{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,2]],"date-time":"2026-06-02T00:53:18Z","timestamp":1780361598318,"version":"3.54.1"},"reference-count":20,"publisher":"Springer Science and Business Media LLC","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2024,9,11]]},"DOI":"10.7759\/cureus.69237","type":"journal-article","created":{"date-parts":[[2024,9,12]],"date-time":"2024-09-12T06:47:26Z","timestamp":1726123646000},"source":"Crossref","is-referenced-by-count":1,"title":["Comparison Between Conventional and Variable-Angle Locking Compression Plates in Complex Proximal Tibia Fractures"],"prefix":"10.7759","author":[{"given":"Prashant P","family":"Singh","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sunil","family":"Kumar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dinesh","family":"Kumar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pradeep K","family":"Gupta","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sanjeev","family":"Joshi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rajeev","family":"Kumar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Harish","family":"Kumar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gaya","family":"Deen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2018.09.008","article-title":"Epidemiology and incidence of tibia fractures in the Swedish Fracture Register","volume":"49","author":"Wennergren D","year":"2018","unstructured":"Wennergren D, Bergdahl C, Ekelund J, Juto H, Sundfeldt M, M\u00f6ller M. Epidemiology and incidence of tibia fractures in the Swedish Fracture Register. Injury. 2018, 49:2068-74. 10.1016\/j.injury.2018.09.008","journal-title":"Injury"},{"key":"ref2","article-title":"Clinical Epidemiology of Orthopedic Trauma. Fracture of Tibia and Fibula","author":"Zhang YZ","year":"2014","unstructured":"Zhang YZ. Clinical Epidemiology of Orthopedic Trauma. Fracture of Tibia and Fibula. People\u2019s Medical Publishing House, Beijing, pp 289-294, Beijing; 2014."},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-197506000-00025","article-title":"Fractures of tibial plateaus. A review of the literature","author":"Schulak DJ","year":"1975","unstructured":"Schulak DJ, Gunn DR. Fractures of tibial plateaus. A review of the literature. Clin Orthop Relat Res. 1975, 166-77. 10.1097\/00003086-197506000-00025","journal-title":"Clin Orthop Relat Res"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.5435\/00124635-199503000-00004","article-title":"Tibial plateau fracture: evaluation and treatment","volume":"3","author":"Koval KJ","year":"1995","unstructured":"Koval KJ, Helfet DL. Tibial plateau fracture: evaluation and treatment. J Am Acad Orthop Surg. 1995, 3:86-94. 10.5435\/00124635-199503000-00004","journal-title":"J Am Acad Orthop Surg"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1016\/0020-1383(95)00027-7","article-title":"The results of surgical management of displaced tibial plateau fracture in the elderly","volume":"26","author":"Biyani A","year":"1995","unstructured":"Biyani A, Reddy NS, Chaudhary J. The results of surgical management of displaced tibial plateau fracture in the elderly. Injury. 1995, 26:291-7. 10.1016\/0020-1383(95)00027-7","journal-title":"Injury"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2003.09.023","article-title":"General principles for the clinical use of the LCP","volume":"34 Suppl 2","author":"Wagner M","year":"2003","unstructured":"Wagner M. General principles for the clinical use of the LCP. Injury. 2003, 34 Suppl 2:B31-42. 10.1016\/j.injury.2003.09.023","journal-title":"Injury"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2014.10.004","article-title":"Functional outcomes of bicondylar tibial plateau fractures treated with dual buttress plates and risk factors: a case series","volume":"45","author":"Yao Y","year":"2014","unstructured":"Yao Y, Lv H, Zan J, Li J, Zhu N, Jing J. Functional outcomes of bicondylar tibial plateau fractures treated with dual buttress plates and risk factors: a case series. Injury. 2014, 45:1980-4. 10.1016\/j.injury.2014.10.004","journal-title":"Injury"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2003.09.026","article-title":"Guidelines for the clinical application of the LCP","volume":"34 Suppl 2","author":"Gautier E","year":"2003","unstructured":"Gautier E, Sommer C. Guidelines for the clinical application of the LCP. Injury. 2003, 34 Suppl 2:B63-76. 10.1016\/j.injury.2003.09.026","journal-title":"Injury"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2003.09.021","article-title":"Biomechanical testing of the LCP - how can stability in locked internal fixators be controlled?","volume":"34 Suppl 2","author":"Stoffel K","year":"2003","unstructured":"Stoffel K, Dieter U, Stachowiak G, G\u00e4chter A, Kuster MS. Biomechanical testing of the LCP - how can stability in locked internal fixators be controlled?. Injury. 2003, 34 Suppl 2:B11-19. 10.1016\/j.injury.2003.09.021","journal-title":"Injury"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.1007\/s00264-010-1153-y","article-title":"Proximal tibial fractures: early experience using polyaxial locking-plate technology","volume":"35","author":"Nikolaou VS","year":"2011","unstructured":"Nikolaou VS, Tan HB, Haidukewych G, Kanakaris N, Giannoudis PV. Proximal tibial fractures: early experience using polyaxial locking-plate technology. Int Orthop. 2011, 35:1215-21. 