{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,5]],"date-time":"2025-12-05T12:28:22Z","timestamp":1764937702902},"reference-count":14,"publisher":"Springer Science and Business Media LLC","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2024,3,7]]},"DOI":"10.7759\/cureus.55716","type":"journal-article","created":{"date-parts":[[2024,3,7]],"date-time":"2024-03-07T12:26:51Z","timestamp":1709814411000},"source":"Crossref","is-referenced-by-count":3,"title":["Secondary Angle Closure Caused by Anterior Displacement of Capsular Tension Ring and Intraocular Lens Due to Aqueous Misdirection"],"prefix":"10.7759","author":[{"given":"Kensuke","family":"Goto","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ryo","family":"Tomita","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jiro","family":"Hiraiwa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mitsuki","family":"Kawabe","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Koji M","family":"Nishiguchi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kenya","family":"Yuki","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","reference":[{"key":"ref1","article-title":"\u201cEquator ring\u201d for maintenance of the completely circular contour of the capsular bag equator after cataract removal","volume":"22","author":"Hara T","year":"1991","unstructured":"Hara T, Hara T, Yamada Y. \u201cEquator ring\u201d for maintenance of the completely circular contour of the capsular bag equator after cataract removal. Ophthalmic Surg. 1991, 22:358-9.","journal-title":"Ophthalmic Surg"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1016\/s0886-3350(13)80177-0","article-title":"A ring to support the capsular bag after continuous curvilinear capsulorhexis","volume":"20","author":"Nagamoto T","year":"1994","unstructured":"Nagamoto T, Bissen-Miyajima H. A ring to support the capsular bag after continuous curvilinear capsulorhexis. J Cataract Refract Surg. 1994, 20:417-20. 10.1016\/s0886-3350(13)80177-0","journal-title":"J Cataract Refract Surg"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1016\/s0886-3350(00)00446-6","article-title":"The capsular tension ring: designs, applications, and techniques","volume":"26","author":"Menapace R","year":"2000","unstructured":"Menapace R, Findl O, Georgopoulos M, Rainer G, Vass C, Schmetterer K. The capsular tension ring: designs, applications, and techniques. J Cataract Refract Surg. 2000, 26:898-912. 10.1016\/s0886-3350(00)00446-6","journal-title":"J Cataract Refract Surg"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2011.08.016","article-title":"In-the-bag capsular tension ring and intraocular lens subluxation or dislocation: a series of 23 cases","volume":"119","author":"Werner L","year":"2012","unstructured":"Werner L, Zaugg B, Neuhann T, Burrow M, Tetz M. In-the-bag capsular tension ring and intraocular lens subluxation or dislocation: a series of 23 cases. Ophthalmology. 2012, 119:266-71. 10.1016\/j.ophtha.2011.08.016","journal-title":"Ophthalmology"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2006.05.016","article-title":"Dislocation of capsular bag with intraocular lens and capsular tension ring","volume":"32","author":"Oner FH","year":"2006","unstructured":"Oner FH, Kocak N, Saatci AO. Dislocation of capsular bag with intraocular lens and capsular tension ring. J Cataract Refract Surg. 2006, 32:1756-8. 10.1016\/j.jcrs.2006.05.016","journal-title":"J Cataract Refract Surg"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2006.01.077","article-title":"Management of posteriorly dislocated endocapsular tension ring and intraocular lens complex","volume":"32","author":"Deka S","year":"2006","unstructured":"Deka S, Deka A, Bhattacharjee H. Management of posteriorly dislocated endocapsular tension ring and intraocular lens complex. J Cataract Refract Surg. 2006, 32:887-9. 10.1016\/j.jcrs.2006.01.077","journal-title":"J Cataract Refract Surg"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1097\/IJG.0000000000000780","article-title":"Chronic and intermittent angle closure caused by in-the-bag capsular tension ring and intraocular lens dislocation in patients with pseudoexfoliation syndrome","volume":"26","author":"Bochmann F","year":"2017","unstructured":"Bochmann F, St\u00fcrmer J. Chronic and intermittent angle closure caused by in-the-bag capsular tension ring and intraocular lens dislocation in patients with pseudoexfoliation syndrome. J Glaucoma. 