{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,19]],"date-time":"2026-02-19T03:47:43Z","timestamp":1771472863904,"version":"3.50.1"},"reference-count":9,"publisher":"Springer Science and Business Media LLC","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2024,4,18]]},"DOI":"10.7759\/cureus.58530","type":"journal-article","created":{"date-parts":[[2024,4,18]],"date-time":"2024-04-18T14:29:57Z","timestamp":1713450597000},"source":"Crossref","is-referenced-by-count":1,"title":["First Experience With the Utility of ReMAP (Repeatable Microcatheter Access Port) in Portal Vein Stenting"],"prefix":"10.7759","author":[{"given":"Kentaro","family":"Fujimoto","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takayuki","family":"Kondo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hidemi","family":"Unozawa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jun","family":"Koizumi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Naoya","family":"Kato","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1097\/00000658-198508000-00009","article-title":"Protean manifestations of pylethrombosis. A review of thirty-four patients","volume":"202","author":"Witte CL","year":"1985","unstructured":"Witte CL, Brewer ML, Witte MH, Pond GB. Protean manifestations of pylethrombosis. A review of thirty-four patients. Ann Surg. 1985, 202:191-202. 10.1097\/00000658-198508000-00009","journal-title":"Ann Surg"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1111\/apt.13019","article-title":"Review article: portal vein obstruction--epidemiology, pathogenesis, natural history, prognosis and treatment","volume":"41","author":"Kumar A","year":"2015","unstructured":"Kumar A, Sharma P, Arora A. Review article: portal vein obstruction--epidemiology, pathogenesis, natural history, prognosis and treatment. Aliment Pharmacol Ther. 2015, 41:276-92. 10.1111\/apt.13019","journal-title":"Aliment Pharmacol Ther"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1055\/s-2002-23206","article-title":"Extrahepatic portal vein obstruction","volume":"22","author":"Sarin SK","year":"2002","unstructured":"Sarin SK, Agarwal SR. Extrahepatic portal vein obstruction. Semin Liver Dis. 2002, 22:43-58. 10.1055\/s-2002-23206","journal-title":"Semin Liver Dis"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1148\/radiology.220.1.r01jl03150","article-title":"Portal venous stent placement in patients with pancreatic and biliary neoplasms invading portal veins and causing portal hypertension: initial experience","volume":"220","author":"Yamakado K","year":"2001","unstructured":"Yamakado K, Nakatsuka A, Tanaka N, Fujii A, Isaji S, Kawarada Y, Takeda K. Portal venous stent placement in patients with pancreatic and biliary neoplasms invading portal veins and causing portal hypertension: initial experience. Radiology. 2001, 220:150-6. 10.1148\/radiology.220.1.r01jl03150","journal-title":"Radiology"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.3748\/wjg.v11.i21.3315","article-title":"Portal venous stent placement for treatment of portal hypertension caused by benign main portal vein stenosis","volume":"11","author":"Shan H","year":"2005","unstructured":"Shan H, Xiao XS, Huang MS, Ouyang Q, Jiang ZB. Portal venous stent placement for treatment of portal hypertension caused by benign main portal vein stenosis. World J Gastroenterol. 2005, 11:3315-8. 10.3748\/wjg.v11.i21.3315","journal-title":"World J Gastroenterol"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1186\/s12893-017-0209-y","article-title":"Portal vein stent placement for the treatment of postoperative portal vein stenosis: long-term success and factor associated with stent failure","volume":"17","author":"Kato A","year":"2017","unstructured":"Kato A, Shimizu H, Ohtsuka M, Yoshitomi H, Furukawa K, Miyazaki M. Portal vein stent placement for the treatment of postoperative portal vein stenosis: long-term success and factor associated with stent failure. BMC Surg. 2017, 17:11. 10.1186\/s12893-017-0209-y","journal-title":"BMC Surg"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvir.2023.03.013","article-title":"Transjugular thrombolysis and stent-graft implantation for acute portal vein aneurysm thrombosis","volume":"34","author":"Wannhoff A","year":"2023","unstructured":"Wannhoff A, Riecken B, Caca K. Transjugular thrombolysis and stent-graft implantation for acute portal vein aneurysm thrombosis. J Vasc Interv Radiol. 2023, 34:1275-6. 10.1016\/j.jvir.2023.03.013","journal-title":"J Vasc Interv Radiol"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2021.109986","article-title":"Complications of transjugular intrahepatic portosystemic shunt (TIPS) in the era of the stent graft - what the interventionists need to know?","volume":"144","author":"Patel RK","year":"2021","unstructured":"Patel RK, Chandel K, Tripathy TP, Mukund A. Complications of transjugular intrahepatic portosystemic shunt (TIPS) in the era of the stent graft - what the interventionists need to know?. Eur J Radiol. 2021, 144:109986. 10.1016\/j.ejrad.2021.109986","journal-title":"Eur J Radiol"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.1097\/MD.0000000000027264","article-title":"Long term clinical outcomes of portal vein stenting for symptomatic portal vein stenosis after pancreaticoduodenectomy","volume":"100","author":"You Y","year":"2021","unstructured":"You Y, Heo JS, Han IW, et al.. Long term clinical outcomes of portal vein stenting for symptomatic portal vein stenosis after pancreaticoduodenectomy. Medicine (Baltimore). 2021, 100:e27264. 10.1097\/MD.0000000000027264","journal-title":"Medicine (Baltimore)"}],"container-title":["Cureus"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cureus.com\/articles\/226938-first-experience-with-the-utility-of-remap-repeatable-microcatheter-access-port-in-portal-vein-stenting","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,4,18]],"date-time":"2024-04-18T14:30:00Z","timestamp":1713450600000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cureus.com\/articles\/226938-first-experience-with-the-utility-of-remap-repeatable-microcatheter-access-port-in-portal-vein-stenting"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,4,18]]},"references-count":9,"URL":"https:\/\/doi.org\/10.7759\/cureus.58530","relation":{},"ISSN":["2168-8184"],"issn-type":[{"value":"2168-8184","type":"print"}],"subject":[],"published":{"date-parts":[[2024,4,18]]}}}