{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,30]],"date-time":"2025-10-30T02:09:13Z","timestamp":1761790153626},"reference-count":33,"publisher":"Springer Science and Business Media LLC","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2024,4,28]]},"DOI":"10.7759\/cureus.59215","type":"journal-article","created":{"date-parts":[[2024,4,28]],"date-time":"2024-04-28T15:58:51Z","timestamp":1714319931000},"source":"Crossref","is-referenced-by-count":4,"title":["Assessing the Efficacy of RADPAD Protection Drape in Reducing Radiation Exposure to Operators in the Cardiac Catheterization Laboratory: A Systematic Review and Meta-Analysis"],"prefix":"10.7759","author":[{"given":"Abdul Rasheed","family":"Bahar","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Resha","family":"Khanal","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mohammad","family":"Hamza","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rohit K","family":"Goru","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Aimen","family":"Shafiq","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mobeen Z","family":"Haider","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Salman Abdul","family":"Basit","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yasemin","family":"Bahar","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ahmed Muaaz","family":"Umer","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yasar","family":"Sattar","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"M. Chadi","family":"Alraies","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","reference":[{"key":"ref1","article-title":"Biological effects of ionizing radiation","volume":"159","author":"Havr\u00e1nkov\u00e1 R","year":"2020","unstructured":"Havr\u00e1nkov\u00e1 R. Biological effects of ionizing radiation. Cas Lek Cesk. 2020, 159:258-60.","journal-title":"Cas Lek Cesk"},{"key":"ref2","article-title":"The 2007 recommendations of the International Commission on Radiological Protection. ICRP publication 103","volume":"37","author":"International Commission on Radiological Protection","year":"2007","unstructured":"International Commission on Radiological Protection. The 2007 recommendations of the International Commission on Radiological Protection. ICRP publication 103. Ann ICRP. 2007, 37:1-332.","journal-title":"Ann ICRP"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1259\/bjr\/26829723","article-title":"Occupational radiation doses in interventional cardiology: a 15-year follow-up","volume":"79","author":"Va\u00f1o E","year":"2006","unstructured":"Va\u00f1o E, Gonzalez L, Fernandez JM, Alfonso F, Macaya C. Occupational radiation doses in interventional cardiology: a 15-year follow-up. Br J Radiol. 2006, 79:383-8. 10.1259\/bjr\/26829723","journal-title":"Br J Radiol"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1016\/j.ahj.2008.08.009","article-title":"Cancer risk from professional exposure in staff working in cardiac catheterization laboratory: insights from the National Research Council's Biological Effects of Ionizing Radiation VII Report","volume":"157","author":"Venneri L","year":"2009","unstructured":"Venneri L, Rossi F, Botto N, et al.. Cancer risk from professional exposure in staff working in cardiac catheterization laboratory: insights from the National Research Council's Biological Effects of Ionizing Radiation VII Report. Am Heart J. 2009, 157:118-24. 10.1016\/j.ahj.2008.08.009","journal-title":"Am Heart J"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCINTERVENTIONS.115.003273","article-title":"Occupational health risks in cardiac catheterization laboratory workers","volume":"9","author":"Andreassi MG","year":"2016","unstructured":"Andreassi MG, Piccaluga E, Guagliumi G, Del Greco M, Gaita F, Picano E. Occupational health risks in cardiac catheterization laboratory workers. Circ Cardiovasc Interv. 2016, 9:e003273. 10.1161\/CIRCINTERVENTIONS.115.003273","journal-title":"Circ Cardiovasc Interv"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.2502082558","article-title":"Occupational health hazards in the interventional laboratory: time for a safer environment","volume":"250","author":"Klein LW","year":"2009","unstructured":"Klein LW, Miller DL, Balter S, et al.. Occupational health hazards in the interventional laboratory: time for a safer environment. Radiology. 2009, 250:538-44. 10.1148\/radiol.2502082558","journal-title":"Radiology"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pmed.1000097","article-title":"Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement","volume":"6","author":"Moher D","year":"2009","unstructured":"Moher D, Liberati A, Tetzlaff J, Altman DG. Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. PLoS Med. 2009, 6:e1000097. 10.1371\/journal.pmed.1000097","journal-title":"PLoS Med"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.j4008","article-title":"AMSTAR 2: a critical appraisal tool for systematic reviews that include randomised or non-randomised studies of healthcare interventions, or both","volume":"358","author":"Shea BJ","year":"2017","unstructured":"Shea BJ, Reeves BC, Wells G, et al.. AMSTAR 2: a critical appraisal tool for systematic reviews that include randomised or non-randomised studies of healthcare interventions, or both. BMJ. 2017, 358:j4008. 10.1136\/bmj.j4008","journal-title":"BMJ"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.1111\/j.1467-985X.2008.00552.x","article-title":"A re-evaluation of random-effects meta-analysis","volume":"172","author":"Higgins JP","year":"2009","unstructured":"Higgins JP, Thompson SG, Spiegelhalter DJ. A re-evaluation of random-effects meta-analysis. J R Stat Soc Ser A Stat Soc. 2009, 172:137-59. 10.1111\/j.1467-985X.2008.00552.x","journal-title":"J R Stat Soc Ser A Stat Soc"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCINTERVENTIONS.117.006058","article-title":"Efficacy of the RADPAD protection drape in reducing operators\u2019 radiation exposure in the catheterization laboratory: a sham-controlled randomized trial","volume":"10","author":"Vlastra W","year":"2017","unstructured":"Vlastra W, Delewi R, Sjauw KD, et al.. Efficacy of the RADPAD protection drape in reducing operators\u2019 radiation exposure in the catheterization laboratory: a sham-controlled randomized trial. Circ Cardiovasc Interv. 2017, 10:e006058. 10.1161\/CIRCINTERVENTIONS.117.006058","journal-title":"Circ Cardiovasc Interv"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.22947","article-title":"Reduction of scatter radiation during transradial percutaneous coronary angiography: a randomized trial using a lead-free radiation shield","volume":"79","author":"Politi L","year":"2012","unstructured":"Politi L, Biondi-Zoccai G, Nocetti L, et al.. Reduction of scatter radiation during transradial percutaneous coronary angiography: a randomized trial using a lead-free radiation shield. Catheter Cardiovasc Interv. 2012, 79:97-102. 10.1002\/ccd.22947","journal-title":"Catheter Cardiovasc Interv"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1016\/j.amjcard.2011.06.061","article-title":"Efficacy of the RADPAD protective drape during real world complex percutaneous coronary intervention procedures","volume":"108","author":"Murphy JC","year":"2011","unstructured":"Murphy JC, Darragh K, Walsh SJ, Hanratty CG. Efficacy of the RADPAD protective drape during real world complex percutaneous coronary intervention procedures. Am J Cardiol. 2011, 108:1408-10. 10.1016\/j.amjcard.2011.06.061","journal-title":"Am J Cardiol"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1016\/j.ihj.2022.04.001","article-title":"Minimizing scattered radiation dose in cardiac catheterization laboratory during interventional procedures using lead free drape - MILD study","volume":"74","author":"Bhat KG","year":"2022","unstructured":"Bhat KG, Guleria VS, Singla M, et al.. Minimizing scattered radiation dose in cardiac catheterization laboratory during interventional procedures using lead free drape - MILD study. Indian Heart J. 2022, 74:201-5. 10.1016\/j.ihj.2022.04.001","journal-title":"Indian Heart J"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.1016\/j.ihj.2018.03.008","article-title":"Efficacy of RADPAD protection drape in reducing radiation exposure in the catheterization laboratory\u2014first Indian study","volume":"70","author":"Shah P","year":"2018","unstructured":"Shah P, Khanna R, Kapoor A, Goel PK. Efficacy of RADPAD protection drape in reducing radiation exposure in the catheterization laboratory\u2014first Indian study. Indian Heart J. 2018, 70:S265-8. 10.1016\/j.ihj.2018.03.008","journal-title":"Indian Heart J"},{"key":"ref15","doi-asserted-by":"publisher","DOI":"10.1007\/s00059-017-4560-7","article-title":"Efficacy of RADPAD protective drape during coronary angiography","volume":"43","author":"Kherad B","year":"2018","unstructured":"Kherad B, Jerichow T, Blaschke F, Noutsias M, Pieske B, Tsch\u00f6pe C, Krackhardt F. Efficacy of RADPAD protective drape during coronary angiography. Herz. 2018, 43:310-4. 10.1007\/s00059-017-4560-7","journal-title":"Herz"},{"key":"ref16","doi-asserted-by":"publisher","DOI":"10.1002\/14651858.ED000142","article-title":"Updated guidance for trusted systematic reviews: a new edition of the Cochrane Handbook for Systematic Reviews of Interventions","volume":"10","author":"Cumpston M","year":"2019","unstructured":"Cumpston M, Li T, Page MJ, Chandler J, Welch VA, Higgins JP, Thomas J. Updated guidance for trusted systematic reviews: a new edition of the Cochrane Handbook for Systematic Reviews of Interventions. Cochrane Database Syst Rev. 2019, 10:ED000142. 