2017, 26:1051-5. 10.1097\/IJG.0000000000000780","journal-title":"J Glaucoma"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(16)30956-4","article-title":"Effectiveness of early lens extraction for the treatment of primary angle-closure glaucoma (EAGLE): a randomised controlled trial","volume":"388","author":"Azuara-Blanco A","year":"2016","unstructured":"Azuara-Blanco A, Burr J, Ramsay C, et al.. Effectiveness of early lens extraction for the treatment of primary angle-closure glaucoma (EAGLE): a randomised controlled trial. Lancet. 2016, 388:1389-97. 10.1016\/S0140-6736(16)30956-4","journal-title":"Lancet"},{"key":"ref9","article-title":"Management of zonular dialysis in phacoemulsification and IOL implantation using the capsular tension ring","volume":"28","author":"Gimbel H V","year":"1997","unstructured":"Gimbel H V, Sun R, Heston JP. Management of zonular dialysis in phacoemulsification and IOL implantation using the capsular tension ring. Ophthalmic Surg Lasers. 1997, 28:273-81.","journal-title":"Ophthalmic Surg Lasers"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.1007\/s00417-017-3837-0","article-title":"Acute and chronic fluid misdirection syndrome: pathophysiology and treatment","volume":"256","author":"Grzybowski A","year":"2018","unstructured":"Grzybowski A, Kanclerz P. Acute and chronic fluid misdirection syndrome: pathophysiology and treatment. Graefes Arch Clin Exp Ophthalmol. 2018, 256:135-54. 10.1007\/s00417-017-3837-0","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1097\/MD.0000000000018836","article-title":"One-year outcome of low dose laser cyclophotocoagulation for capsular tension ring-induced malignant glaucoma: a case report","volume":"99","author":"Lin H","year":"2020","unstructured":"Lin H, Zhou G, Zhang S, Huang F, Liang Y. One-year outcome of low dose laser cyclophotocoagulation for capsular tension ring-induced malignant glaucoma: a case report. Medicine (Baltimore). 2020, 99:e18836. 10.1097\/MD.0000000000018836","journal-title":"Medicine (Baltimore)"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1186\/s12886-016-0226-0","article-title":"Angle closure caused by a plateau-like iris associated with an enlarged Soemmering's ring: a case report","volume":"16","author":"Kitamura F","year":"2016","unstructured":"Kitamura F, Inoue T, Kuroda U, Tanihara H. Angle closure caused by a plateau-like iris associated with an enlarged Soemmering's ring: a case report. BMC Ophthalmol. 2016, 16:49. 10.1186\/s12886-016-0226-0","journal-title":"BMC Ophthalmol"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-021-93293-7","article-title":"Association of peripheral anterior synechiae with anterior segment parameters in eyes with primary angle closure glaucoma","volume":"11","author":"Loo Y","year":"2021","unstructured":"Loo Y, Tun TA, Vithana EN, et al.. Association of peripheral anterior synechiae with anterior segment parameters in eyes with primary angle closure glaucoma. Sci Rep. 2021, 11:13906. 10.1038\/s41598-021-93293-7","journal-title":"Sci Rep"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.1007\/s00417-011-1763-0","article-title":"Outcomes of different management options for malignant glaucoma: a retrospective study","volume":"250","author":"Debrouwere V","year":"2012","unstructured":"Debrouwere V, Stalmans P, Van Calster J, Spileers W, Zeyen T, Stalmans I. Outcomes of different management options for malignant glaucoma: a retrospective study. Graefes Arch Clin Exp Ophthalmol. 2012, 250:131-41. 10.1007\/s00417-011-1763-0","journal-title":"Graefes Arch Clin Exp Ophthalmol"}],"container-title":["Cureus"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cureus.com\/articles\/223180-secondary-angle-closure-caused-by-anterior-displacement-of-capsular-tension-ring-and-intraocular-lens-due-to-aqueous-misdirection","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,3,7]],"date-time":"2024-03-07T12:26:54Z","timestamp":1709814414000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cureus.com\/articles\/223180-secondary-angle-closure-caused-by-anterior-displacement-of-capsular-tension-ring-and-intraocular-lens-due-to-aqueous-misdirection"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,3,7]]},"references-count":14,"URL":"https:\/\/doi.org\/10.7759\/cureus.55716","relation":{},"ISSN":["2168-8184"],"issn-type":[{"value":"2168-8184","type":"print"}],"subject":[],"published":{"date-parts":[[2024,3,7]]}}}