{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,9]],"date-time":"2026-06-09T15:32:29Z","timestamp":1781019149851,"version":"3.54.1"},"reference-count":17,"publisher":"Springer Science and Business Media LLC","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2024,8,26]]},"DOI":"10.7759\/cureus.67863","type":"journal-article","created":{"date-parts":[[2024,8,27]],"date-time":"2024-08-27T01:53:13Z","timestamp":1724723593000},"source":"Crossref","is-referenced-by-count":1,"title":["Gastric Tube Insertion Performance of Second-Generation Supraglottic Airway Devices: A Prospective Manikin Study With Literature Review"],"prefix":"10.7759","author":[{"given":"Yoshiya","family":"Adachi","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mineto","family":"Kamata","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Akira","family":"Kitamura","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1097\/ALN.0000000000004002","article-title":"2022 American Society of Anesthesiologists practice guidelines for management of the difficult airway","volume":"136","author":"Apfelbaum JL","year":"2022","unstructured":"Apfelbaum JL, Hagberg CA, Connis RT, et al.. 2022 American Society of Anesthesiologists practice guidelines for management of the difficult airway. Anesthesiology. 2022, 136:31-81. 10.1097\/ALN.0000000000004002","journal-title":"Anesthesiology"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jclinane.2018.12.044","article-title":"Comparison of supraglottic airway devices in laparoscopic surgeries: a network meta-analysis","volume":"55","author":"Yoon SW","year":"2019","unstructured":"Yoon SW, Kang H, Choi GJ, et al.. Comparison of supraglottic airway devices in laparoscopic surgeries: a network meta-analysis. J Clin Anesth. 2019, 55:52-66. 10.1016\/j.jclinane.2018.12.044","journal-title":"J Clin Anesth"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.4103\/ija.IJA_153_18","article-title":"A comparative evaluation of ProSeal laryngeal mask airway, I-gel and Supreme laryngeal mask airway in adult patients undergoing elective surgery: a randomised trial","volume":"62","author":"Singh A","year":"2018","unstructured":"Singh A, Bhalotra AR, Anand R. A comparative evaluation of ProSeal laryngeal mask airway, I-gel and Supreme laryngeal mask airway in adult patients undergoing elective surgery: a randomised trial. Indian J Anaesth. 2018, 62:858-64. 10.4103\/ija.IJA_153_18","journal-title":"Indian J Anaesth"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.4236\/ojanes.2014.412047","article-title":"Cross-over assessment of the Ambu AuraGain, LMA Supreme New Cuff and Intersurgical I-Gel in fresh cadavers","volume":"4","author":"Lopez AM","year":"2014","unstructured":"Lopez AM, Sala-Blanch X, Valero R, Prats A. Cross-over assessment of the Ambu AuraGain, LMA Supreme New Cuff and Intersurgical I-Gel in fresh cadavers. Open J Anesthesiol. 2014, 4:332-9. 10.4236\/ojanes.2014.412047","journal-title":"Open J Anesthesiol"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.2010.06534.x","article-title":"Comparison of the LMA Supreme vs the i-gel in paralysed patients undergoing gynaecological laparoscopic surgery with controlled ventilation","volume":"65","author":"Teoh WH","year":"2010","unstructured":"Teoh WH, Lee KM, Suhitharan T, Yahaya Z, Teo MM, Sia AT. Comparison of the LMA Supreme vs the i-gel in paralysed patients undergoing gynaecological laparoscopic surgery with controlled ventilation. Anaesthesia. 2010, 65:1173-9. 