{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,7,10]],"date-time":"2024-07-10T00:24:37Z","timestamp":1720571077472},"reference-count":17,"publisher":"Springer Science and Business Media LLC","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2024,7,8]]},"DOI":"10.7759\/cureus.64119","type":"journal-article","created":{"date-parts":[[2024,7,9]],"date-time":"2024-07-09T05:38:29Z","timestamp":1720503509000},"source":"Crossref","is-referenced-by-count":0,"title":["Risk of Axillary Nerve Injury With Medial Support Screws in Intramedullary Nails: An Anatomical Study"],"prefix":"10.7759","author":[{"given":"Shunsuke","family":"Kobayashi","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Satoshi","family":"Miyake","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Terufumi","family":"Shibata","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kei","family":"Matsunaga","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Naofumi","family":"Hata","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Teruaki","family":"Izaki","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takuaki","family":"Yamamoto","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1097\/BOT.0b013e3180333094","article-title":"The importance of medial support in locked plating of proximal humerus fractures","volume":"21","author":"Gardner MJ","year":"2007","unstructured":"Gardner MJ, Weil Y, Barker JU, Kelly BT, Helfet DL, Lorich DG. The importance of medial support in locked plating of proximal humerus fractures. J Orthop Trauma. 2007, 21:185-91. 10.1097\/BOT.0b013e3180333094","journal-title":"J Orthop Trauma"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1097\/BOT.0000000000000057","article-title":"Effect of calcar screw use in surgical neck fractures of the proximal humerus with unstable medial support: a biomechanical study","volume":"28","author":"Bai L","year":"2014","unstructured":"Bai L, Fu Z, An S, Zhang P, Zhang D, Jiang B. Effect of calcar screw use in surgical neck fractures of the proximal humerus with unstable medial support: a biomechanical study. J Orthop Trauma. 2014, 28:452-7. 10.1097\/BOT.0000000000000057","journal-title":"J Orthop Trauma"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0103297","article-title":"The mechanical benefit of medial support screws in locking plating of proximal humerus fractures","volume":"9","author":"Zhang W","year":"2014","unstructured":"Zhang W, Zeng L, Liu Y, et al.. The mechanical benefit of medial support screws in locking plating of proximal humerus fractures. PLoS One. 2014, 9:e103297. 10.1371\/journal.pone.0103297","journal-title":"PLoS One"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1007\/s00264-011-1227-5","article-title":"The clinical benefit of medial support screws in locking plating of proximal humerus fractures: a prospective randomized study","volume":"35","author":"Zhang L","year":"2011","unstructured":"Zhang L, Zheng J, Wang W, et al.. The clinical benefit of medial support screws in locking plating of proximal humerus fractures: a prospective randomized study. Int Orthop. 2011, 35:1655-61. 10.1007\/s00264-011-1227-5","journal-title":"Int Orthop"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1097\/TA.0b013e3181beed96","article-title":"The biomechanics of locked plating for repairing proximal humerus fractures with or without medial cortical support","volume":"69","author":"Lescheid J","year":"2010","unstructured":"Lescheid J, Zdero R, Shah S, Kuzyk PR, Schemitsch EH. The biomechanics of locked plating for repairing proximal humerus fractures with or without medial cortical support. J Trauma. 2010, 69:1235-42. 10.1097\/TA.0b013e3181beed96","journal-title":"J Trauma"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1016\/j.jos.2021.11.004","article-title":"The use of medial support screw was associated with axillary nerve injury after plate fixation of proximal humeral fracture using minimal invasive deltoid-splitting approach","volume":"28","author":"Jeon N","year":"2023","unstructured":"Jeon N, Park S, Bae KH, Park KC, Hwang Bo BH, Lim TK. The use of medial support screw was associated with axillary nerve injury after plate fixation of proximal humeral fracture using minimal invasive deltoid-splitting approach. J Orthop Sci. 2023, 28:432-7. 10.1016\/j.jos.2021.11.004","journal-title":"J Orthop Sci"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1016\/j.jse.2019.01.019","article-title":"A new risk to the axillary nerve during percutaneous proximal humeral plate fixation using the Synthes PHILOS\u00a0aiming system","volume":"28","author":"Dang KH","year":"2019","unstructured":"Dang KH, Ornell SS, Reyes G, Hussey M, Dutta AK. A new risk to the axillary nerve during percutaneous proximal humeral plate fixation using the Synthes PHILOS\u00a0aiming system. J Shoulder Elbow Surg. 2019, 28:1795-800. 10.1016\/j.jse.2019.01.019","journal-title":"J Shoulder Elbow Surg"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1016\/j.jse.2010.05.010","article-title":"Surgical anatomy of the axillary nerve and its implication in the transdeltoid approaches to the shoulder","volume":"19","author":"Stecco C","year":"2010","unstructured":"Stecco C, Gagliano G, Lancerotto L, et al.. Surgical anatomy of the axillary nerve and its implication in the transdeltoid approaches to the shoulder. J Shoulder Elbow Surg. 2010, 19:1166-74. 10.1016\/j.jse.2010.05.010","journal-title":"J Shoulder Elbow Surg"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2006.08.025","article-title":"Percutaneous insertion of a proximal humeral locking plate: an anatomic study","volume":"38","author":"Smith J","year":"2007","unstructured":"Smith J, Berry G, Laflamme Y, Blain-Pare E, Reindl R, Harvey E. Percutaneous insertion of a proximal humeral locking plate: an anatomic study. Injury. 