{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,29]],"date-time":"2026-09-29T21:09:49Z","timestamp":1790716189416,"version":"4.1.0"},"reference-count":15,"publisher":"Springer Science and Business Media LLC","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2024,10,3]]},"DOI":"10.7759\/cureus.70789","type":"journal-article","created":{"date-parts":[[2024,10,3]],"date-time":"2024-10-03T21:20:14Z","timestamp":1727990414000},"source":"Crossref","is-referenced-by-count":16,"title":["Compact Arterial Monitoring Device Use in Resuscitative Endovascular Balloon Occlusion of the Aorta (REBOA): A Simple Validation Study in Swine"],"prefix":"10.7759","author":[{"given":"Glen","family":"Lussier","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andrew J","family":"Evans","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Isaac","family":"Houston","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andrew","family":"Wilsnack","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christopher M","family":"Russo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert","family":"Vietor","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peter","family":"Bedocs","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1097\/TA.0b013e3182755dcc","article-title":"Death on the battlefield (2001-2011): implications for the future of combat casualty care","volume":"73","author":"Eastridge BJ","year":"2012","unstructured":"Eastridge BJ, Mabry RL, Seguin P, et al.. Death on the battlefield (2001-2011): implications for the future of combat casualty care. J Trauma Acute Care Surg. 2012, 73:S431-7. 10.1097\/TA.0b013e3182755dcc","journal-title":"J Trauma Acute Care Surg"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1097\/TA.0000000000001476","article-title":"Field and en route resuscitative endovascular occlusion of the aorta: a feasible military reality?","volume":"83","author":"Reva VA","year":"2017","unstructured":"Reva VA, H\u00f6rer TM, Makhnovskiy AI, Sokhranov MV, Samokhvalov IM, DuBose JJ. Field and en route resuscitative endovascular occlusion of the aorta: a feasible military reality?. J Trauma Acute Care Surg. 2017, 83:S170-6. 10.1097\/TA.0000000000001476","journal-title":"J Trauma Acute Care Surg"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.55460\/9H3H-5GPS","article-title":"A modern case series of resuscitative endovascular balloon occlusion of the aorta (REBOA) in an out-of-hospital, combat casualty care setting","volume":"17","author":"Manley JD","year":"2017","unstructured":"Manley JD, Mitchell BJ, DuBose JJ, Rasmussen TE. A modern case series of resuscitative endovascular balloon occlusion of the aorta (REBOA) in an out-of-hospital, combat casualty care setting. J Spec Oper Med. 2017, 17:1-8. 10.55460\/9H3H-5GPS","journal-title":"J Spec Oper Med"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1097\/TA.0000000000001966","article-title":"Recent advances in austere combat surgery: use of aortic balloon occlusion as well as blood challenges by special operations medical forces in recent combat operations","volume":"85","author":"Northern DM","year":"2018","unstructured":"Northern DM, Manley JD, Lyon R, et al.. Recent advances in austere combat surgery: use of aortic balloon occlusion as well as blood challenges by special operations medical forces in recent combat operations. J Trauma Acute Care Surg. 2018, 85:S98-S103. 10.1097\/TA.0000000000001966","journal-title":"J Trauma Acute Care Surg"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1186\/s13017-018-0213-2","article-title":"Three cases of resuscitative endovascular balloon occlusion of the aorta (REBOA) in austere pre-hospital environment-technical and methodological aspects","volume":"13","author":"de Schoutheete JC","year":"2018","unstructured":"de Schoutheete JC, Fourneau I, Waroquier F, et al.. Three cases of resuscitative endovascular balloon occlusion of the aorta (REBOA) in austere pre-hospital environment-technical and methodological aspects. World J Emerg Surg. 2018, 13:54. 10.1186\/s13017-018-0213-2","journal-title":"World J Emerg Surg"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1093\/milmed\/usab473","article-title":"Ranger O low titer (ROLO): whole blood transfusion for forward deployed units","volume":"10","author":"Song KH","year":"2021","unstructured":"Song KH, Winebrenner HM, Able TE, Bowen CB, Dunn NA, Shevchik JD. Ranger O low titer (ROLO): whole blood transfusion for forward deployed units. Mil Med. 2021, 10:21. 10.1093\/milmed\/usab473","journal-title":"Mil Med"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1016\/j.resuscitation.2016.06.029","article-title":"Resuscitative endovascular balloon occlusion of the aorta (REBOA) in the pre-hospital setting: an additional resuscitation option for uncontrolled catastrophic haemorrhage","volume":"107","author":"Sadek S","year":"2016","unstructured":"Sadek S, Lockey DJ, Lendrum RA, Perkins Z, Price J, Davies GE. Resuscitative endovascular balloon occlusion of the aorta (REBOA) in the pre-hospital setting: an additional resuscitation option for uncontrolled catastrophic haemorrhage. Resuscitation. 2016, 107:135-8. 