10.1111\/j.1365-2044.2010.06534.x","journal-title":"Anaesthesia"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1016\/s0034-9356(09)70437-2","article-title":"Supreme laryngeal mask airway vs the I-gel supraglottic airway in patients under general anesthesia and mechanical ventilation with no neuromuscular block: a randomized clinical trial. (Article in Spanish)","volume":"56","author":"Fern\u00e1ndez D\u00edez A","year":"2009","unstructured":"Fern\u00e1ndez D\u00edez A, P\u00e9rez Villafa\u00f1e A, Bermejo Gonz\u00e1lez JC, Marcos Vidal JM. Supreme laryngeal mask airway vs the I-gel supraglottic airway in patients under general anesthesia and mechanical ventilation with no neuromuscular block: a randomized clinical trial. (Article in Spanish). Rev Esp Anestesiol Reanim. 2009, 56:474-8. 10.1016\/s0034-9356(09)70437-2","journal-title":"Rev Esp Anestesiol Reanim"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.4097\/kjae.2015.68.5.455","article-title":"Comparison of i-gel\u00ae and LMA Supreme\u00ae during laparoscopic cholecystectomy","volume":"68","author":"Park SY","year":"2015","unstructured":"Park SY, Rim JC, Kim H, Lee JH, Chung CJ. Comparison of i-gel\u00ae and LMA Supreme\u00ae during laparoscopic cholecystectomy. Korean J Anesthesiol. 2015, 68:455-61. 10.4097\/kjae.2015.68.5.455","journal-title":"Korean J Anesthesiol"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1177\/0310057X1704500215","article-title":"Ambu\u00ae AuraGain\u2122 versus LMA Supreme\u2122 Second Seal\u2122: a randomised controlled trial comparing oropharyngeal leak pressures and gastric drain functionality in spontaneously breathing patients","volume":"45","author":"Shariffuddin II","year":"2017","unstructured":"Shariffuddin II, Teoh WH, Tang E, Hashim N, Loh PS. Ambu\u00ae AuraGain\u2122 versus LMA Supreme\u2122 Second Seal\u2122: a randomised controlled trial comparing oropharyngeal leak pressures and gastric drain functionality in spontaneously breathing patients. Anaesth Intensive Care. 2017, 45:244-50. 10.1177\/0310057X1704500215","journal-title":"Anaesth Intensive Care"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.23736\/S0375-9393.20.14237-8","article-title":"Comparison of the i-gel\u2122 with the AuraGain\u2122 laryngeal mask airways in patients with a simulated cervical immobilization: a randomized controlled trial","volume":"86","author":"Hur M","year":"2020","unstructured":"Hur M, Choi S, Row HS, Kim TK. Comparison of the i-gel\u2122 with the AuraGain\u2122 laryngeal mask airways in patients with a simulated cervical immobilization: a randomized controlled trial. Minerva Anestesiol. 2020, 86:727-35. 10.23736\/S0375-9393.20.14237-8","journal-title":"Minerva Anestesiol"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.1111\/j.1399-6576.2009.01986.x","article-title":"A new supraglottic airway device: LMA-Supreme, comparison with LMA-ProSeal","volume":"53","author":"Hosten T","year":"2009","unstructured":"Hosten T, Gurkan Y, Ozdamar D, Tekin M, Toker K, Solak M. A new supraglottic airway device: LMA-Supreme, comparison with LMA-ProSeal. Acta Anaesthesiol Scand. 2009, 53:852-7. 10.1111\/j.1399-6576.2009.01986.x","journal-title":"Acta Anaesthesiol Scand"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1055\/s-2005-870103","article-title":"The applicability of the ProSeal laryngeal mask airway for laparotomies. (Article in German)","volume":"40","author":"Borkowski A","year":"2005","unstructured":"Borkowski A, Perl T, Heuer J, Timmermann A, Braun U. The applicability of the ProSeal laryngeal mask airway for laparotomies. (Article in German). Anasthesiol Intensivmed Notfallmed Schmerzther. 2005, 40:477-86. 10.1055\/s-2005-870103","journal-title":"Anasthesiol Intensivmed Notfallmed Schmerzther"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.23736\/S0375-9393.16.11112-5","article-title":"LMA Supreme\u2122 and Ambu\u00ae AuraGain\u2122 in anesthetized adult patients: a prospective observational study","volume":"83","author":"Kriege M","year":"2017","unstructured":"Kriege M, Piepho T, Zanker S, Alflen C, Heid F, Noppens RR. LMA Supreme\u2122 and Ambu\u00ae AuraGain\u2122 in anesthetized adult patients: a prospective observational study. Minerva Anestesiol. 