{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,2]],"date-time":"2026-06-02T10:44:20Z","timestamp":1780397060438,"version":"3.54.1"},"reference-count":30,"publisher":"Springer Science and Business Media LLC","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2024,5,19]]},"DOI":"10.7759\/cureus.60595","type":"journal-article","created":{"date-parts":[[2024,5,19]],"date-time":"2024-05-19T12:49:15Z","timestamp":1716122955000},"source":"Crossref","is-referenced-by-count":1,"title":["Outcomes of Autologous and Synthetic Bone Grafts in Locking Plate Fixation of Comminuted Distal Radius Fractures"],"prefix":"10.7759","author":[{"given":"Dhivakaran","family":"Gengatharan","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Walter","family":"Wong","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dawn S","family":"Chia","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1016\/j.hcl.2012.02.001","article-title":"The epidemiology of distal radius fractures","volume":"28","author":"Nellans KW","year":"2012","unstructured":"Nellans KW, Kowalski E, Chung KC. The epidemiology of distal radius fractures. Hand Clin. 2012, 28:113-25. 10.1016\/j.hcl.2012.02.001","journal-title":"Hand Clin"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.E.01298","article-title":"Treatment of unstable distal radial fractures with the volar locking plating system","volume":"88","author":"Chung KC","year":"2006","unstructured":"Chung KC, Watt AJ, Kotsis SV, Margaliot Z, Haase SC, Kim HM. Treatment of unstable distal radial fractures with the volar locking plating system. J Bone Joint Surg Am. 2006, 88:2687-94. 10.2106\/JBJS.E.01298","journal-title":"J Bone Joint Surg Am"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1016\/j.jhsa.2018.05.007","article-title":"Cost of surgical treatment for distal radius fractures and the implications of episode-based bundled payments","volume":"43","author":"Huetteman HE","year":"2018","unstructured":"Huetteman HE, Zhong L, Chung KC. Cost of surgical treatment for distal radius fractures and the implications of episode-based bundled payments. J Hand Surg Am. 2018, 43:720-30. 10.1016\/j.jhsa.2018.05.007","journal-title":"J Hand Surg Am"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.F.00703","article-title":"The evolution of locked plates","volume":"88 Suppl 4","author":"Kubiak EN","year":"2006","unstructured":"Kubiak EN, Fulkerson E, Strauss E, Egol KA. The evolution of locked plates. J Bone Joint Surg Am. 2006, 88 Suppl 4:189-200. 10.2106\/JBJS.F.00703","journal-title":"J Bone Joint Surg Am"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1016\/j.clinbiomech.2007.08.004","article-title":"A review of locking compression plate biomechanics and their advantages as internal fixators in fracture healing","volume":"22","author":"Miller DL","year":"2007","unstructured":"Miller DL, Goswami T. A review of locking compression plate biomechanics and their advantages as internal fixators in fracture healing. Clin Biomech (Bristol, Avon). 2007, 22:1049-62. 10.1016\/j.clinbiomech.2007.08.004","journal-title":"Clin Biomech (Bristol, Avon)"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1016\/s0020-1383(00)80027-3","article-title":"Effect of plate position relative to bending direction on the rigidity of a plate osteosynthesis. A theoretical analysis","volume":"31","author":"Gautier E","year":"2000","unstructured":"Gautier E, Perren SM, Cordey J. Effect of plate position relative to bending direction on the rigidity of a plate osteosynthesis. A theoretical analysis. Injury. 2000, 31:14-20. 10.1016\/s0020-1383(00)80027-3","journal-title":"Injury"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2003.09.021","article-title":"Biomechanical testing of the LCP--how can stability in locked internal fixators be controlled?","volume":"34 Suppl 2","author":"Stoffel K","year":"2003","unstructured":"Stoffel K, Dieter U, Stachowiak G, G\u00e4chter A, Kuster MS. Biomechanical testing of the LCP--how can stability in locked internal fixators be controlled?. Injury. 2003, 34 Suppl 2:B11-9. 