2007, 38:206-11. 10.1016\/j.injury.2006.08.025","journal-title":"Injury"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.55095\/achot2014\/007","article-title":"[Anatomy notes on minimally invasive plate osteosynthesis of the proximal humerus. A cadaver study]","volume":"81","author":"K\u0159ivohl\u00e1vek M","year":"2014","unstructured":"K\u0159ivohl\u00e1vek M, Taller S, Luk\u00e1\u0161 R, Dr\u00e1\u010d P. [Anatomy notes on minimally invasive plate osteosynthesis of the proximal humerus. A cadaver study]. Acta Chir Orthop Traumatol Cech. 2014, 81:63-9. 10.55095\/achot2014\/007","journal-title":"Acta Chir Orthop Traumatol Cech"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2010.04.014","article-title":"Risk of axillary nerve injury during percutaneous proximal humerus locking plate insertion using an external aiming guide","volume":"41","author":"Saran N","year":"2010","unstructured":"Saran N, Bergeron SG, Benoit B, Reindl R, Harvey EJ, Berry GK. Risk of axillary nerve injury during percutaneous proximal humerus locking plate insertion using an external aiming guide. Injury. 2010, 41:1037-40. 10.1016\/j.injury.2010.04.014","journal-title":"Injury"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.3944\/AOTT.2014.13.0083","article-title":"Relationship between axillary nerve and percutaneously inserted proximal humeral locking plate: a cadaver study","volume":"48","author":"Esenyel CZ","year":"2014","unstructured":"Esenyel CZ, Dedeo\u011flu S, Imren Y, Kahraman S, \u00c7akar M, \u00d6zt\u00fcrk K. Relationship between axillary nerve and percutaneously inserted proximal humeral locking plate: a cadaver study. Acta Orthop Traumatol Turc. 2014, 48:553-7. 10.3944\/AOTT.2014.13.0083","journal-title":"Acta Orthop Traumatol Turc"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.E.01375","article-title":"Is there a safe area for the axillary nerve in the deltoid muscle? A cadaveric study","volume":"88","author":"Cetik O","year":"2006","unstructured":"Cetik O, Uslu M, Acar HI, Comert A, Tekdemir I, Cift H. Is there a safe area for the axillary nerve in the deltoid muscle? A cadaveric study. J Bone Joint Surg Am. 2006, 88:2395-9. 10.2106\/JBJS.E.01375","journal-title":"J Bone Joint Surg Am"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.1186\/1754-9493-2-33","article-title":"Intramedullary fixation of proximal humerus fractures: do locking bolts endanger the axillary nerve or the ascending branch of the anterior circumflex artery? A cadaveric study","volume":"2","author":"Nijs S","year":"2008","unstructured":"Nijs S, Sermon A, Broos P. Intramedullary fixation of proximal humerus fractures: do locking bolts endanger the axillary nerve or the ascending branch of the anterior circumflex artery? A cadaveric study. Patient Saf Surg. 2008, 2:33. 10.1186\/1754-9493-2-33","journal-title":"Patient Saf Surg"},{"key":"ref15","doi-asserted-by":"publisher","DOI":"10.1097\/00005131-200410000-00001","article-title":"The relationship of proximal locking screws to the axillary nerve during antegrade humeral nail insertion of four commercially available implants","volume":"18","author":"Prince EJ","year":"2004","unstructured":"Prince EJ, Breien KM, Fehringer EV, Mormino MA. The relationship of proximal locking screws to the axillary nerve during antegrade humeral nail insertion of four commercially available implants. J Orthop Trauma. 2004, 18:585-8. 10.1097\/00005131-200410000-00001","journal-title":"J Orthop Trauma"},{"key":"ref16","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2014.05.006","article-title":"Risk of injury to the axillary nerve during antegrade proximal humeral blade nail fixation - an anatomical study","volume":"45","author":"Spiegelberg BG","year":"2014","unstructured":"Spiegelberg BG, Riley ND, Taylor GJ. Risk of injury to the axillary nerve during antegrade proximal humeral blade nail fixation - an anatomical study. Injury. 2014, 45:1185-9. 10.1016\/j.injury.2014.05.006","journal-title":"Injury"},{"key":"ref17","doi-asserted-by":"publisher","DOI":"10.5005\/jp-journals-10080-1460","article-title":"Use of the humeral head as a reference point to prevent axillary nerve damage during proximal fixation of humeral fractures: an anatomical and radiographic study","volume":"15","author":"Theeuwes HP","year":"2020","unstructured":"Theeuwes HP, Potters JW, Bessems J, Kerver AJ, Kleinrensink GJ. Use of the humeral head as a reference point to prevent axillary nerve damage during proximal fixation of humeral fractures: an anatomical and radiographic study. Strategies Trauma Limb Reconstr. 2020, 15:63-8. 10.5005\/jp-journals-10080-1460","journal-title":"Strategies Trauma Limb Reconstr"}],"container-title":["Cureus"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cureus.com\/articles\/256659-risk-of-axillary-nerve-injury-with-medial-support-screws-in-intramedullary-nails-an-anatomical-study","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,7,9]],"date-time":"2024-07-09T05:38:31Z","timestamp":1720503511000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cureus.com\/articles\/256659-risk-of-axillary-nerve-injury-with-medial-support-screws-in-intramedullary-nails-an-anatomical-study"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,7,8]]},"references-count":17,"URL":"https:\/\/doi.org\/10.7759\/cureus.64119","relation":{},"ISSN":["2168-8184"],"issn-type":[{"value":"2168-8184","type":"print"}],"subject":[],"published":{"date-parts":[[2024,7,8]]}}}