2017, 83:165-74. 10.23736\/S0375-9393.16.11112-5","journal-title":"Minerva Anestesiol"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0278871","article-title":"Contrast of oropharyngeal leak pressure and clinical performance of I-gel\u2122 and LMA ProSeal\u2122 in patients: a meta-analysis","volume":"17","author":"Tan Y","year":"2022","unstructured":"Tan Y, Jiang J, Wang R. Contrast of oropharyngeal leak pressure and clinical performance of I-gel\u2122 and LMA ProSeal\u2122 in patients: a meta-analysis. PLoS One. 2022, 17:e0278871. 10.1371\/journal.pone.0278871","journal-title":"PLoS One"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/aer058","article-title":"Major complications of airway management in the UK: results of the Fourth National Audit Project of the Royal College of Anaesthetists and the Difficult Airway Society. Part 1: anaesthesia","volume":"106","author":"Cook TM","year":"2011","unstructured":"Cook TM, Woodall N, Frerk C. Major complications of airway management in the UK: results of the Fourth National Audit Project of the Royal College of Anaesthetists and the Difficult Airway Society. Part 1: anaesthesia. Br J Anaesth. 2011, 106:617-31. 10.1093\/bja\/aer058","journal-title":"Br J Anaesth"},{"key":"ref15","doi-asserted-by":"publisher","DOI":"10.1007\/BF03022507","article-title":"Suction catheter guided insertion of the ProSeal laryngeal mask airway is superior to the digital technique","volume":"53","author":"Garc\u00eda-Aguado R","year":"2006","unstructured":"Garc\u00eda-Aguado R, Vi\u00f1oles J, Brimacombe J, Viv\u00f3 M, L\u00f3pez-Estudillo R, Ayala G. Suction catheter guided insertion of the ProSeal laryngeal mask airway is superior to the digital technique. Can J Anaesth. 2006, 53:398-403. 10.1007\/BF03022507","journal-title":"Can J Anaesth"},{"key":"ref16","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/aer104","article-title":"Comparison of the LMA Supreme\u2122 with the LMA Proseal\u2122 for airway management in patients anaesthetized in prone position","volume":"107","author":"L\u00f3pez AM","year":"2011","unstructured":"L\u00f3pez AM, Valero R, Hurtado P, Gamb\u00fas P, Pons M, Anglada T. Comparison of the LMA Supreme\u2122 with the LMA Proseal\u2122 for airway management in patients anaesthetized in prone position. Br J Anaesth. 2011, 107:265-71. 10.1093\/bja\/aer104","journal-title":"Br J Anaesth"},{"key":"ref17","doi-asserted-by":"publisher","DOI":"10.2147\/TCRM.S194728","article-title":"Comprehensive evaluation of manikin-based airway training with second generation supraglottic airway devices","volume":"15","author":"Schmutz A","year":"2019","unstructured":"Schmutz A, Bohn E, Spaeth J, Heinrich S. Comprehensive evaluation of manikin-based airway training with second generation supraglottic airway devices. Ther Clin Risk Manag. 2019, 15:367-76. 10.2147\/TCRM.S194728","journal-title":"Ther Clin Risk Manag"}],"container-title":["Cureus"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cureus.com\/articles\/276739-gastric-tube-insertion-performance-of-second-generation-supraglottic-airway-devices-a-prospective-manikin-study-with-literature-review","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,8,27]],"date-time":"2024-08-27T01:53:16Z","timestamp":1724723596000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cureus.com\/articles\/276739-gastric-tube-insertion-performance-of-second-generation-supraglottic-airway-devices-a-prospective-manikin-study-with-literature-review"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,8,26]]},"references-count":17,"URL":"https:\/\/doi.org\/10.7759\/cureus.67863","relation":{},"ISSN":["2168-8184"],"issn-type":[{"value":"2168-8184","type":"print"}],"subject":[],"published":{"date-parts":[[2024,8,26]]}}}