10.1016\/j.injury.2003.09.021","journal-title":"Injury"},{"key":"ref8","doi-asserted-by":"crossref","DOI":"10.55095\/achot2013\/030","article-title":"Locking plates: a current concepts review of technique and indications for use","volume":"80","author":"Hunt S","year":"2013","unstructured":"Hunt S, Buckley R. Locking plates: a current concepts review of technique and indications for use. Acta Chir Orthop Traumatol Cech. 2013, 80:185-91.","journal-title":"Acta Chir Orthop Traumatol Cech"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.938ebo","article-title":"American Academy of Orthopaedic Surgeons clinical practice guideline on: the treatment of distal radius fractures","volume":"93","author":"Lichtman DM","year":"2011","unstructured":"Lichtman DM, Bindra RR, Boyer MI, et al.. American Academy of Orthopaedic Surgeons clinical practice guideline on: the treatment of distal radius fractures. J Bone Joint Surg Am. 2011, 93:775-8. 10.2106\/JBJS.938ebo","journal-title":"J Bone Joint Surg Am"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.71B5.2584256","article-title":"Ligamentotaxis and bone grafting for comminuted fractures of the distal radius","volume":"71","author":"Leung KS","year":"1989","unstructured":"Leung KS, Shen WY, Leung PC, Kinninmonth AW, Chang JC, Chan GP. Ligamentotaxis and bone grafting for comminuted fractures of the distal radius. J Bone Joint Surg Br. 1989, 71:838-42. 10.1302\/0301-620X.71B5.2584256","journal-title":"J Bone Joint Surg Br"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1016\/0363-5023(91)90002-s","article-title":"External fixation of distal radial fractures: results and complications","volume":"16","author":"Sanders R","year":"1991","unstructured":"Sanders R, Keppel F, Waldrop J. External fixation of distal radial fractures: results and complications. J Hand Surg Am. 1991, 16:385-91. 10.1016\/0363-5023(91)90002-s","journal-title":"J Hand Surg Am"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1097\/00005373-199806000-00007","article-title":"Long-term results of the external fixation of distal radius fractures","volume":"44","author":"Rikli DA","year":"1998","unstructured":"Rikli DA, K\u00fcpfer K, Bodoky A. Long-term results of the external fixation of distal radius fractures. J Trauma. 1998, 44:970-6. 10.1097\/00005373-199806000-00007","journal-title":"J Trauma"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1007\/BF00381396","article-title":"Osteoinduction. Part I: test model and comparative long term observation of allogenic and xenogenic matrix implants","volume":"99","author":"Thielemann FW","year":"1982","unstructured":"Thielemann FW, Spaeth G, Veihelmann D, Schmidt K. Osteoinduction. Part I: test model and comparative long term observation of allogenic and xenogenic matrix implants. Arch Orthop Trauma Surg (1978). 1982, 99:217-22. 10.1007\/BF00381396","journal-title":"Arch Orthop Trauma Surg (1978)"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-197409000-00086","article-title":"Allograft induced osteoinduction in rats. A circadian rhythm","author":"Simmons DJ","year":"1974","unstructured":"Simmons DJ, Sherman NE, Lesker PA. Allograft induced osteoinduction in rats. A circadian rhythm. Clin Orthop Relat Res. 1974, 252-61. 10.1097\/00003086-197409000-00086","journal-title":"Clin Orthop Relat Res"},{"key":"ref15","doi-asserted-by":"crossref","DOI":"10.1097\/00003086-197209000-00014","article-title":"Osteoinduction and osteogenesis in implants of allogeneic bone matrix: influence of somatotropin, thyrotropin, and cortisone","volume":"87","author":"Koskinen E","year":"1972","unstructured":"Koskinen E, Ryppy S, Lindholm T. Osteoinduction and osteogenesis in implants of allogeneic bone matrix: influence of somatotropin, thyrotropin, and cortisone. Clin Orthop Relat Res. 1972, 87:116 -131.","journal-title":"Clin Orthop Relat Res"},{"key":"ref16","doi-asserted-by":"publisher","DOI":"10.1002\/jor.1100150518","article-title":"Improved osteoinduction of cortical bone allografts: a study of the effects of laser perforation and partial demineralization","volume":"15","author":"Lewandrowski KU","year":"1997","unstructured":"Lewandrowski KU, Tomford WW, Schomacker KT, Deutsch TF, Mankin HJ. Improved osteoinduction of cortical bone allografts: a study of the effects of laser perforation and partial demineralization. J Orthop Res. 1997, 15:748-56. 