{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,4]],"date-time":"2026-06-04T18:27:39Z","timestamp":1780597659643,"version":"3.54.1"},"reference-count":14,"publisher":"Springer Science and Business Media LLC","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2024,6,19]]},"DOI":"10.7759\/cureus.62674","type":"journal-article","created":{"date-parts":[[2024,6,19]],"date-time":"2024-06-19T10:10:13Z","timestamp":1718791813000},"source":"Crossref","is-referenced-by-count":4,"title":["A Comparative Evaluation of Stress Distribution Around Different Widths of Implant and Bony Interface in Function During Axial and Non-axial Loading: A Finite Element Analysis"],"prefix":"10.7759","author":[{"given":"Deepika R","family":"Pai","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Damodar M","family":"Prabhu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Abdul","family":"Sameeh M","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ajay","family":"Soman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anjana","family":"Thomas","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anil Varghese","family":"Koruthu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","reference":[{"key":"ref1","article-title":"Treatment outcomes of patients with implant-supported fixed partial prostheses","volume":"13","author":"Wyatt CC","year":"1998","unstructured":"Wyatt CC, Zarb GA. Treatment outcomes of patients with implant-supported fixed partial prostheses. Int J Oral Maxillofac Implants. 1998, 13:204-11.","journal-title":"Int J Oral Maxillofac Implants"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1016\/s0022-3913(98)70106-4","article-title":"The influence of mandibular deformation, implant numbers, and loading position on detected forces in abutments supporting fixed implant superstructures","volume":"80","author":"Hobkirk JA","year":"1998","unstructured":"Hobkirk JA, Havthoulas TK. The influence of mandibular deformation, implant numbers, and loading position on detected forces in abutments supporting fixed implant superstructures. J Prosthet Dent. 1998, 80:169-74. 10.1016\/s0022-3913(98)70106-4","journal-title":"J Prosthet Dent"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1016\/0022-3913(83)90361-x","article-title":"Biomechanical considerations in osseointegrated prostheses","volume":"49","author":"Skalak R","year":"1983","unstructured":"Skalak R. Biomechanical considerations in osseointegrated prostheses. J Prosthet Dent. 1983, 49:843-8. 10.1016\/0022-3913(83)90361-x","journal-title":"J Prosthet Dent"},{"key":"ref4","unstructured":"Catalogs. (2024). Accessed. May 2, 2024: https:\/\/www.nobelbiocare.com\/en-us\/catalogs."},{"key":"ref5","article-title":"Influence of implant design and bone quality on stress\/strain distribution in bone around implants: a 3-dimensional finite element analysis","volume":"18","author":"Tada S","year":"2003","unstructured":"Tada S, Stegaroiu R, Kitamura E, Miyakawa O, Kusakari H. Influence of implant design and bone quality on stress\/strain distribution in bone around implants: a 3-dimensional finite element analysis. Int J Oral Maxillofac Implants. 2003, 18:357-68.","journal-title":"Int J Oral Maxillofac Implants"},{"key":"ref6","article-title":"Two dental implants designed for immediate loading: a finite element analysis","volume":"17","author":"Pierrisnard L","year":"2002","unstructured":"Pierrisnard L, Hure G, Barquins M, Chappard D. Two dental implants designed for immediate loading: a finite element analysis. Int J Oral Maxillofac Implants. 2002, 17:353-62.","journal-title":"Int J Oral Maxillofac Implants"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2003.08.008","article-title":"Influence of implant length and diameter on stress distribution: a finite element analysis","volume":"91","author":"Himmlov\u00e1 L","year":"2004","unstructured":"Himmlov\u00e1 L, Dost\u00e1lov\u00e1 T, K\u00e1covsk\u00fd A, Konvickov\u00e1 S. Influence of implant length and diameter on stress distribution: a finite element analysis. J Prosthet Dent. 2004, 91:20-5. 