10.1007\/s00264-010-1153-y","journal-title":"Int Orthop"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1016\/j.knee.2015.02.002","article-title":"A comparison of lateral fixation versus dual plating for simple bicondylar fractures","volume":"22","author":"Yao Y","year":"2015","unstructured":"Yao Y, Lv H, Zan J, Zhang J, Zhu N, Ning R, Jing J. A comparison of lateral fixation versus dual plating for simple bicondylar fractures. Knee. 2015, 22:225-9. 10.1016\/j.knee.2015.02.002","journal-title":"Knee"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.91B4.20966","article-title":"New trends and techniques in open reduction and internal fixation of fractures of the tibial plateau","volume":"91","author":"Musahl V","year":"2009","unstructured":"Musahl V, Tarkin I, Kobbe P, Tzioupis C, Siska PA, Pape HC. New trends and techniques in open reduction and internal fixation of fractures of the tibial plateau. J Bone Joint Surg Br. 2009, 91:426-33. 10.1302\/0301-620X.91B4.20966","journal-title":"J Bone Joint Surg Br"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.3389\/fsurg.2023.1138274","article-title":"Current concepts review. Management of proximal tibial fractures","volume":"10","author":"Gahr P","year":"2023","unstructured":"Gahr P, Kopf S, Pauly S. Current concepts review. Management of proximal tibial fractures. Front Surg. 2023, 10:1138274. 10.3389\/fsurg.2023.1138274","journal-title":"Front Surg"},{"key":"ref14","article-title":"Management of proximal tibial fractures","author":"Garnavos C","year":"2014","unstructured":"Garnavos C. Management of proximal tibial fractures. European Surgical Orthopaedics and Traumatology. Bentley G (ed): Springer, Heidelberg; 2014."},{"key":"ref15","doi-asserted-by":"publisher","DOI":"10.1302\/2058-5241.1.000031","article-title":"Treatment strategy for tibial plateau fractures: an update","volume":"1","author":"Prat-Fabregat S","year":"2016","unstructured":"Prat-Fabregat S, Camacho-Carrasco P. Treatment strategy for tibial plateau fractures: an update. EFORT Open Rev. 2016, 1:225-32. 10.1302\/2058-5241.1.000031","journal-title":"EFORT Open Rev"},{"key":"ref16","doi-asserted-by":"publisher","DOI":"10.1097\/TA.0b013e3181e17060","article-title":"Stabilization of the posteromedial fragment in bicondylar tibial plateau fractures: a mechanical comparison of locking and nonlocking single and dual plating methods","volume":"69","author":"Yoo BJ","year":"2010","unstructured":"Yoo BJ, Beingessner DM, Barei DP. Stabilization of the posteromedial fragment in bicondylar tibial plateau fractures: a mechanical comparison of locking and nonlocking single and dual plating methods. J Trauma. 2010, 69:148-55. 10.1097\/TA.0b013e3181e17060","journal-title":"J Trauma"},{"key":"ref17","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2020.10.074","article-title":"Newer generation of proximal tibia locking plates demonstrate large variability in their ability to capture the posteromedial fragment in bicondylar tibial plateau fractures","volume":"52","author":"Phillips SA","year":"2021","unstructured":"Phillips SA, Comadoll SM, Hautala GS, et al.. Newer generation of proximal tibia locking plates demonstrate large variability in their ability to capture the posteromedial fragment in bicondylar tibial plateau fractures. Injury. 2021, 52:1534-8. 10.1016\/j.injury.2020.10.074","journal-title":"Injury"},{"key":"ref18","doi-asserted-by":"publisher","DOI":"10.4103\/jodp.jodp_22_21","article-title":"Clinical and radiological evaluation of proximal tibia fracture fixed with variable angle proximal tibial interlocking plate: a prospective observational study","volume":"5","author":"Shekhar S","year":"2022","unstructured":"Shekhar S, Pranjal A. Clinical and radiological evaluation of proximal tibia fracture fixed with variable angle proximal tibial interlocking plate: a prospective observational study. J Orthop Dis Traumatol. 2022, 5:8-13. 10.4103\/jodp.jodp_22_21","journal-title":"J Orthop Dis Traumatol"},{"key":"ref19","doi-asserted-by":"publisher","DOI":"10.1186\/s12891-021-04158-z","article-title":"Outcome after polyaxial locking plate osteosynthesis in proximal tibia fractures: a prospective clinical trial","volume":"22","author":"V\u00f6lk D","year":"2021","unstructured":"V\u00f6lk D, Neumaier M, Einhellig H, Biberthaler P, Hanschen M. Outcome after polyaxial locking plate osteosynthesis in proximal tibia fractures: a prospective clinical trial. BMC Musculoskelet Disord. 2021, 22:286. 10.1186\/s12891-021-04158-z","journal-title":"BMC Musculoskelet Disord"},{"key":"ref20","doi-asserted-by":"publisher","DOI":"10.1016\/j.cjtee.2016.08.002","article-title":"Complications in the management of closed high-energy proximal tibial plateau fractures","volume":"19","author":"Khatri K","year":"2016","unstructured":"Khatri K, Sharma V, Goyal D, Farooque K. Complications in the management of closed high-energy proximal tibial plateau fractures. Chin J Traumatol. 2016, 19:342-7. 10.1016\/j.cjtee.2016.08.002","journal-title":"Chin J Traumatol"}],"container-title":["Cureus"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cureus.com\/articles\/291306-comparison-between-conventional-and-variable-angle-locking-compression-plates-in-complex-proximal-tibia-fractures","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,9,12]],"date-time":"2024-09-12T06:47:28Z","timestamp":1726123648000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cureus.com\/articles\/291306-comparison-between-conventional-and-variable-angle-locking-compression-plates-in-complex-proximal-tibia-fractures"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,9,11]]},"references-count":20,"URL":"https:\/\/doi.org\/10.7759\/cureus.69237","relation":{},"ISSN":["2168-8184"],"issn-type":[{"value":"2168-8184","type":"print"}],"subject":[],"published":{"date-parts":[[2024,9,11]]}}}