10.1002\/jor.1100150518","journal-title":"J Orthop Res"},{"key":"ref17","doi-asserted-by":"publisher","DOI":"10.1016\/j.hcl.2012.02.004","article-title":"The use of bone grafts and substitutes in the treatment of distal radius fractures","volume":"28","author":"Ozer K","year":"2012","unstructured":"Ozer K, Chung KC. The use of bone grafts and substitutes in the treatment of distal radius fractures. Hand Clin. 2012, 28:217-23. 10.1016\/j.hcl.2012.02.004","journal-title":"Hand Clin"},{"key":"ref18","doi-asserted-by":"crossref","DOI":"10.2106\/00004623-198668050-00003","article-title":"Intra-articular fractures of the distal end of the radius in young adults","volume":"68","author":"Knirk J","year":"1986","unstructured":"Knirk J, Jupiter J. Intra-articular fractures of the distal end of the radius in young adults. J Bone Joint Surg Am. 1986, 68:647-59.","journal-title":"J Bone Joint Surg Am"},{"key":"ref19","doi-asserted-by":"publisher","DOI":"10.1016\/s0363-5023(85)80246-x","article-title":"Functional wrist motion: a biomechanical study","volume":"10","author":"Palmer AK","year":"1985","unstructured":"Palmer AK, Werner FW, Murphy D, Glisson R. Functional wrist motion: a biomechanical study. J Hand Surg Am. 1985, 10:39-46. 10.1016\/s0363-5023(85)80246-x","journal-title":"J Hand Surg Am"},{"key":"ref20","doi-asserted-by":"publisher","DOI":"10.1016\/0363-5023(91)90006-w","article-title":"Functional ranges of motion of the wrist joint","volume":"16","author":"Ryu JY","year":"1991","unstructured":"Ryu JY, Cooney WP, Askew LJ, An KN, Chao EY. Functional ranges of motion of the wrist joint. J Hand Surg Am. 1991, 16:409-19. 10.1016\/0363-5023(91)90006-w","journal-title":"J Hand Surg Am"},{"key":"ref21","doi-asserted-by":"publisher","DOI":"10.1016\/S0363-5023(05)80153-4","article-title":"Design and biomechanics of a plate for the distal radius","volume":"20","author":"Gesensway D","year":"1995","unstructured":"Gesensway D, Putnam MD, Mente PL, Lewis JL. Design and biomechanics of a plate for the distal radius. J Hand Surg Am. 1995, 20:1021-7. 10.1016\/S0363-5023(05)80153-4","journal-title":"J Hand Surg Am"},{"key":"ref22","doi-asserted-by":"publisher","DOI":"10.1002\/14651858.CD006836.pub2","article-title":"Bone grafts and bone substitutes for treating distal radial fractures in adults","volume":"2008","author":"Handoll HH","year":"2008","unstructured":"Handoll HH, Watts AC. Bone grafts and bone substitutes for treating distal radial fractures in adults. Cochrane Database Syst Rev. 2008, 2008:CD006836. 10.1002\/14651858.CD006836.pub2","journal-title":"Cochrane Database Syst Rev"},{"key":"ref23","doi-asserted-by":"publisher","DOI":"10.1142\/S2424835523500091","article-title":"Retrospective comparative study of clinical outcomes and cost-effectiveness with bone substitutes on volar locking plate fixation of unstable distal radial fractures in the elderly","volume":"28","author":"Mori Y","year":"2023","unstructured":"Mori Y, Takegami Y, Tokutake K, Oka Y, Imagama S. Retrospective comparative study of clinical outcomes and cost-effectiveness with bone substitutes on volar locking plate fixation of unstable distal radial fractures in the elderly. J Hand Surg Asian Pac Vol. 2023, 28:61-8. 10.1142\/S2424835523500091","journal-title":"J Hand Surg Asian Pac Vol"},{"key":"ref24","doi-asserted-by":"publisher","DOI":"10.1186\/s12891-020-03203-7","article-title":"Evaluating the necessity of bone augmentation for distal radius fracture fixed with a volar locking plate: a retrospective study","volume":"21","author":"Chang FS","year":"2020","unstructured":"Chang FS, Chen CH, Lee CH, Lee KT, Cho YC. Evaluating the necessity of bone augmentation for distal radius fracture fixed with a volar locking plate: a retrospective study. BMC Musculoskelet Disord. 2020, 21:180. 