{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,23]],"date-time":"2025-12-23T15:40:36Z","timestamp":1766504436638},"reference-count":37,"publisher":"Springer Science and Business Media LLC","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2024,7,30]]},"DOI":"10.7759\/cureus.65769","type":"journal-article","created":{"date-parts":[[2024,7,30]],"date-time":"2024-07-30T17:52:26Z","timestamp":1722361946000},"source":"Crossref","is-referenced-by-count":3,"title":["The Utilization of Brillouin Microscopy in Corneal Diagnostics: A Systematic Review"],"prefix":"10.7759","author":[{"given":"Bosten A","family":"Loveless","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kayvon A","family":"Moin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Phillip C","family":"Hoopes","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Majid","family":"Moshirfar","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.4103\/ijo.IJO_646_17","article-title":"Anatomy of cornea and ocular surface","volume":"66","author":"Sridhar MS","year":"2018","unstructured":"Sridhar MS. Anatomy of cornea and ocular surface. Indian J Ophthalmol. 2018, 66:190-4. 10.4103\/ijo.IJO_646_17","journal-title":"Indian J Ophthalmol"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.3389\/fcell.2020.00731","article-title":"Distribution and function of glycosaminoglycans and proteoglycans in the development, homeostasis and pathology of the ocular surface","volume":"8","author":"Puri S","year":"2020","unstructured":"Puri S, Coulson-Thomas YM, Gesteira TF, Coulson-Thomas VJ. Distribution and function of glycosaminoglycans and proteoglycans in the development, homeostasis and pathology of the ocular surface. Front Cell Dev Biol. 2020, 8:731. 10.3389\/fcell.2020.00731","journal-title":"Front Cell Dev Biol"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2004.10.044","article-title":"Determining in vivo biomechanical properties of the cornea with an ocular response analyzer","volume":"31","author":"Luce DA","year":"2005","unstructured":"Luce DA. Determining in vivo biomechanical properties of the cornea with an ocular response analyzer. J Cataract Refract Surg. 2005, 31:156-62. 10.1016\/j.jcrs.2004.10.044","journal-title":"J Cataract Refract Surg"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.04-0694","article-title":"Assessment of the biomechanical properties of the cornea with the ocular response analyzer in normal and keratoconic eyes","volume":"48","author":"Shah S","year":"2007","unstructured":"Shah S, Laiquzzaman M, Bhojwani R, Mantry S, Cunliffe I. Assessment of the biomechanical properties of the cornea with the ocular response analyzer in normal and keratoconic eyes. Invest Ophthalmol Vis Sci. 2007, 48:3026-31. 10.1167\/iovs.04-0694","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.2147\/OPTH.S236114","article-title":"Corneal hysteresis as a biomarker of glaucoma: current insights","volume":"14","author":"Zimprich L","year":"2020","unstructured":"Zimprich L, Diedrich J, Bleeker A, Schweitzer JA. Corneal hysteresis as a biomarker of glaucoma: current insights. Clin Ophthalmol. 2020, 14:2255-64. 10.2147\/OPTH.S236114","journal-title":"Clin Ophthalmol"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.4103\/0974-620X.159255","article-title":"Ocular response analyzer parameters in healthy, keratoconus suspect and manifest keratoconus eyes","volume":"8","author":"Mohammadpour M","year":"2015","unstructured":"Mohammadpour M, Etesami I, Yavari Z, Naderan M, Abdollahinia F, Jabbarvand M. Ocular response analyzer parameters in healthy, keratoconus suspect and manifest keratoconus eyes. Oman J Ophthalmol. 2015, 8:102-6. 