10.1002\/14651858.ED000142","journal-title":"Cochrane Database Syst Rev"},{"key":"ref17","unstructured":"Radiation safety in the cath lab. does it still matter?. (2020). Accessed: December 28, 2023: https:\/\/www.britishcardiovascularsociety.org\/resources\/editorials\/articles\/radiation-safety-in-the-cath-lab-does-it-s...."},{"key":"ref18","article-title":"Radiobiology for the Radiologist","author":"Hall EJ","year":"2019","unstructured":"Hall EJ, Giaccia AJ. Radiobiology for the Radiologist. Wolters Kluwer, Philadelphia, PA; 2019."},{"key":"ref19","doi-asserted-by":"publisher","DOI":"10.1016\/j.icrp.2012.06.018","article-title":"Radiation cataract","volume":"41","author":"Kleiman NJ","year":"2012","unstructured":"Kleiman NJ. Radiation cataract. Ann ICRP. 2012, 41:80-97. 10.1016\/j.icrp.2012.06.018","journal-title":"Ann ICRP"},{"key":"ref20","doi-asserted-by":"publisher","DOI":"10.1155\/2011\/609537","article-title":"The risk of radiation exposure to the eyes of the interventional pain physician","volume":"2011","author":"Fish DE","year":"2011","unstructured":"Fish DE, Kim A, Ornelas C, Song S, Pangarkar S. The risk of radiation exposure to the eyes of the interventional pain physician. Radiol Res Pract. 2011, 2011:609537. 10.1155\/2011\/609537","journal-title":"Radiol Res Pract"},{"key":"ref21","doi-asserted-by":"publisher","DOI":"10.1667\/RR1884.1","article-title":"Epidemiological studies of cataract risk at low to moderate radiation doses: (not) seeing is believing","volume":"174","author":"Shore RE","year":"2010","unstructured":"Shore RE, Neriishi K, Nakashima E. Epidemiological studies of cataract risk at low to moderate radiation doses: (not) seeing is believing. Radiat Res. 2010, 174:889-94. 10.1667\/RR1884.1","journal-title":"Radiat Res"},{"key":"ref22","doi-asserted-by":"publisher","DOI":"10.17226\/9526","article-title":"Health Risks from Exposure to Low Levels of Ionizing Radiation: BEIR VII, Phase I, Letter Report","author":"National Research Council","year":"1998","unstructured":"National Research Council. Health Risks from Exposure to Low Levels of Ionizing Radiation: BEIR VII, Phase I, Letter Report. The National Academies Press, Washington, DC; 1998. 10.17226\/9526"},{"key":"ref23","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.21004","article-title":"Occupational hazards for interventional cardiologists","volume":"68","author":"Dehmer GJ","year":"2006","unstructured":"Dehmer GJ. Occupational hazards for interventional cardiologists. Catheter Cardiovasc Interv. 2006, 68:974-6. 10.1002\/ccd.21004","journal-title":"Catheter Cardiovasc Interv"},{"key":"ref24","doi-asserted-by":"publisher","DOI":"10.2214\/ajr.178.1.1780153","article-title":"Using a sterile disposable protective surgical drape for reduction of radiation exposure to interventionalists","volume":"178","author":"King JN","year":"2002","unstructured":"King JN, Champlin AM, Kelsey CA, Tripp DA. Using a sterile disposable protective surgical drape for reduction of radiation exposure to interventionalists. AJR Am J Roentgenol. 2002, 178:153-7. 10.2214\/ajr.178.1.1780153","journal-title":"AJR Am J Roentgenol"},{"key":"ref25","doi-asserted-by":"publisher","DOI":"10.5402\/2012\/769167","article-title":"Radiation dose reduction during radial cardiac catheterization: evaluation of a dedicated radial angiography absorption shielding drape","volume":"2012","author":"Ertel A","year":"2012","unstructured":"Ertel A, Nadelson J, Shroff AR, Sweis R, Ferrera D, Vidovich MI. Radiation dose reduction during radial cardiac catheterization: evaluation of a dedicated radial angiography absorption shielding drape. ISRN Cardiol. 2012, 2012:769167. 10.5402\/2012\/769167","journal-title":"ISRN Cardiol"},{"key":"ref26","doi-asserted-by":"publisher","DOI":"10.1097\/01.RVI.0000228372.62738.36","article-title":"Heavy metal pad shielding during fluoroscopic interventions","volume":"17","author":"Dromi S","year":"2006","unstructured":"Dromi S, Wood BJ, Oberoi J, Neeman Z. Heavy metal pad shielding during fluoroscopic interventions. J Vasc Interv Radiol. 2006, 17:1201-6. 10.1097\/01.RVI.0000228372.62738.36","journal-title":"J Vasc Interv Radiol"},{"key":"ref27","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejvs.2013.12.008","article-title":"Editor's choice--use of disposable radiation-absorbing surgical drapes results in significant dose reduction during EVAR procedures","volume":"47","author":"Kloeze C","year":"2014","unstructured":"Kloeze C, Klompenhouwer EG, Brands PJ, van Sambeek MR, Cuypers PW, Teijink JA. Editor's choice--use of disposable radiation-absorbing surgical drapes results in significant dose reduction during EVAR procedures. Eur J Vasc Endovasc Surg. 2014, 47:268-72. 