{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,4,21]],"date-time":"2024-04-21T00:33:21Z","timestamp":1713659601793},"reference-count":13,"publisher":"Springer Science and Business Media LLC","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2024,4,20]]},"DOI":"10.7759\/cureus.58629","type":"journal-article","created":{"date-parts":[[2024,4,20]],"date-time":"2024-04-20T09:37:08Z","timestamp":1713605828000},"source":"Crossref","is-referenced-by-count":0,"title":["Clinical Assessment of the Ambu\u00ae Aura-i\u2122 as an Independent Ventilatory Device and Conduit for Fiberoptic-Guided Endotracheal Intubation in Adults"],"prefix":"10.7759","author":[{"given":"Navya","family":"Mishra","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nitesh","family":"Sinha","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ramesh K","family":"Kharwar","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jay","family":"Prakash","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/55.8.801","article-title":"The laryngeal mask--a new concept in airway management","volume":"55","author":"Brain AI","year":"1983","unstructured":"Brain AI. The laryngeal mask--a new concept in airway management. Br J Anaesth. 1983, 55:801-805. 10.1093\/bja\/55.8.801","journal-title":"Br J Anaesth"},{"key":"ref2","article-title":"The development of the Laryngeal Mask--a brief history of the invention, early clinical studies and experimental work from which the Laryngeal Mask evolved","volume":"4","author":"Brain AI","year":"1991","unstructured":"Brain AI. The development of the Laryngeal Mask--a brief history of the invention, early clinical studies and experimental work from which the Laryngeal Mask evolved. Eur J Anaesthesiol Suppl. 1991, 4:5-17.","journal-title":"Eur J Anaesthesiol Suppl"},{"key":"ref3","unstructured":"Product information. Ambu Aura-i\u00ae Single use Laryngeal Mask Sterile use by trained clinicians only. http:\/\/www.ambuaurai.com."},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1155\/2016\/4717061","article-title":"The AMBU\u00ae Aura-i\u2122 Laryngeal Mask and LMA Supreme\u2122: a randomized trial of clinical performance and fibreoptic positioning in unparalysed, anaesthetised patients by novices","volume":"2016","author":"Yahaya Z","year":"2016","unstructured":"Yahaya Z, Teoh WH, Dintan NA, Agrawal R. The AMBU\u00ae Aura-i\u2122 Laryngeal Mask and LMA Supreme\u2122: a randomized trial of clinical performance and fibreoptic positioning in unparalysed, anaesthetised patients by novices. Anesthesiol Res Pract. 2016, 2016:4717061. 10.1155\/2016\/4717061","journal-title":"Anesthesiol Res Pract"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1111\/anae.12988","article-title":"A comparison of fibreoptic-guided tracheal intubation through the Ambu \u00ae Aura-i \u2122, the intubating laryngeal mask airway and the i-gel \u2122: a manikin study","volume":"70","author":"de Lloyd LJ","year":"2015","unstructured":"de Lloyd LJ, Subash F, Wilkes AR, Hodzovic I. A comparison of fibreoptic-guided tracheal intubation through the Ambu \u00ae Aura-i \u2122, the intubating laryngeal mask airway and the i-gel \u2122: a manikin study. Anaesthesia. 2015, 70:591-597. 10.1111\/anae.12988","journal-title":"Anaesthesia"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.4103\/IJCIIS.IJCIIS_11_19","article-title":"Clinical evaluation of Ambu(\u00ae) Aura-i\u2122 - A new intubating laryngeal mask airway as an independent ventilatory device and a conduit for tracheal intubation in pediatric patients","volume":"9","author":"Rangaswamy TM","year":"2019","unstructured":"Rangaswamy TM, Bharadwaj A, Jain P. Clinical evaluation of Ambu(\u00ae) Aura-i\u2122 - A new intubating laryngeal mask airway as an independent ventilatory device and a conduit for tracheal intubation in pediatric patients. Int J Crit Illn Inj Sci. 2019, 9:157-163. 10.4103\/IJCIIS.IJCIIS_11_19","journal-title":"Int J Crit Illn Inj Sci"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1111\/anae.13330","article-title":"A randomised comparison of the Ambu\u00ae AuraGain\u2122 and the LMA\u00ae supreme in infants and children","volume":"71","author":"Jagannathan N","year":"2016","unstructured":"Jagannathan N, Hajduk J, Sohn L, et al.. A randomised comparison of the Ambu\u00ae AuraGain\u2122 and the LMA\u00ae supreme in infants and children. Anaesthesia. 