellermann JP, Mukherjee R, Follath F, Turina J. Electrocardiographic artifacts due to electrode misplacement and their frequency in different clinical settings. Am J Emerg Med. 2007, 25:174-8. 10.1016\/j.ajem.2006.06.018","journal-title":"Am J Emerg Med"},{"key":"ref19","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejim.2012.03.011","article-title":"The effects of electrode misplacement on clinicians' interpretation of the standard 12-lead electrocardiogram","volume":"23","author":"Bond RR","year":"2012","unstructured":"Bond RR, Finlay DD, Nugent CD, Breen C, Guldenring D, Daly MJ. The effects of electrode misplacement on clinicians' interpretation of the standard 12-lead electrocardiogram. Eur J Intern Med. 2012, 23:610-5. 10.1016\/j.ejim.2012.03.011","journal-title":"Eur J Intern Med"},{"key":"ref20","doi-asserted-by":"publisher","DOI":"10.1016\/j.jelectrocard.2020.08.013","article-title":"Machine learning techniques for detecting electrode misplacement and interchanges when recording ECGs: a systematic review and meta-analysis","volume":"62","author":"Rjoob K","year":"2020","unstructured":"Rjoob K, Bond R, Finlay D, et al.. Machine learning techniques for detecting electrode misplacement and interchanges when recording ECGs: a systematic review and meta-analysis. J Electrocardiol. 2020, 62:116-23. 10.1016\/j.jelectrocard.2020.08.013","journal-title":"J Electrocardiol"}],"container-title":["Cureus"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cureus.com\/articles\/225232-myocardial-infarction-simulated-from-improper-telemetry-misfit-an-autobiographical-case-report","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,2,9]],"date-time":"2024-02-09T20:14:55Z","timestamp":1707509695000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cureus.com\/articles\/225232-myocardial-infarction-simulated-from-improper-telemetry-misfit-an-autobiographical-case-report"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,1,29]]},"references-count":20,"URL":"https:\/\/doi.org\/10.7759\/cureus.53197","relation":{},"ISSN":["2168-8184"],"issn-type":[{"value":"2168-8184","type":"print"}],"subject":[],"published":{"date-parts":[[2024,1,29]]}}}