10.1016\/j.prosdent.2003.08.008","journal-title":"J Prosthet Dent"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1046\/j.1365-2842.2000.00475.x","article-title":"A biomechanical effect of wide implant placement and offset placement of three implants in the posterior partially edentulous region","volume":"27","author":"Sato Y","year":"2000","unstructured":"Sato Y, Shindoi N, Hosokawa R, Tsuga K, Akagawa Y. A biomechanical effect of wide implant placement and offset placement of three implants in the posterior partially edentulous region. J Oral Rehabil. 2000, 27:15-21. 10.1046\/j.1365-2842.2000.00475.x","journal-title":"J Oral Rehabil"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.1177\/00220345820610010501","article-title":"A three-dimensional finite element analysis of a porous rooted Co-Cr-Mo alloy dental implant","volume":"61","author":"Cook SD","year":"1982","unstructured":"Cook SD, Weinstein AM, Klawitter JJ. A three-dimensional finite element analysis of a porous rooted Co-Cr-Mo alloy dental implant. J Dent Res. 1982, 61:25-9. 10.1177\/00220345820610010501","journal-title":"J Dent Res"},{"key":"ref10","article-title":"A comparison of three-dimensional finite element stress analysis with in vitro strain gauge measurements on dental implants","volume":"15","author":"Ak\u00e7a K","year":"2002","unstructured":"Ak\u00e7a K, Cehreli MC, Iplik\u00e7ioglu H. A comparison of three-dimensional finite element stress analysis with in vitro strain gauge measurements on dental implants. Int J Prosthodont. 2002, 15:115-21.","journal-title":"Int J Prosthodont"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1016\/s0022-3913(96)90302-9","article-title":"The three-dimensional bone interface of an osseointegrated implant. I: A morphometric evaluation in initial healing","volume":"76","author":"Wadamoto M","year":"1996","unstructured":"Wadamoto M, Akagawa Y, Sato Y, Kubo T. The three-dimensional bone interface of an osseointegrated implant. I: A morphometric evaluation in initial healing.  J Prosthet Dent. 1996, 76:170-5. 10.1016\/s0022-3913(96)90302-9","journal-title":"J Prosthet Dent"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1054\/jcms.2000.0125","article-title":"Experimental and finite element study of a human mandible","volume":"28","author":"Vollmer D","year":"2000","unstructured":"Vollmer D, Meyer U, Joos U, V\u00e8gh A, Piffko J. Experimental and finite element study of a human mandible. J Craniomaxillofac Surg. 2000, 28:91-6. 10.1054\/jcms.2000.0125","journal-title":"J Craniomaxillofac Surg"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1046\/j.1365-2842.1998.00318.x","article-title":"Finite element analysis of non-axial versus axial loading of oral implants in the mandible of the dog","volume":"25","author":"Barbier L","year":"1998","unstructured":"Barbier L, Vander Sloten J, Krzesinski G, Schepers E, Van der Perre G. Finite element analysis of non-axial versus axial loading of oral implants in the mandible of the dog. J Oral Rehabil. 1998, 25:847-58. 10.1046\/j.1365-2842.1998.00318.x","journal-title":"J Oral Rehabil"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2003.09.012","article-title":"Finite element analysis to determine implant preload","volume":"90","author":"Lang LA","year":"2003","unstructured":"Lang LA, Kang B, Wang RF, Lang BR. Finite element analysis to determine implant preload. J Prosthet Dent. 2003, 90:539-46. 10.1016\/j.prosdent.2003.09.012","journal-title":"J Prosthet Dent"}],"container-title":["Cureus"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cureus.com\/articles\/259325-a-comparative-evaluation-of-stress-distribution-around-different-widths-of-implant-and-bony-interface-in-function-during-axial-and-non-axial-loading-a-finite-element-analysis","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,6,19]],"date-time":"2024-06-19T10:10:20Z","timestamp":1718791820000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cureus.com\/articles\/259325-a-comparative-evaluation-of-stress-distribution-around-different-widths-of-implant-and-bony-interface-in-function-during-axial-and-non-axial-loading-a-finite-element-analysis"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,6,19]]},"references-count":14,"URL":"https:\/\/doi.org\/10.7759\/cureus.62674","relation":{},"ISSN":["2168-8184"],"issn-type":[{"value":"2168-8184","type":"print"}],"subject":[],"published":{"date-parts":[[2024,6,19]]}}}