2016, 71:205-212. 10.1111\/anae.13330","journal-title":"Anaesthesia"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.7759\/cureus.10178","article-title":"Comparison of fiberoptic-guided tracheal intubation through intubating laryngeal mask airway (ILMA) FastrachTM and Ambu\u00ae Aura-i\u2122: a randomized clinical study","volume":"12","author":"Mishra N","year":"2020","unstructured":"Mishra N, Bharadwaj A. Comparison of fiberoptic-guided tracheal intubation through intubating laryngeal mask airway (ILMA) FastrachTM and Ambu\u00ae Aura-i\u2122: a randomized clinical study. Cureus. 2020, 12:e10178. 10.7759\/cureus.10178","journal-title":"Cureus"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.4097\/kjae.2013.65.4.306","article-title":"Intubating laryngeal mask airway as an independent ventilatory and intubation device. A comparison between supine, right lateral and left lateral","volume":"65","author":"Panwar M","year":"2013","unstructured":"Panwar M, Bharadwaj A, Chauhan G, Kalita D. Intubating laryngeal mask airway as an independent ventilatory and intubation device. A comparison between supine, right lateral and left lateral. Korean J Anesthesiol. 2013, 65:306-311. 10.4097\/kjae.2013.65.4.306","journal-title":"Korean J Anesthesiol"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.4103\/0019-5049.179448","article-title":"Comparison of success rate of intubation through Air-Q with ILMA using two different endotracheal tubes","volume":"60","author":"Malhotra SK","year":"2016","unstructured":"Malhotra SK, Bharath KV, Saini V. Comparison of success rate of intubation through Air-Q with ILMA using two different endotracheal tubes. Indian J Anaesth. 2016, 60:242-247. 10.4103\/0019-5049.179448","journal-title":"Indian J Anaesth"},{"key":"ref11","article-title":"Second generation extraglottic airway devices (Ambu, Air-Q,$ILMA): a comparative study to assess the relative success rate in first attempt and safety for blind tracheal intubation","volume":"1","author":"Bari N","year":"2017","unstructured":"Bari N, Shahla H, Varshney VK, Fatima N. Second generation extraglottic airway devices (Ambu, Air-Q,$ILMA): a comparative study to assess the relative success rate in first attempt and safety for blind tracheal intubation. Indian Soc Anaesth. 2017, 1:49-56.","journal-title":"Indian Soc Anaesth"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1177\/0310057X1804600508","article-title":"A randomised controlled trial comparing fibreoptic-guided tracheal intubation through two supraglottic devices: Ambu\u00ae AuraGain\u2122 laryngeal mask and LMA\u00ae Fastrach\u2122","volume":"46","author":"Preece G","year":"2018","unstructured":"Preece G, Ng I, Lee K, et al.. A randomised controlled trial comparing fibreoptic-guided tracheal intubation through two supraglottic devices: Ambu\u00ae AuraGain\u2122 laryngeal mask and LMA\u00ae Fastrach\u2122. Anaesth Intensive Care. 2018, 46:474-479. 10.1177\/0310057X1804600508","journal-title":"Anaesth Intensive Care"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1097\/00000542-199811000-00014","article-title":"A prospective evaluation of clinical tests for placement of laryngeal mask airways","volume":"89","author":"Joshi S","year":"1998","unstructured":"Joshi S, Sciacca RR, Solanki DR, Young WL, Mathru MM. A prospective evaluation of clinical tests for placement of laryngeal mask airways. Anesthesiology. 1998, 89:1141-1146. 10.1097\/00000542-199811000-00014","journal-title":"Anesthesiology"}],"container-title":["Cureus"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cureus.com\/articles\/241569-clinical-assessment-of-the-ambu-aura-i-as-an-independent-ventilatory-device-and-conduit-for-fiberoptic-guided-endotracheal-intubation-in-adults","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,4,20]],"date-time":"2024-04-20T09:37:14Z","timestamp":1713605834000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cureus.com\/articles\/241569-clinical-assessment-of-the-ambu-aura-i-as-an-independent-ventilatory-device-and-conduit-for-fiberoptic-guided-endotracheal-intubation-in-adults"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,4,20]]},"references-count":13,"URL":"https:\/\/doi.org\/10.7759\/cureus.58629","relation":{},"ISSN":["2168-8184"],"issn-type":[{"value":"2168-8184","type":"print"}],"subject":[],"published":{"date-parts":[[2024,4,20]]}}}