{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,9,12]],"date-time":"2024-09-12T00:30:20Z","timestamp":1726101020272},"reference-count":26,"publisher":"Springer Science and Business Media LLC","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2024,9,11]]},"DOI":"10.7759\/cureus.69168","type":"journal-article","created":{"date-parts":[[2024,9,11]],"date-time":"2024-09-11T11:11:56Z","timestamp":1726053116000},"source":"Crossref","is-referenced-by-count":0,"title":["Macula Characteristics in Young Saudi Male Patients with Myopia: A Comparative Hospital-Based Study"],"prefix":"10.7759","author":[{"given":"Raghda F.","family":"Mutwaly","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Abdelaziz M.","family":"Elmadina","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Saif H.","family":"Alrasheed","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Majid A.","family":"Moafa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sulaiman","family":"Aldakhil","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.05-1380","article-title":"Myopia, axial length, and OCT characteristics of the macula in Singaporean children","volume":"47","author":"Luo HD","year":"2006","unstructured":"Luo HD, Gazzard G, Fong A, et al.. Myopia, axial length, and OCT characteristics of the macula in Singaporean children. Invest Ophthalmol Vis Sci. 2006, 47:2773-81. 10.1167\/iovs.05-1380","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.05-1396","article-title":"Distribution of macular thickness by optical coherence tomography: findings from a population-based study of 6-year-old children","volume":"47","author":"Huynh SC","year":"2006","unstructured":"Huynh SC, Wang XY, Rochtchina E, Mitchell P. Distribution of macular thickness by optical coherence tomography: findings from a population-based study of 6-year-old children. Invest Ophthalmol Vis Sci. 2006, 47:2351-7. 10.1167\/iovs.05-1396","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.4103\/ijo.IJO_863_16","article-title":"Insight into high myopia and the macula","volume":"65","author":"Kumar A","year":"2017","unstructured":"Kumar A, Chawla R, Kumawat D, Pillay G. Insight into high myopia and the macula. Indian J Ophthalmol. 2017, 65:85-91. 10.4103\/ijo.IJO_863_16","journal-title":"Indian J Ophthalmol"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.05-1589","article-title":"Human macula investigated in vivo with polarization-sensitive optical coherence tomography","volume":"47","author":"Pircher M","year":"2006","unstructured":"Pircher M, G\u00f6tzinger E, Findl O, et al.. Human macula investigated in vivo with polarization-sensitive optical coherence tomography. Invest Ophthalmol Vis Sci. 2006, 47:5487-94. 10.1167\/iovs.05-1589","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1038\/eye.2014.311","article-title":"Myopic foveoschisis: a clinical review","volume":"29","author":"Gohil R","year":"2015","unstructured":"Gohil R, Sivaprasad S, Han LT, Mathew R, Kiousis G, Yang Y. Myopic foveoschisis: a clinical review. Eye (Lond). 2015, 29:593-601. 10.1038\/eye.2014.311","journal-title":"Eye (Lond)"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1155\/2015\/847694","article-title":"Central macular thickness in children with myopia, emmetropia, and hyperopia: an optical coherence tomography study","volume":"2015","author":"Yau GS","year":"2015","unstructured":"Yau GS, Lee JW, Woo TT, Wong RL, Wong IY. Central macular thickness in children with myopia, emmetropia, and hyperopia: an optical coherence tomography study. Biomed Res Int. 2015, 2015:847694. 10.1155\/2015\/847694","journal-title":"Biomed Res Int"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.25122\/jml-2023-0251","article-title":"Morphology and thickness of corneal endothelial cells in young Sudanese individuals with myopia","volume":"16","author":"Mutwaly RF","year":"2023","unstructured":"Mutwaly RF, Alrasheed SH, Elmadina AE, Aldakhil S. Morphology and thickness of corneal endothelial cells in young Sudanese individuals with myopia. J Med Life. 2023, 16:1808-12. 10.25122\/jml-2023-0251","journal-title":"J Med Life"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.07-0467","article-title":"Increased-resolution OCT thickness mapping of the human macula: a statistically based registration","volume":"49","author":"Bernardes R","year":"2008","unstructured":"Bernardes R, Santos T, Cunha-Vaz J. Increased-resolution OCT thickness mapping of the human macula: a statistically based registration. Invest Ophthalmol Vis Sci. 2008, 49:2046-52. 10.1167\/iovs.07-0467","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.11-8388","article-title":"Effects of age, sex, and axial length on the three-dimensional profile of normal macular layer structures","volume":"52","author":"Ooto S","year":"2011","unstructured":"Ooto S, Hangai M, Tomidokoro A, et al.. Effects of age, sex, and axial length on the three-dimensional profile of normal macular layer structures. Invest Ophthalmol Vis Sci. 2011, 52:8769-79. 