10.4103\/0974-620X.159255","journal-title":"Oman J Ophthalmol"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.4103\/0974-620X.111895","article-title":"Corneal biomechanics in iatrogenic ectasia and keratoconus: a review of the literature","volume":"6","author":"Moshirfar M","year":"2013","unstructured":"Moshirfar M, Edmonds JN, Behunin NL, Christiansen SM. Corneal biomechanics in iatrogenic ectasia and keratoconus: a review of the literature. Oman J Ophthalmol. 2013, 6:12-7. 10.4103\/0974-620X.111895","journal-title":"Oman J Ophthalmol"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1097\/ICU.0000000000000489","article-title":"Brillouin microscopy: assessing ocular tissue biomechanics","volume":"29","author":"Yun SH","year":"2018","unstructured":"Yun SH, Chernyak D. Brillouin microscopy: assessing ocular tissue biomechanics. Curr Opin Ophthalmol. 2018, 29:299-305. 10.1097\/ICU.0000000000000489","journal-title":"Curr Opin Ophthalmol"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20160629-01","article-title":"Detection of keratoconus with a new biomechanical index","volume":"32","author":"Vinciguerra R","year":"2016","unstructured":"Vinciguerra R, Ambr\u00f3sio R Jr, Elsheikh A, et al.. Detection of keratoconus with a new biomechanical index. J Refract Surg. 2016, 32:803-10. 10.3928\/1081597X-20160629-01","journal-title":"J Refract Surg"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20170426-02","article-title":"Integration of Scheimpflug-based corneal tomography and biomechanical assessments for enhancing ectasia detection","volume":"33","author":"Ambr\u00f3sio R Jr","year":"2017","unstructured":"Ambr\u00f3sio R Jr, Lopes BT, Faria-Correia F, et al.. Integration of Scheimpflug-based corneal tomography and biomechanical assessments for enhancing ectasia detection. J Refract Surg. 2017, 33:434-43. 10.3928\/1081597X-20170426-02","journal-title":"J Refract Surg"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.2214\/ajr.178.6.1781411","article-title":"MR elastography of breast cancer: preliminary results","volume":"178","author":"McKnight AL","year":"2002","unstructured":"McKnight AL, Kugel JL, Rossman PJ, Manduca A, Hartmann LC, Ehman RL. MR elastography of breast cancer: preliminary results. AJR Am J Roentgenol. 2002, 178:1411-7. 10.2214\/ajr.178.6.1781411","journal-title":"AJR Am J Roentgenol"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1016\/j.csbj.2023.04.009","article-title":"In vivo corneal elastography: a topical review of challenges and opportunities","volume":"21","author":"Lan G","year":"2023","unstructured":"Lan G, Twa MD, Song C, et al.. In vivo corneal elastography: a topical review of challenges and opportunities. Comput Struct Biotechnol J. 2023, 21:2664-87. 10.1016\/j.csbj.2023.04.009","journal-title":"Comput Struct Biotechnol J"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1208\/s12249-019-1311-5","article-title":"Brillouin light scattering: development of a near century-old technique for characterizing the mechanical properties of materials","volume":"20","author":"Singaraju AB","year":"2019","unstructured":"Singaraju AB, Bahl D, Stevens LL. Brillouin light scattering: development of a near century-old technique for characterizing the mechanical properties of materials. AAPS PharmSciTech. 2019, 20:109. 10.1208\/s12249-019-1311-5","journal-title":"AAPS PharmSciTech"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.1098\/rspb.1982.0021","article-title":"The measurement and interpretation of Brillouin scattering in the lens of the eye","volume":"214","author":"Randall J","year":"1982","unstructured":"Randall J, Vaughan JM. The measurement and interpretation of Brillouin scattering in the lens of the eye. Proc R Soc Lond B Biol Sci. 1982, 214:449-70. 10.1098\/rspb.1982.0021","journal-title":"Proc R Soc Lond B Biol Sci"},{"key":"ref15","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2004.09.031","article-title":"Influence of corneal biomechanical properties on intraocular pressure measurement: quantitative analysis","volume":"31","author":"Liu J","year":"2005","unstructured":"Liu J, Roberts CJ. Influence of corneal biomechanical properties on intraocular pressure measurement: quantitative analysis. J Cataract Refract Surg. 2005, 31:146-55. 