10.1016\/j.resuscitation.2016.06.029","journal-title":"Resuscitation"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1016\/j.resuscitation.2018.12.018","article-title":"Pre-hospital resuscitative endovascular balloon occlusion of the aorta (REBOA) for exsanguinating pelvic haemorrhage","volume":"135","author":"Lendrum R","year":"2019","unstructured":"Lendrum R, Perkins Z, Chana M, et al.. Pre-hospital resuscitative endovascular balloon occlusion of the aorta (REBOA) for exsanguinating pelvic haemorrhage. Resuscitation. 2019, 135:6-13. 10.1016\/j.resuscitation.2018.12.018","journal-title":"Resuscitation"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.1097\/SHK.0000000000000085","article-title":"Use of resuscitative endovascular balloon occlusion of the aorta in a highly lethal model of noncompressible torso hemorrhage","volume":"41","author":"Morrison JJ","year":"2014","unstructured":"Morrison JJ, Ross JD, Houston R 4th, Watson JD, Sokol KK, Rasmussen TE. Use of resuscitative endovascular balloon occlusion of the aorta in a highly lethal model of noncompressible torso hemorrhage. Shock. 2014, 41:130-7. 10.1097\/SHK.0000000000000085","journal-title":"Shock"},{"key":"ref10","unstructured":"Centurion Compass for Thoracentesis Device. (2024). Accessed. June 02, 2024: https:\/\/www.medline.com\/product\/Compass-for-Thoracentesis-Device-by-Centurion\/Thoracentesis-Trays\/Z05-PF166765."},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1002\/emp2.12791","article-title":"Emergency department initiated resuscitative endovascular balloon occlusion of the aorta (REBOA) for out-of-hospital cardiac arrest is feasible and associated with improvements in end-tidal carbon dioxide","volume":"3","author":"Daley J","year":"2022","unstructured":"Daley J, Buckley R, Kisken KC, et al.. Emergency department initiated resuscitative endovascular balloon occlusion of the aorta (REBOA) for out-of-hospital cardiac arrest is feasible and associated with improvements in end-tidal carbon dioxide. J Am Coll Emerg Physicians Open. 2022, 3:e12791. 10.1002\/emp2.12791","journal-title":"J Am Coll Emerg Physicians Open"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1016\/j.amj.2020.05.015","article-title":"Accuracy and reliability of a disposable vascular pressure device for arterial pressure monitoring in critical care transport","volume":"39","author":"Schmid KM","year":"2020","unstructured":"Schmid KM, Lauria MJ, Braude DA, Crandall CS, Marinaro JL. Accuracy and reliability of a disposable vascular pressure device for arterial pressure monitoring in critical care transport. Air Med J. 2020, 39:389-92. 10.1016\/j.amj.2020.05.015","journal-title":"Air Med J"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-021-03502-6","article-title":"Use of a disposable vascular pressure device to guide balloon inflation of resuscitative endovascular balloon occlusion of the aorta: a bench study","volume":"11","author":"Levis A","year":"2021","unstructured":"Levis A, Egli N, Jenni H, Hautz WE, Daley JI, Haenggi M. Use of a disposable vascular pressure device to guide balloon inflation of resuscitative endovascular balloon occlusion of the aorta: a bench study. Sci Rep. 2021, 11:24055. 10.1038\/s41598-021-03502-6","journal-title":"Sci Rep"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.1097\/TA.0000000000003467","article-title":"Resuscitative endovascular balloon occlusion of the aorta management guided by a novel handheld pressure transducer","volume":"92","author":"Holtestaul T","year":"2022","unstructured":"Holtestaul T, Jones I, Conner J, et al.. Resuscitative endovascular balloon occlusion of the aorta management guided by a novel handheld pressure transducer. J Trauma Acute Care Surg. 2022, 92:729-34. 10.1097\/TA.0000000000003467","journal-title":"J Trauma Acute Care Surg"},{"key":"ref15","doi-asserted-by":"publisher","DOI":"10.1007\/s00068-022-02121-8","article-title":"Validation of a miniaturized handheld arterial pressure monitor for guiding full and partial REBOA use during resuscitation","volume":"49","author":"Benham DA","year":"2023","unstructured":"Benham DA, Carr MJ, Wessels L, et al.. Validation of a miniaturized handheld arterial pressure monitor for guiding full and partial REBOA use during resuscitation. Eur J Trauma Emerg Surg. 2023, 49:795-801. 10.1007\/s00068-022-02121-8","journal-title":"Eur J Trauma Emerg Surg"}],"container-title":["Cureus"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cureus.com\/articles\/294198-compact-arterial-monitoring-device-use-in-resuscitative-endovascular-balloon-occlusion-of-the-aorta-reboa-a-simple-validation-study-in-swine","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,10,3]],"date-time":"2024-10-03T21:20:17Z","timestamp":1727990417000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cureus.com\/articles\/294198-compact-arterial-monitoring-device-use-in-resuscitative-endovascular-balloon-occlusion-of-the-aorta-reboa-a-simple-validation-study-in-swine"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,10,3]]},"references-count":15,"URL":"https:\/\/doi.org\/10.7759\/cureus.70789","relation":{},"ISSN":["2168-8184"],"issn-type":[{"value":"2168-8184","type":"print"}],"subject":[],"published":{"date-parts":[[2024,10,3]]}}}