10.1167\/iovs.11-8388","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.1186\/s12886-015-0080-5","article-title":"Effects of myopia on different areas and layers of the macula: a Fourier-domain optical coherence tomography study of a Chinese cohort","volume":"15","author":"Zhao Z","year":"2015","unstructured":"Zhao Z, Zhou X, Jiang C, Sun X. Effects of myopia on different areas and layers of the macula: a Fourier-domain optical coherence tomography study of a Chinese cohort. BMC Ophthalmol. 2015, 15:90. 10.1186\/s12886-015-0080-5","journal-title":"BMC Ophthalmol"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1111\/ceo.13948","article-title":"Associations between optic disc characteristics and macular choroidal microvasculature in young patients with high myopia","volume":"49","author":"Liu X","year":"2021","unstructured":"Liu X, Zhang F, Wang Y, et al.. Associations between optic disc characteristics and macular choroidal microvasculature in young patients with high myopia. Clin Exp Ophthalmol. 2021, 49:560-9. 10.1111\/ceo.13948","journal-title":"Clin Exp Ophthalmol"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.3341\/kjo.2016.30.5.335","article-title":"Influence of myopia on size of optic nerve head and retinal nerve fiber layer thickness measured by spectral domain optical coherence tomography","volume":"30","author":"Bae SH","year":"2016","unstructured":"Bae SH, Kang SH, Feng CS, Park J, Jeong JH, Yi K. Influence of myopia on size of optic nerve head and retinal nerve fiber layer thickness measured by spectral domain optical coherence tomography. Korean J Ophthalmol. 2016, 30:335-43. 10.3341\/kjo.2016.30.5.335","journal-title":"Korean J Ophthalmol"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1111\/j.1475-1313.2010.00788.x","article-title":"Retinal thickness in myopic and non-myopic eyes","volume":"30","author":"Cheng SC","year":"2010","unstructured":"Cheng SC, Lam CS, Yap MK. Retinal thickness in myopic and non-myopic eyes. Ophthalmic Physiol Opt. 2010, 30:776-84. 10.1111\/j.1475-1313.2010.00788.x","journal-title":"Ophthalmic Physiol Opt"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.1038\/sj.eye.6702789","article-title":"Assessment of macular retinal thickness and volume in normal eyes and highly myopic eyes with third-generation optical coherence tomography","volume":"22","author":"Wu PC","year":"2008","unstructured":"Wu PC, Chen YJ, Chen CH, Chen YH, Shin SJ, Yang HJ, Kuo HK. Assessment of macular retinal thickness and volume in normal eyes and highly myopic eyes with third-generation optical coherence tomography. Eye (Lond). 2008, 22:551-5. 10.1038\/sj.eye.6702789","journal-title":"Eye (Lond)"},{"key":"ref15","doi-asserted-by":"publisher","DOI":"10.18502\/jovr.v15i2.6735","article-title":"Myopia and regional variations in retinal thickness in healthy eyes","volume":"15","author":"Zereid FM","year":"2020","unstructured":"Zereid FM, Osuagwu UL. Myopia and regional variations in retinal thickness in healthy eyes. J Ophthalmic Vis Res. 2020, 15:178-86. 10.18502\/jovr.v15i2.6735","journal-title":"J Ophthalmic Vis Res"},{"key":"ref16","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.63.6.20","article-title":"Characteristics of the optic nerve head in myopic eyes using swept-source optical coherence tomography","volume":"63","author":"Cheng D","year":"2022","unstructured":"Cheng D, Ruan K, Wu M, et al.. Characteristics of the optic nerve head in myopic eyes using swept-source optical coherence tomography. Invest Ophthalmol Vis Sci. 2022, 63:20. 10.1167\/iovs.63.6.20","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"ref17","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.09-4737","article-title":"Effect of myopia on the thickness of the retinal nerve fiber layer measured by Cirrus HD optical coherence tomography","volume":"51","author":"Kang SH","year":"2010","unstructured":"Kang SH, Hong SW, Im SK, Lee SH, Ahn MD. Effect of myopia on the thickness of the retinal nerve fiber layer measured by Cirrus HD optical coherence tomography. Invest Ophthalmol Vis Sci. 2010, 51:4075-83. 10.1167\/iovs.09-4737","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"ref18","doi-asserted-by":"publisher","DOI":"10.1016\/j.exer.2024.109824","article-title":"Heterogenous thinning of peripapillary tissues occurs early during high myopia development in juvenile tree shrews","volume":"240","author":"KhalafAllah MT","year":"2024","unstructured":"KhalafAllah MT, Fuchs PA, Nugen F, El Hamdaoui M, Levy AM, Samuels BC, Grytz R. Heterogenous thinning of peripapillary tissues occurs early during high myopia development in juvenile tree shrews. Exp Eye Res. 2024, 240:109824. 