{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,2,15]],"date-time":"2024-02-15T00:42:58Z","timestamp":1707957778441},"reference-count":27,"publisher":"Springer Science and Business Media LLC","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2024,2,14]]},"DOI":"10.7759\/cureus.54203","type":"journal-article","created":{"date-parts":[[2024,2,14]],"date-time":"2024-02-14T22:41:46Z","timestamp":1707950506000},"source":"Crossref","is-referenced-by-count":0,"title":["Utility of Echo Planar Imaging With Compressed Sensing-Sensitivity Encoding (EPICS) for the Evaluation of the Head and Neck Region"],"prefix":"10.7759","author":[{"given":"Yuya","family":"Hirano","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Noriyuki","family":"Fujima","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kinya","family":"Ishizaka","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takuya","family":"Aoike","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Junichi","family":"Nakagawa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Masami","family":"Yoneyama","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kohsuke","family":"Kudo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1148\/rg.337125163","article-title":"Functional imaging for radiation treatment planning, response assessment, and adaptive therapy in head and neck cancer","volume":"33","author":"Bhatnagar P","year":"2013","unstructured":"Bhatnagar P, Subesinghe M, Patel C, Prestwich R, Scarsbrook AF. Functional imaging for radiation treatment planning, response assessment, and adaptive therapy in head and neck cancer. Radiographics. 2013, 33:1909-29. 10.1148\/rg.337125163","journal-title":"Radiographics"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1186\/s40644-016-0080-6","article-title":"Functional MRI for the prediction of treatment response in head and neck squamous cell carcinoma: potential and limitations","volume":"16","author":"King AD","year":"2016","unstructured":"King AD, Thoeny HC. Functional MRI for the prediction of treatment response in head and neck squamous cell carcinoma: potential and limitations. Cancer Imaging. 2016, 16:23. 10.1186\/s40644-016-0080-6","journal-title":"Cancer Imaging"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1016\/j.mric.2017.08.011","article-title":"Diffusion-weighted imaging in head and neck cancer: technique, limitations, and applications","volume":"26","author":"Connolly M","year":"2018","unstructured":"Connolly M, Srinivasan A. Diffusion-weighted imaging in head and neck cancer: technique, limitations, and applications. Magn Reson Imaging Clin N Am. 2018, 26:121-33. 10.1016\/j.mric.2017.08.011","journal-title":"Magn Reson Imaging Clin N Am"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1177\/1971400918808546","article-title":"Functional magnetic resonance imaging of head and neck cancer: performance and potential","volume":"32","author":"El Beltagi AH","year":"2019","unstructured":"El Beltagi AH, Elsotouhy AH, Own AM, Abdelfattah W, Nair K, Vattoth S. Functional magnetic resonance imaging of head and neck cancer: performance and potential. Neuroradiol J. 2019, 32:36-52. 10.1177\/1971400918808546","journal-title":"Neuroradiol J"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.21037\/qims.2018.10.14","article-title":"Quantitative diffusion magnetic resonance imaging in head and neck tumors","volume":"8","author":"Payabvash S","year":"2018","unstructured":"Payabvash S. Quantitative diffusion magnetic resonance imaging in head and neck tumors. Quant Imaging Med Surg. 2018, 8:1052-65. 10.21037\/qims.2018.10.14","journal-title":"Quant Imaging Med Surg"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1016\/j.nic.2020.04.001","article-title":"Diffusion MR imaging in the head and neck: principles and applications","volume":"30","author":"Norris CD","year":"2020","unstructured":"Norris CD, Quick SE, Parker JG, Koontz NA. Diffusion MR imaging in the head and neck: principles and applications. Neuroimaging Clin N Am. 2020, 30:261-82. 