10.1016\/j.ejvs.2013.12.008","journal-title":"Eur J Vasc Endovasc Surg"},{"key":"ref28","doi-asserted-by":"publisher","DOI":"10.1016\/0735-1097(94)90171-6","article-title":"Modifying fluoroscopic views reduces operator radiation exposure during coronary angioplasty","volume":"24","author":"Pitney MR","year":"1994","unstructured":"Pitney MR, Allan RM, Giles RW, McLean D, McCredie M, Randell T, Walsh WF. Modifying fluoroscopic views reduces operator radiation exposure during coronary angioplasty. J Am Coll Cardiol. 1994, 24:1660-3. 10.1016\/0735-1097(94)90171-6","journal-title":"J Am Coll Cardiol"},{"key":"ref29","doi-asserted-by":"publisher","DOI":"10.1093\/europace\/euq356","article-title":"Reducing operator radiation exposure during cardiac resynchronization therapy","volume":"12","author":"Brambilla M","year":"2010","unstructured":"Brambilla M, Occhetta E, Ronconi M, Plebani L, Carriero A, Marino P. Reducing operator radiation exposure during cardiac resynchronization therapy. Europace. 2010, 12:1769-73. 10.1093\/europace\/euq356","journal-title":"Europace"},{"key":"ref30","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcin.2014.12.233","article-title":"Subclinical carotid atherosclerosis and early\u00a0vascular aging from long-term low-dose\u00a0ionizing radiation exposure: a genetic, telomere, and vascular ultrasound study in cardiac\u00a0catheterization laboratory staff","volume":"8","author":"Andreassi MG","year":"2015","unstructured":"Andreassi MG, Piccaluga E, Gargani L, et al.. Subclinical carotid atherosclerosis and early\u00a0vascular aging from long-term low-dose\u00a0ionizing radiation exposure: a genetic, telomere, and vascular ultrasound study in cardiac\u00a0catheterization laboratory staff. JACC Cardiovasc Interv. 2015, 8:616-27. 10.1016\/j.jcin.2014.12.233","journal-title":"JACC Cardiovasc Interv"},{"key":"ref31","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacep.2020.08.007","article-title":"Efficiency of the RADPAD surgical cap in reducing brain exposure during pacemaker and defibrillator implantation","volume":"7","author":"Lemesre C","year":"2021","unstructured":"Lemesre C, Graf D, Bisch L, et al.. Efficiency of the RADPAD surgical cap in reducing brain exposure during pacemaker and defibrillator implantation. JACC Clin Electrophysiol. 2021, 7:161-70. 10.1016\/j.jacep.2020.08.007","journal-title":"JACC Clin Electrophysiol"},{"key":"ref32","doi-asserted-by":"publisher","DOI":"10.1016\/j.avsg.2022.01.030","article-title":"Reduction of occupational radiation exposure during endovascular treatment of peripheral artery disease using radiation absorbing drapes","volume":"84","author":"Jansen MM","year":"2022","unstructured":"Jansen MM, Koster A, van Herwaarden JA, Hazenberg CE. Reduction of occupational radiation exposure during endovascular treatment of peripheral artery disease using radiation absorbing drapes. Ann Vasc Surg. 2022, 84:336-43. 10.1016\/j.avsg.2022.01.030","journal-title":"Ann Vasc Surg"},{"key":"ref33","doi-asserted-by":"publisher","DOI":"10.1093\/rpd\/ncaa169","article-title":"The efficacy of RADPAD as a radiation protection tool in CT fluoroscopy guided lung biopsies","volume":"191","author":"Lawson M","year":"2020","unstructured":"Lawson M, Kuganesan A, Parry G, Badawy MK. The efficacy of RADPAD as a radiation protection tool in CT fluoroscopy guided lung biopsies. Radiat Prot Dosimetry. 2020, 191:328-34. 10.1093\/rpd\/ncaa169","journal-title":"Radiat Prot Dosimetry"}],"container-title":["Cureus"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cureus.com\/articles\/232108-assessing-the-efficacy-of-radpad-protection-drape-in-reducing-radiation-exposure-to-operators-in-the-cardiac-catheterization-laboratory-a-systematic-review-and-meta-analysis","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,4,28]],"date-time":"2024-04-28T15:58:56Z","timestamp":1714319936000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cureus.com\/articles\/232108-assessing-the-efficacy-of-radpad-protection-drape-in-reducing-radiation-exposure-to-operators-in-the-cardiac-catheterization-laboratory-a-systematic-review-and-meta-analysis"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,4,28]]},"references-count":33,"URL":"https:\/\/doi.org\/10.7759\/cureus.59215","relation":{},"ISSN":["2168-8184"],"issn-type":[{"value":"2168-8184","type":"print"}],"subject":[],"published":{"date-parts":[[2024,4,28]]}}}