10.1016\/j.exer.2024.109824","journal-title":"Exp Eye Res"},{"key":"ref19","doi-asserted-by":"publisher","DOI":"10.1016\/j.preteyeres.2022.101156","article-title":"Myopia: histology, clinical features, and potential implications for the etiology of axial elongation","volume":"96","author":"Jonas JB","year":"2023","unstructured":"Jonas JB, Jonas RA, Bikbov MM, Wang YX, Panda-Jonas S. Myopia: histology, clinical features, and potential implications for the etiology of axial elongation. Prog Retin Eye Res. 2023, 96:101156. 10.1016\/j.preteyeres.2022.101156","journal-title":"Prog Retin Eye Res"},{"key":"ref20","doi-asserted-by":"publisher","DOI":"10.1186\/1746-1596-9-38","article-title":"Spectral- and time-domain optical coherence tomography measurements of macular thickness in young myopic eyes","volume":"9","author":"Liu L","year":"2014","unstructured":"Liu L, Zou J, Jia L, Yang JG, Chen SR. Spectral- and time-domain optical coherence tomography measurements of macular thickness in young myopic eyes. Diagn Pathol. 2014, 9:38. 10.1186\/1746-1596-9-38","journal-title":"Diagn Pathol"},{"key":"ref21","doi-asserted-by":"publisher","DOI":"10.1111\/j.1444-0938.2012.00752.x","article-title":"Macular thickness as determined by optical coherence tomography in relation to degree of myopia, axial length and vitreous chamber depth in Malay subjects","volume":"95","author":"Othman SF","year":"2012","unstructured":"Othman SF, Sharanjeet-Kaur, Manan FA, Zulkarnain AI, Mohamad Z, Ariffin AE. Macular thickness as determined by optical coherence tomography in relation to degree of myopia, axial length and vitreous chamber depth in Malay subjects. Clin Exp Optom. 2012, 95:484-91. 10.1111\/j.1444-0938.2012.00752.x","journal-title":"Clin Exp Optom"},{"key":"ref22","doi-asserted-by":"publisher","DOI":"10.7860\/JCDR\/2015\/11780.5676","article-title":"Foveal and macular thickness evaluation by spectral OCT SLO and its relation with axial length in various degree of myopia","volume":"9","author":"Samuel NE","year":"2015","unstructured":"Samuel NE, Krishnagopal S. Foveal and macular thickness evaluation by spectral OCT SLO and its relation with axial length in various degree of myopia. J Clin Diagn Res. 2015, 9:NC01-4. 10.7860\/JCDR\/2015\/11780.5676","journal-title":"J Clin Diagn Res"},{"key":"ref23","doi-asserted-by":"publisher","DOI":"10.3980\/j.issn.2222-3959.2014.01.23","article-title":"Measurement of retinal thickness in macular region of high myopic eyes using spectral domain OCT","volume":"7","author":"Song AP","year":"2014","unstructured":"Song AP, Wu XY, Wang JR, Liu W, Sun Y, Yu T. Measurement of retinal thickness in macular region of high myopic eyes using spectral domain OCT. Int J Ophthalmol. 2014, 7:122-7. 10.3980\/j.issn.2222-3959.2014.01.23","journal-title":"Int J Ophthalmol"},{"key":"ref24","doi-asserted-by":"publisher","DOI":"10.1007\/s00417-012-1994-8","article-title":"Impact of high myopia on the performance of SD-OCT parameters to detect glaucoma","volume":"250","author":"Shoji T","year":"2012","unstructured":"Shoji T, Nagaoka Y, Sato H, Chihara E. Impact of high myopia on the performance of SD-OCT parameters to detect glaucoma. Graefes Arch Clin Exp Ophthalmol. 2012, 250:1843-9. 10.1007\/s00417-012-1994-8","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"ref25","doi-asserted-by":"publisher","DOI":"10.7860\/JCDR\/2015\/9054.5565","article-title":"Optical coherence tomography assisted retinal nerve fibre layer thickness profile in high myopia","volume":"9","author":"Malakar M","year":"2015","unstructured":"Malakar M, Askari SN, Ashraf H, Waris A, Ahuja A, Asghar A. Optical coherence tomography assisted retinal nerve fibre layer thickness profile in high myopia. J Clin Diagn Res. 2015, 9:NC01-3. 10.7860\/JCDR\/2015\/9054.5565","journal-title":"J Clin Diagn Res"},{"key":"ref26","doi-asserted-by":"publisher","DOI":"10.1111\/j.1444-0938.2012.00749.x","article-title":"Macular thickness and volume of myopic eyes measured using spectral-domain optical coherence tomography","volume":"95","author":"Hwang YH","year":"2012","unstructured":"Hwang YH, Kim YY. Macular thickness and volume of myopic eyes measured using spectral-domain optical coherence tomography. Clin Exp Optom. 2012, 95:492-8. 10.1111\/j.1444-0938.2012.00749.x","journal-title":"Clin Exp Optom"}],"container-title":["Cureus"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cureus.com\/articles\/293506-macula-characteristics-in-young-saudi-male-patients-with-myopia-a-comparative-hospital-based-study","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,9,11]],"date-time":"2024-09-11T11:12:01Z","timestamp":1726053121000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cureus.com\/articles\/293506-macula-characteristics-in-young-saudi-male-patients-with-myopia-a-comparative-hospital-based-study"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,9,11]]},"references-count":26,"URL":"https:\/\/doi.org\/10.7759\/cureus.69168","relation":{},"ISSN":["2168-8184"],"issn-type":[{"value":"2168-8184","type":"print"}],"subject":[],"published":{"date-parts":[[2024,9,11]]}}}