10.1016\/j.jcrs.2004.09.031","journal-title":"J Cataract Refract Surg"},{"key":"ref16","doi-asserted-by":"publisher","DOI":"10.1007\/s12551-020-00701-9","article-title":"Recent progress and current opinions in Brillouin microscopy for life science applications","volume":"12","author":"Antonacci G","year":"2020","unstructured":"Antonacci G, Beck T, Bilenca A, et al.. Recent progress and current opinions in Brillouin microscopy for life science applications. Biophys Rev. 2020, 12:615-24. 10.1007\/s12551-020-00701-9","journal-title":"Biophys Rev"},{"key":"ref17","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.11-8611","article-title":"Depth-dependent transverse shear properties of the human corneal stroma","volume":"53","author":"Petsche SJ","year":"2012","unstructured":"Petsche SJ, Chernyak D, Martiz J, Levenston ME, Pinsky PM. Depth-dependent transverse shear properties of the human corneal stroma. Invest Ophthalmol Vis Sci. 2012, 53:873-80. 10.1167\/iovs.11-8611","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"ref18","doi-asserted-by":"publisher","DOI":"10.1155\/2018\/5392041","article-title":"Preliminary investigation of the mechanical anisotropy of the normal human corneal stroma","volume":"2018","author":"Xue C","year":"2018","unstructured":"Xue C, Xiang Y, Shen M, Wu D, Wang Y. Preliminary investigation of the mechanical anisotropy of the normal human corneal stroma. J Ophthalmol. 2018, 2018:5392041. 10.1155\/2018\/5392041","journal-title":"J Ophthalmol"},{"key":"ref19","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.11-8281","article-title":"Brillouin optical microscopy for corneal biomechanics","volume":"53","author":"Scarcelli G","year":"2012","unstructured":"Scarcelli G, Pineda R, Yun SH. Brillouin optical microscopy for corneal biomechanics. Invest Ophthalmol Vis Sci. 2012, 53:185-90. 10.1167\/iovs.11-8281","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"ref20","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.12-11509","article-title":"Collagen cross-linking using rose bengal and green light to increase corneal stiffness","volume":"54","author":"Cherfan D","year":"2013","unstructured":"Cherfan D, Verter EE, Melki S, et al.. Collagen cross-linking using rose bengal and green light to increase corneal stiffness. Invest Ophthalmol Vis Sci. 2013, 54:3426-33. 10.1167\/iovs.12-11509","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"ref21","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.14-14450","article-title":"Biomechanical characterization of keratoconus corneas ex vivo with Brillouin microscopy","volume":"55","author":"Scarcelli G","year":"2014","unstructured":"Scarcelli G, Besner S, Pineda R, Yun SH. Biomechanical characterization of keratoconus corneas ex vivo with Brillouin microscopy. Invest Ophthalmol Vis Sci. 2014, 55:4490-5. 10.1167\/iovs.14-14450","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"ref22","doi-asserted-by":"publisher","DOI":"10.1039\/c5fd00152h","article-title":"Assessing corneal biomechanics with Brillouin spectro-microscopy","volume":"187","author":"Lepert G","year":"2016","unstructured":"Lepert G, Gouveia RM, Connon CJ, Paterson C. Assessing corneal biomechanics with Brillouin spectro-microscopy. Faraday Discuss. 2016, 187:415-28. 10.1039\/c5fd00152h","journal-title":"Faraday Discuss"},{"key":"ref23","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20170421-01","article-title":"Biomechanical changes after LASIK flap creation combined with rapid cross-linking measured with Brillouin microscopy","volume":"33","author":"Randleman JB","year":"2017","unstructured":"Randleman JB, Su JP, Scarcelli G. Biomechanical changes after LASIK flap creation combined with rapid cross-linking measured with Brillouin microscopy. J Refract Surg. 2017, 33:408-14. 