{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,15]],"date-time":"2025-12-15T19:53:16Z","timestamp":1765828396124},"reference-count":11,"publisher":"Springer Science and Business Media LLC","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2024,5,26]]},"DOI":"10.7759\/cureus.61114","type":"journal-article","created":{"date-parts":[[2024,5,26]],"date-time":"2024-05-26T15:16:16Z","timestamp":1716736576000},"source":"Crossref","is-referenced-by-count":2,"title":["Resolution of Confusion Over Compartment Syndrome After Tibial Osteotomy With Continuous Pressure Measurements"],"prefix":"10.7759","author":[{"given":"Abdullah","family":"Haidar","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Thierry","family":"Pauyo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Edward","family":"Harvey","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Justin","family":"Drager","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1097\/BOT.0000000000000317","article-title":"Interobserver variability in the measurement of lower leg compartment pressures","volume":"29","author":"Large TM","year":"2015","unstructured":"Large TM, Agel J, Holtzman DJ, Benirschke SK, Krieg JC. Interobserver variability in the measurement of lower leg compartment pressures. J Orthop Trauma. 2015, 29:316-21. 10.1097\/BOT.0000000000000317","journal-title":"J Orthop Trauma"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.RVW.17.00016","article-title":"The diagnosis of acute compartment syndrome: a critical analysis review","volume":"5","author":"Duckworth AD","year":"2017","unstructured":"Duckworth AD, McQueen MM. The diagnosis of acute compartment syndrome: a critical analysis review. JBJS Rev. 2017, 5:e1. 10.2106\/JBJS.RVW.17.00016","journal-title":"JBJS Rev"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1097\/BOT.0000000000002610","article-title":"Diagnosis accuracy for compartment syndrome: a systematic review and meta-analysis","volume":"37","author":"Lorange JP","year":"2023","unstructured":"Lorange JP, Laverdi\u00e8re C, Corban J, Montreuil J, Harvey EJ. Diagnosis accuracy for compartment syndrome: a systematic review and meta-analysis. J Orthop Trauma. 2023, 37:e319-25. 10.1097\/BOT.0000000000002610","journal-title":"J Orthop Trauma"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.5435\/JAAOSGlobal-D-23-00075","article-title":"Avoiding compartment syndrome, vascular injury, and neurologic deficit in tibial osteotomy: an observational study of 108 limbs","volume":"7","author":"Hoellwarth JS","year":"2023","unstructured":"Hoellwarth JS, Geffner A, Fragomen AT, Reif TJ, Rozbruch SR. Avoiding compartment syndrome, vascular injury, and neurologic deficit in tibial osteotomy: an observational study of 108 limbs. J Am Acad Orthop Surg Glob Res Rev. 2023, 7:e23.00075. 10.5435\/JAAOSGlobal-D-23-00075","journal-title":"J Am Acad Orthop Surg Glob Res Rev"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.ST.M.00023","article-title":"Continuous intracompartmental pressure monitoring for acute compartment syndrome","volume":"3","author":"Duckworth AD","year":"2014","unstructured":"Duckworth AD, McQueen MM. Continuous intracompartmental pressure monitoring for acute compartment syndrome. JBJS Essent Surg Tech. 2014, 3:e13. 10.2106\/JBJS.ST.M.00023","journal-title":"JBJS Essent Surg Tech"},{"key":"ref6","article-title":"Clinical trial of a new device for real time muscle pressure measurements in patients with an upper or lower extremity fracture at risk for compartment syndrome","volume":"104","author":"Leighton R","year":"2022","unstructured":"Leighton R, Schneider P, Trask K, Balhareth M. Clinical trial of a new device for real time muscle pressure measurements in patients with an upper or lower extremity fracture at risk for compartment syndrome. Ortho Proc. 2022, 104:108.","journal-title":"Ortho Proc"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1093\/milmed\/usz305","article-title":"Comparison of three devices to measure pressure for acute compartment syndrome","volume":"185","author":"Merle G","year":"2020","unstructured":"Merle G, Comeau-Gauthier M, Tayari V, et al.. Comparison of three devices to measure pressure for acute compartment syndrome. Mil Med. 2020, 185:77-81. 10.1093\/milmed\/usz305","journal-title":"Mil Med"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2022.02.041","article-title":"Big data insights into predictors of acute compartment syndrome","volume":"53","author":"Bouklouch Y","year":"2022","unstructured":"Bouklouch Y, Schmidt AH, Obremskey WT, Bernstein M, Gamburg N, Harvey EJ. Big data insights into predictors of acute compartment syndrome. Injury. 2022, 53:2557-61. 10.1016\/j.injury.2022.02.041","journal-title":"Injury"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.1007\/s00542-016-3015-z","article-title":"Capacitive MEMS absolute pressure sensor using a modified commercial microfabrication process","volume":"23","author":"Merdassi A","year":"2017","unstructured":"Merdassi A, Allan C, Harvey E, Chodavarapu VP. Capacitive MEMS absolute pressure sensor using a modified commercial microfabrication process. Microsys Technol. 2017, 23:3215-25. 10.1007\/s00542-016-3015-z","journal-title":"Microsys Technol"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.1097\/BOT.0000000000002663","article-title":"Postfasciotomy classification system for acute compartment syndrome of the leg","volume":"37","author":"Bouklouch Y","year":"2023","unstructured":"Bouklouch Y, Bernstein M, Bosse M, et al.. Postfasciotomy classification system for acute compartment syndrome of the leg. J Orthop Trauma. 2023, 37:581-5. 10.1097\/BOT.0000000000002663","journal-title":"J Orthop Trauma"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.21.00291","article-title":"Acute compartment syndrome modeling with sequential infusion shows the deep posterior compartment is not functionally discrete","volume":"104","author":"Schupbach D","year":"2022","unstructured":"Schupbach D, Honjol Y, Bouklouch Y, Merle G, Harvey EJ. Acute compartment syndrome modeling with sequential infusion shows the deep posterior compartment is not functionally discrete. J Bone Joint Surg Am. 2022, 104:813-20. 10.2106\/JBJS.21.00291","journal-title":"J Bone Joint Surg Am"}],"container-title":["Cureus"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cureus.com\/articles\/251557-resolution-of-confusion-over-compartment-syndrome-after-tibial-osteotomy-with-continuous-pressure-measurements","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,5,26]],"date-time":"2024-05-26T15:16:19Z","timestamp":1716736579000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cureus.com\/articles\/251557-resolution-of-confusion-over-compartment-syndrome-after-tibial-osteotomy-with-continuous-pressure-measurements"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,5,26]]},"references-count":11,"URL":"https:\/\/doi.org\/10.7759\/cureus.61114","relation":{},"ISSN":["2168-8184"],"issn-type":[{"value":"2168-8184","type":"print"}],"subject":[],"published":{"date-parts":[[2024,5,26]]}}}