10.1016\/j.nic.2020.04.001","journal-title":"Neuroimaging Clin N Am"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1016\/j.mric.2021.01.005","article-title":"Diffusion-weighted imaging of the head and neck (including temporal bone)","volume":"29","author":"Boucher F","year":"2021","unstructured":"Boucher F, Liao E, Srinivasan A. Diffusion-weighted imaging of the head and neck (including temporal bone). Magn Reson Imaging Clin N Am. 2021, 29:205-32. 10.1016\/j.mric.2021.01.005","journal-title":"Magn Reson Imaging Clin N Am"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A2949","article-title":"Diffusion-weighted MR imaging in head and neck cancer: comparison between half-fourier acquired single-shot turbo spin-echo and EPI techniques","volume":"33","author":"Verhappen MH","year":"2012","unstructured":"Verhappen MH, Pouwels PJ, Ljumanovic R, van der Putten L, Knol DL, De Bree R, Castelijns JA. Diffusion-weighted MR imaging in head and neck cancer: comparison between half-fourier acquired single-shot turbo spin-echo and EPI techniques. AJNR Am J Neuroradiol. 2012, 33:1239-46. 10.3174\/ajnr.A2949","journal-title":"AJNR Am J Neuroradiol"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.1148\/rg.342135051","article-title":"MR imaging artifacts and parallel imaging techniques with calibration scanning: a new twist on old problems","volume":"34","author":"Yanasak NE","year":"2014","unstructured":"Yanasak NE, Kelly MJ. MR imaging artifacts and parallel imaging techniques with calibration scanning: a new twist on old problems. Radiographics. 2014, 34:532-48. 10.1148\/rg.342135051","journal-title":"Radiographics"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.1007\/s00330-017-4990-x","article-title":"Comparison of intravoxel incoherent motion diffusion-weighted imaging between turbo spin-echo and echo-planar imaging of the head and neck","volume":"28","author":"Mikayama R","year":"2018","unstructured":"Mikayama R, Yabuuchi H, Sonoda S, et al.. Comparison of intravoxel incoherent motion diffusion-weighted imaging between turbo spin-echo and echo-planar imaging of the head and neck. Eur Radiol. 2018, 28:316-24. 10.1007\/s00330-017-4990-x","journal-title":"Eur Radiol"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1097\/MD.0000000000010447","article-title":"Comparison of the image quality of turbo spin echo- and echo-planar diffusion-weighted images of the oral cavity","volume":"97","author":"Hirata K","year":"2018","unstructured":"Hirata K, Nakaura T, Okuaki T, et al.. Comparison of the image quality of turbo spin echo- and echo-planar diffusion-weighted images of the oral cavity. Medicine (Baltimore). 2018, 97:0447. 10.1097\/MD.0000000000010447","journal-title":"Medicine (Baltimore)"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A4114","article-title":"Diffusion-weighted imaging of the head and neck in healthy subjects: reproducibility of ADC values in different MRI systems and repeat sessions","volume":"36","author":"Kolff-Gart AS","year":"2015","unstructured":"Kolff-Gart AS, Pouwels PJ, Noij DP, et al.. Diffusion-weighted imaging of the head and neck in healthy subjects: reproducibility of ADC values in different MRI systems and repeat sessions. AJNR Am J Neuroradiol. 2015, 36:384-90. 10.3174\/ajnr.A4114","journal-title":"AJNR Am J Neuroradiol"},{"key":"ref13","article-title":"Noise reduction in prostate single-shot DW-EPI utilizing compressed SENSE framework","author":"Yoneyama M","year":"2019","unstructured":"Yoneyama M, Morita K, Peeters J, Nakaura T, Van Cauteren M. Noise reduction in prostate single-shot DW-EPI utilizing compressed SENSE framework. ISMRM. 2019,","journal-title":"ISMRM"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2021.109889","article-title":"Diffusion-weighted imaging of the abdomen using echo planar imaging with compressed SENSE: Feasibility, image quality, and ADC value evaluation","volume":"142","author":"Kaga T","year":"2021","unstructured":"Kaga T, Noda Y, Mori T, et al.. Diffusion-weighted imaging of the abdomen using echo planar imaging with compressed SENSE: Feasibility, image quality, and ADC value evaluation. Eur J Radiol. 