10.3928\/1081597X-20170421-01","journal-title":"J Refract Surg"},{"key":"ref24","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20190304-01","article-title":"Biomechanical impact of localized corneal cross-linking beyond the irradiated treatment area","volume":"35","author":"Webb JN","year":"2019","unstructured":"Webb JN, Langille E, Hafezi F, Randleman JB, Scarcelli G. Biomechanical impact of localized corneal cross-linking beyond the irradiated treatment area. J Refract Surg. 2019, 35:253-60. 10.3928\/1081597X-20190304-01","journal-title":"J Refract Surg"},{"key":"ref25","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20191004-01","article-title":"Depth-dependent reduction of biomechanical efficacy of contact lens-assisted corneal cross-linking analyzed by Brillouin microscopy","volume":"35","author":"Zhang H","year":"2019","unstructured":"Zhang H, Roozbahani M, Piccinini AL, Golan O, Hafezi F, Scarcelli G, Randleman JB. Depth-dependent reduction of biomechanical efficacy of contact lens-assisted corneal cross-linking analyzed by Brillouin microscopy. J Refract Surg. 2019, 35:721-8. 10.3928\/1081597X-20191004-01","journal-title":"J Refract Surg"},{"key":"ref26","doi-asserted-by":"publisher","DOI":"10.1167\/tvst.9.7.26","article-title":"Detecting mechanical anisotropy of the cornea using Brillouin microscopy","volume":"9","author":"Webb JN","year":"2020","unstructured":"Webb JN, Zhang H, Sinha Roy A, Randleman JB, Scarcelli G. Detecting mechanical anisotropy of the cornea using Brillouin microscopy. Transl Vis Sci Technol. 2020, 9:26. 10.1167\/tvst.9.7.26","journal-title":"Transl Vis Sci Technol"},{"key":"ref27","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000000294","article-title":"Brillouin microscopic depth-dependent analysis of corneal crosslinking performed over or under the LASIK flap","volume":"46","author":"Zhang H","year":"2020","unstructured":"Zhang H, Roozbahani M, Piccinini AL, Hafezi F, Scarcelli G, Randleman JB. Brillouin microscopic depth-dependent analysis of corneal crosslinking performed over or under the LASIK flap. J Cataract Refract Surg. 2020, 46:1543-7. 10.1097\/j.jcrs.0000000000000294","journal-title":"J Cataract Refract Surg"},{"key":"ref28","doi-asserted-by":"publisher","DOI":"10.1038\/s41467-022-29038-5","article-title":"Measuring mechanical anisotropy of the cornea with Brillouin microscopy","volume":"13","author":"Eltony AM","year":"2022","unstructured":"Eltony AM, Shao P, Yun SH. Measuring mechanical anisotropy of the cornea with Brillouin microscopy. Nat Commun. 2022, 13:1354. 10.1038\/s41467-022-29038-5","journal-title":"Nat Commun"},{"key":"ref29","doi-asserted-by":"publisher","DOI":"10.1364\/OE.20.009197","article-title":"In vivo Brillouin optical microscopy of the human eye","volume":"20","author":"Scarcelli G","year":"2012","unstructured":"Scarcelli G, Yun SH. In vivo Brillouin optical microscopy of the human eye. Opt Express. 2012, 20:9197-202. 10.1364\/OE.20.009197","journal-title":"Opt Express"},{"key":"ref30","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-019-43811-5","article-title":"Spatially-resolved Brillouin spectroscopy reveals biomechanical abnormalities in mild to advanced keratoconus in vivo","volume":"9","author":"Shao P","year":"2019","unstructured":"Shao P, Eltony AM, Seiler TG, et al.. Spatially-resolved Brillouin spectroscopy reveals biomechanical abnormalities in mild to advanced keratoconus in vivo. Sci Rep. 2019, 9:7467. 10.1038\/s41598-019-43811-5","journal-title":"Sci Rep"},{"key":"ref31","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2019.02.010","article-title":"Brillouin spectroscopy of normal and keratoconus corneas","volume":"202","author":"Seiler TG","year":"2019","unstructured":"Seiler TG, Shao P, Eltony A, Seiler T, Yun SH. Brillouin spectroscopy of normal and keratoconus corneas. Am J Ophthalmol. 