10.1186\/s12891-020-03203-7","journal-title":"BMC Musculoskelet Disord"},{"key":"ref25","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.G.01498","article-title":"Operative management of distal radial fractures with 2.4-millimeter locking plates. A multicenter prospective case series","volume":"91","author":"Jupiter JB","year":"2009","unstructured":"Jupiter JB, Marent-Huber M. Operative management of distal radial fractures with 2.4-millimeter locking plates. A multicenter prospective case series. J Bone Joint Surg Am. 2009, 91:55-65. 10.2106\/JBJS.G.01498","journal-title":"J Bone Joint Surg Am"},{"key":"ref26","doi-asserted-by":"publisher","DOI":"10.1016\/j.jhsa.2010.10.006","article-title":"The role of bone grafting in distal radius fractures","volume":"35","author":"Tosti R","year":"2010","unstructured":"Tosti R, Ilyas AM. The role of bone grafting in distal radius fractures. J Hand Surg Am. 2010, 35:2082-4. 10.1016\/j.jhsa.2010.10.006","journal-title":"J Hand Surg Am"},{"key":"ref27","doi-asserted-by":"publisher","DOI":"10.1142\/S0218810411005023","article-title":"Use of the volar fixed angle plate for comminuted distal radius fractures and augmentation with a hydroxyapatite bone graft substitute","volume":"16","author":"Goto A","year":"2011","unstructured":"Goto A, Murase T, Oka K, Yoshikawa H. Use of the volar fixed angle plate for comminuted distal radius fractures and augmentation with a hydroxyapatite bone graft substitute. Hand Surg. 2011, 16:29-37. 10.1142\/S0218810411005023","journal-title":"Hand Surg"},{"key":"ref28","doi-asserted-by":"publisher","DOI":"10.23750\/abm.v92i3.11265","article-title":"Clinical, functional and radiological outcomes of the use of fixed angle volar locking plates in corrective distal radius osteotomy for fracture malunion","volume":"92","author":"Valerio Pace","year":"2021","unstructured":"Valerio Pace, Pasquale Sessa, Matteo Guzzini, et al.. Clinical, functional and radiological outcomes of the use of fixed angle volar locking plates in corrective distal radius osteotomy for fracture malunion. Acta Biomed. 2021, 92:e2021180. 10.23750\/abm.v92i3.11265","journal-title":"Acta Biomed"},{"key":"ref29","doi-asserted-by":"publisher","DOI":"10.1186\/1749-799X-6-24","article-title":"The use of beta-tricalcium phosphate bone graft substitute in dorsally plated, comminuted distal radius fractures","volume":"6","author":"Jakubietz MG","year":"2011","unstructured":"Jakubietz MG, Gruenert JG, Jakubietz RG. The use of beta-tricalcium phosphate bone graft substitute in dorsally plated, comminuted distal radius fractures. J Orthop Surg Res. 2011, 6:24. 10.1186\/1749-799X-6-24","journal-title":"J Orthop Surg Res"},{"key":"ref30","doi-asserted-by":"publisher","DOI":"10.1097\/01.ta.0000195977.18035.40","article-title":"Cancellous allograft versus autologous bone grafting for repair of comminuted distal radius fractures: a prospective, randomized trial","volume":"60","author":"Rajan GP","year":"2006","unstructured":"Rajan GP, Fornaro J, Trentz O, Zellweger R. Cancellous allograft versus autologous bone grafting for repair of comminuted distal radius fractures: a prospective, randomized trial. J Trauma. 2006, 60:1322-9. 10.1097\/01.ta.0000195977.18035.40","journal-title":"J Trauma"}],"container-title":["Cureus"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cureus.com\/articles\/244935-outcomes-of-autologous-and-synthetic-bone-grafts-in-locking-plate-fixation-of-comminuted-distal-radius-fractures","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,5,19]],"date-time":"2024-05-19T12:49:23Z","timestamp":1716122963000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cureus.com\/articles\/244935-outcomes-of-autologous-and-synthetic-bone-grafts-in-locking-plate-fixation-of-comminuted-distal-radius-fractures"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,5,19]]},"references-count":30,"URL":"https:\/\/doi.org\/10.7759\/cureus.60595","relation":{},"ISSN":["2168-8184"],"issn-type":[{"value":"2168-8184","type":"print"}],"subject":[],"published":{"date-parts":[[2024,5,19]]}}}