2021, 142:109889. 10.1016\/j.ejrad.2021.109889","journal-title":"Eur J Radiol"},{"key":"ref15","doi-asserted-by":"publisher","DOI":"10.1007\/s10334-022-01010-w","article-title":"Clinical application of single-shot echo-planar diffusion-weighted imaging with compressed SENSE in prostate MRI at 3T: preliminary experience","volume":"35","author":"Tamada T","year":"2022","unstructured":"Tamada T, Ueda Y, Kido A, et al.. Clinical application of single-shot echo-planar diffusion-weighted imaging with compressed SENSE in prostate MRI at 3T: preliminary experience. MAGMA. 2022, 35:549-56. 10.1007\/s10334-022-01010-w","journal-title":"MAGMA"},{"key":"ref16","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2022.110489","article-title":"Echo planar imaging with compressed sensitivity encoding (EPICS): usefulness for head and neck diffusion-weighted MRI","volume":"155","author":"Yoshida N","year":"2022","unstructured":"Yoshida N, Nakaura T, Morita K, et al.. Echo planar imaging with compressed sensitivity encoding (EPICS): usefulness for head and neck diffusion-weighted MRI. Eur J Radiol. 2022, 155:110489. 10.1016\/j.ejrad.2022.110489","journal-title":"Eur J Radiol"},{"key":"ref17","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.22161","article-title":"Accelerating SENSE using compressed sensing","volume":"62","author":"Liang D","year":"2009","unstructured":"Liang D, Liu B, Wang J, Ying L. Accelerating SENSE using compressed sensing. Magn Reson Med. 2009, 62:1574-84. 10.1002\/mrm.22161","journal-title":"Magn Reson Med"},{"key":"ref18","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A5905","article-title":"Compressed sensing-sensitivity encoding (CS-sense) accelerated brain imaging: reduced scan time without reduced image quality","volume":"40","author":"Vranic JE","year":"2019","unstructured":"Vranic JE, Cross NM, Wang Y, Hippe DS, de Weerdt E, Mossa-Basha M. Compressed sensing-sensitivity encoding (CS-sense) accelerated brain imaging: reduced scan time without reduced image quality. AJNR Am J Neuroradiol. 2019, 40:92-8. 10.3174\/ajnr.A5905","journal-title":"AJNR Am J Neuroradiol"},{"key":"ref19","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0214887","article-title":"Reduction of procedure times in routine clinical practice with compressed SENSE magnetic resonance imaging technique","volume":"14","author":"Sartoretti E","year":"2019","unstructured":"Sartoretti E, Sartoretti T, Binkert C, et al.. Reduction of procedure times in routine clinical practice with compressed SENSE magnetic resonance imaging technique. PLoS One. 2019, 14:0214887. 10.1371\/journal.pone.0214887","journal-title":"PLoS One"},{"key":"ref20","doi-asserted-by":"publisher","DOI":"10.1097\/MD.0000000000033639","article-title":"Clinical utility of single-shot echo-planar diffusion-weighted imaging using L1-regularized iterative sensitivity encoding in prostate MRI","volume":"102","author":"Nishioka N","year":"2023","unstructured":"Nishioka N, Fujima N, Tsuneta S, et al.. Clinical utility of single-shot echo-planar diffusion-weighted imaging using L1-regularized iterative sensitivity encoding in prostate MRI. Medicine (Baltimore). 2023, 102:33639. 10.1097\/MD.0000000000033639","journal-title":"Medicine (Baltimore)"},{"key":"ref21","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejro.2023.100516","article-title":"Reproducibility of quantitative ADC, T1, and T2 measurement on the cerebral cortex: utility of whole brain echo-planar DWI with compressed SENSE (EPICS-DWI): A pilot study","volume":"11","author":"Yamashita K","year":"2023","unstructured":"Yamashita K, Yoneyama M, Kikuchi K, et al.. Reproducibility of quantitative ADC, T1, and T2 measurement on the cerebral cortex: utility of whole brain echo-planar DWI with compressed SENSE (EPICS-DWI): A pilot study. Eur J Radiol Open. 2023, 11:100516. 