2019, 202:118-25. 10.1016\/j.ajo.2019.02.010","journal-title":"Am J Ophthalmol"},{"key":"ref32","doi-asserted-by":"publisher","DOI":"10.1364\/BOE.472053","article-title":"Motion-tracking Brillouin microscopy for in-vivo corneal biomechanics mapping","volume":"13","author":"Zhang H","year":"2022","unstructured":"Zhang H, Asroui L, Randleman JB, Scarcelli G. Motion-tracking Brillouin microscopy for in-vivo corneal biomechanics mapping. Biomed Opt Express. 2022, 13:6196-210. 10.1364\/BOE.472053","journal-title":"Biomed Opt Express"},{"key":"ref33","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2023.03.018","article-title":"Motion-tracking Brillouin microscopy evaluation of normal, keratoconic, and post-laser vision correction corneas","volume":"254","author":"Zhang H","year":"2023","unstructured":"Zhang H, Asroui L, Tarib I, Dupps WJ Jr, Scarcelli G, Randleman JB. Motion-tracking Brillouin microscopy evaluation of normal, keratoconic, and post-laser vision correction corneas. Am J Ophthalmol. 2023, 254:128-40. 10.1016\/j.ajo.2023.03.018","journal-title":"Am J Ophthalmol"},{"key":"ref34","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2023.10.011","article-title":"Subclinical keratoconus detection and characterization using motion-tracking Brillouin microscopy","volume":"131","author":"Randleman JB","year":"2024","unstructured":"Randleman JB, Zhang H, Asroui L, Tarib I, Dupps WJ Jr, Scarcelli G. Subclinical keratoconus detection and characterization using motion-tracking Brillouin microscopy. Ophthalmology. 2024, 131:310-21. 10.1016\/j.ophtha.2023.10.011","journal-title":"Ophthalmology"},{"key":"ref35","doi-asserted-by":"publisher","DOI":"10.1364\/OL.453996","article-title":"Multimodal imaging system combining optical coherence tomography and Brillouin microscopy for neural tube imaging","volume":"47","author":"Ambekar YS","year":"2022","unstructured":"Ambekar YS, Singh M, Schill AW, et al.. Multimodal imaging system combining optical coherence tomography and Brillouin microscopy for neural tube imaging. Opt Lett. 2022, 47:1347-50. 10.1364\/OL.453996","journal-title":"Opt Lett"},{"key":"ref36","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2009.09.023","article-title":"Corneal biomechanical metrics and anterior segment parameters in mild keratoconus","volume":"117","author":"Fontes BM","year":"2010","unstructured":"Fontes BM, Ambr\u00f3sio R Jr, Jardim D, Velarde GC, Nos\u00e9 W. Corneal biomechanical metrics and anterior segment parameters in mild keratoconus. Ophthalmology. 2010, 117:673-9. 10.1016\/j.ophtha.2009.09.023","journal-title":"Ophthalmology"},{"key":"ref37","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.18-24228","article-title":"Effects of corneal hydration on Brillouin microscopy in vivo","volume":"59","author":"Shao P","year":"2018","unstructured":"Shao P, Seiler TG, Eltony AM, et al.. Effects of corneal hydration on Brillouin microscopy in vivo. Invest Ophthalmol Vis Sci. 2018, 59:3020-7. 10.1167\/iovs.18-24228","journal-title":"Invest Ophthalmol Vis Sci"}],"container-title":["Cureus"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cureus.com\/articles\/276718-the-utilization-of-brillouin-microscopy-in-corneal-diagnostics-a-systematic-review","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,7,30]],"date-time":"2024-07-30T17:52:30Z","timestamp":1722361950000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cureus.com\/articles\/276718-the-utilization-of-brillouin-microscopy-in-corneal-diagnostics-a-systematic-review"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,7,30]]},"references-count":37,"URL":"https:\/\/doi.org\/10.7759\/cureus.65769","relation":{},"ISSN":["2168-8184"],"issn-type":[{"value":"2168-8184","type":"print"}],"subject":[],"published":{"date-parts":[[2024,7,30]]}}}