{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,10,19]],"date-time":"2024-10-19T04:21:00Z","timestamp":1729311660003,"version":"3.27.0"},"reference-count":9,"publisher":"Springer Science and Business Media LLC","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2024,10,18]]},"DOI":"10.7759\/cureus.71803","type":"journal-article","created":{"date-parts":[[2024,10,19]],"date-time":"2024-10-19T00:46:21Z","timestamp":1729298781000},"source":"Crossref","is-referenced-by-count":0,"title":["Unique Presentation of Refracture of the Distal Radius With Volar Plate Bending in an Elderly Patient"],"prefix":"10.7759","author":[{"given":"Mamoun","family":"Belkebir Mrani","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Pierre","family":"Pirlot","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Serge","family":"Ayong","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","reference":[{"key":"ref1","article-title":"Association of open reduction and internal fixation with volar locking plate for distal radius fractures with patient-reported outcomes in older adults: a network meta-analysis","volume":"16","author":"Jayaram M","year":"2023","unstructured":"Jayaram M, Wood SM, Kane RL, et al.. Association of open reduction and internal fixation with volar locking plate for distal radius fractures with patient-reported outcomes in older adults: a network meta-analysis. JAMA Network Open [Internet]. 2023, 16:2318715.","journal-title":"JAMA Network Open [Internet]"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1530\/EOR-23-0188","article-title":"Complications after volar plate synthesis for distal radius fractures","volume":"9","author":"Pacchiarini L","year":"2024","unstructured":"Pacchiarini L, Massimo Oldrini L, Feltri P, Lucchina S, Filardo G, Candrian C. Complications after volar plate synthesis for distal radius fractures. EFORT Open Rev. 2024, 9:567-80. 10.1530\/EOR-23-0188","journal-title":"EFORT Open Rev"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1515\/BMT.2009.018","article-title":"[Biomechanical study of four palmar locking plates and one non-locking palmar plate for distal radius fractures: stiffness and load to failure tests in a cadaver model]","volume":"54","author":"Rudig L","year":"2009","unstructured":"Rudig L, Mehling I, Klitscher D, Mehler D, Prommersberger KJ, Rommens PM, M\u00fcller LP. [Biomechanical study of four palmar locking plates and one non-locking palmar plate for distal radius fractures: stiffness and load to failure tests in a cadaver model]. Biomed Tech (Berl). 2009, 54:150-8. 10.1515\/BMT.2009.018","journal-title":"Biomed Tech (Berl)"},{"key":"ref4","doi-asserted-by":"crossref","DOI":"10.1016\/j.otsr.2018.05.002","article-title":"Biomechanical comparison between stainless steel, titanium and carbon-fiber reinforced polyetheretherketone volar locking plates for distal radius fractures","volume":"104","author":"Mugnai R","year":"2018","unstructured":"Mugnai R, Tarallo L, Capra F, Catani F. Biomechanical comparison between stainless steel, titanium and carbon-fiber reinforced polyetheretherketone volar locking plates for distal radius fractures. Ortho Traum Surg Res. 2018, 104:877-82.","journal-title":"Ortho Traum Surg Res"},{"key":"ref5","unstructured":"Annals of Clinical Case Reports. Fixation failure of a volar wrist plate following a fall from a standing height. (2024). Accessed: October 18, 2024: https:\/\/www.anncaserep.com\/open-access\/divfixation-failure-of-a-volar-wrist-plate-following-a-6221.pdf."},{"key":"ref6","article-title":"Successful closed reduction of refractured wrist with a bent volar distal radius plate","volume":"78","author":"Geurts GF","year":"2012","unstructured":"Geurts GF, Van Riet RP, Verstreken F. Successful closed reduction of refractured wrist with a bent volar distal radius plate. Acta Orthop Belg. 2012, 78:126-8.","journal-title":"Acta Orthop Belg"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1007\/s11552-007-9074-y","article-title":"Biomechanical comparison of different volar fracture fixation plates for distal radius fractures","volume":"3","author":"Sobky K","year":"2008","unstructured":"Sobky K, Baldini T, Thomas K, Bach J, Williams A, Wolf JM. Biomechanical comparison of different volar fracture fixation plates for distal radius fractures. Hand (N Y). 2008, 3:96-101. 10.1007\/s11552-007-9074-y","journal-title":"Hand (N Y)"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1007\/s00068-013-0283-5","article-title":"Indications for implant removal after fracture healing: a review of the literature","volume":"39","author":"Vos DI","year":"2013","unstructured":"Vos DI, Verhofstad MH. Indications for implant removal after fracture healing: a review of the literature. Eur J Trauma Emerg Surg. 2013, 39:327-37. 10.1007\/s00068-013-0283-5","journal-title":"Eur J Trauma Emerg Surg"},{"key":"ref9","doi-asserted-by":"crossref","DOI":"10.1016\/j.injury.2017.10.010","article-title":"A systematic review of volar locking plate removal after distal radius fracture","volume":"48","author":"Yamamoto M","year":"2017","unstructured":"Yamamoto M, Fujihara Y, Fujihara N, et al.. A systematic review of volar locking plate removal after distal radius fracture. Injury. 2017, 48:2650-6.","journal-title":"Injury"}],"container-title":["Cureus"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cureus.com\/articles\/308841-unique-presentation-of-refracture-of-the-distal-radius-with-volar-plate-bending-in-an-elderly-patient","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,10,19]],"date-time":"2024-10-19T00:46:24Z","timestamp":1729298784000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cureus.com\/articles\/308841-unique-presentation-of-refracture-of-the-distal-radius-with-volar-plate-bending-in-an-elderly-patient"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,10,18]]},"references-count":9,"URL":"https:\/\/doi.org\/10.7759\/cureus.71803","relation":{},"ISSN":["2168-8184"],"issn-type":[{"value":"2168-8184","type":"print"}],"subject":[],"published":{"date-parts":[[2024,10,18]]}}}