10.1016\/j.ejro.2023.100516","journal-title":"Eur J Radiol Open"},{"key":"ref22","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2023.111059","article-title":"Diagnostic ability of diffusion-weighted imaging using echo planar imaging with compressed SENSE (EPICS) for differentiating hepatic hemangioma and liver metastasis","volume":"167","author":"Kaga T","year":"2023","unstructured":"Kaga T, Noda Y, Asano M, et al.. Diagnostic ability of diffusion-weighted imaging using echo planar imaging with compressed SENSE (EPICS) for differentiating hepatic hemangioma and liver metastasis. Eur J Radiol. 2023, 167:111059. 10.1016\/j.ejrad.2023.111059","journal-title":"Eur J Radiol"},{"key":"ref23","doi-asserted-by":"publisher","DOI":"10.1259\/bjr.20200825","article-title":"Single shot echo planar imaging (ssEPI) vs single shot turbo spin echo (ssTSE) DWI of the orbit in patients with ocular melanoma","volume":"94","author":"Gumeler E","year":"2021","unstructured":"Gumeler E, Parlak S, Yazici G, Karabulut E, Kiratli H, Oguz KK. Single shot echo planar imaging (ssEPI) vs single shot turbo spin echo (ssTSE) DWI of the orbit in patients with ocular melanoma. Br J Radiol. 2021, 94:20200825. 10.1259\/bjr.20200825","journal-title":"Br J Radiol"},{"key":"ref24","doi-asserted-by":"publisher","DOI":"10.1148\/radiographics.21.3.g01ma23767","article-title":"Principles and applications of echo-planar imaging: a review for the general radiologist","volume":"21","author":"Poustchi-Amin M","year":"2001","unstructured":"Poustchi-Amin M, Mirowitz SA, Brown JJ, McKinstry RC, Li T. Principles and applications of echo-planar imaging: a review for the general radiologist. Radiographics. 2001, 21:767-79. 10.1148\/radiographics.21.3.g01ma23767","journal-title":"Radiographics"},{"key":"ref25","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.23639","article-title":"Parallel MR imaging","volume":"36","author":"Deshmane A","year":"2012","unstructured":"Deshmane A, Gulani V, Griswold MA, Seiberlich N. Parallel MR imaging. J Magn Reson Imaging. 2012, 36:55-72. 10.1002\/jmri.23639","journal-title":"J Magn Reson Imaging"},{"key":"ref26","doi-asserted-by":"publisher","DOI":"10.1007\/s10334-023-01129-4","article-title":"Improvement of image quality in diffusion-weighted imaging with model-based deep learning reconstruction for evaluations of the head and neck","author":"Fujima N","year":"2023","unstructured":"Fujima N, Nakagawa J, Kameda H, et al.. Improvement of image quality in diffusion-weighted imaging with model-based deep learning reconstruction for evaluations of the head and neck. MAGMA. 2023, 10.1007\/s10334-023-01129-4","journal-title":"MAGMA"},{"key":"ref27","doi-asserted-by":"publisher","DOI":"10.2463\/mrms.rev.2023-0047","article-title":"Current state of artificial intelligence in clinical applications for head and neck MR imaging","volume":"22","author":"Fujima N","year":"2023","unstructured":"Fujima N, Kamagata K, Ueda D, et al.. Current state of artificial intelligence in clinical applications for head and neck MR imaging. Magn Reson Med Sci. 2023, 22:401-14. 10.2463\/mrms.rev.2023-0047","journal-title":"Magn Reson Med Sci"}],"container-title":["Cureus"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cureus.com\/articles\/229035-utility-of-echo-planar-imaging-with-compressed-sensing-sensitivity-encoding-epics-for-the-evaluation-of-the-head-and-neck-region","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,2,14]],"date-time":"2024-02-14T22:41:48Z","timestamp":1707950508000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cureus.com\/articles\/229035-utility-of-echo-planar-imaging-with-compressed-sensing-sensitivity-encoding-epics-for-the-evaluation-of-the-head-and-neck-region"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,2,14]]},"references-count":27,"URL":"https:\/\/doi.org\/10.7759\/cureus.54203","relation":{},"ISSN":["2168-8184"],"issn-type":[{"value":"2168-8184","type":"print"}],"subject":[],"published":{"date-parts":[[2024,2,14]]}}}