{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,10,23]],"date-time":"2024-10-23T04:17:42Z","timestamp":1729657062784,"version":"3.28.0"},"reference-count":13,"publisher":"Springer Science and Business Media LLC","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2024,10,22]]},"DOI":"10.7759\/cureus.72095","type":"journal-article","created":{"date-parts":[[2024,10,22]],"date-time":"2024-10-22T08:57:07Z","timestamp":1729587427000},"source":"Crossref","is-referenced-by-count":0,"title":["Keep Right: Inadvertent Placement of a Temporary Pacing Lead in the Left Ventricle"],"prefix":"10.7759","author":[{"given":"Dinesh Abhijeeth","family":"Shanker","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Howard","family":"Briggs","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Abraham","family":"Chacko","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1016\/j.echo.2007.03.003","article-title":"A stroke of bad luck: left ventricular pacemaker malposition","volume":"20","author":"Reising S","year":"2007","unstructured":"Reising S, Safford R, Castello R, Bosworth V, Freeman W, Kusumoto F. A stroke of bad luck: left ventricular pacemaker malposition. J Am Soc Echocardiogr. 2007, 20:1316.e1-3. 10.1016\/j.echo.2007.03.003","journal-title":"J Am Soc Echocardiogr"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1993.tb01814.x","article-title":"Malposition of transvenous pacing lead in the left ventricle","volume":"16","author":"Ghani M","year":"1993","unstructured":"Ghani M, Thakur RK, Boughner D, Morillo CA, Yee R, Klein GJ. Malposition of transvenous pacing lead in the left ventricle. Pacing Clin Electrophysiol. 1993, 16:1800-7. 10.1111\/j.1540-8159.1993.tb01814.x","journal-title":"Pacing Clin Electrophysiol"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1093\/europace\/euv270","article-title":"Incidence, predictors, and outcome of inadvertent malposition of transvenous pacing or defibrillation lead in the left heart","volume":"18","author":"Ohlow MA","year":"2016","unstructured":"Ohlow MA, Roos M, Lauer B, Von Korn H, Geller JC. Incidence, predictors, and outcome of inadvertent malposition of transvenous pacing or defibrillation lead in the left heart. Europace. 2016, 18:1049-54. 10.1093\/europace\/euv270","journal-title":"Europace"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.2214\/ajr.162.2.8310911","article-title":"Malposition of transvenous pacing lead in the left ventricle: radiographic findings","volume":"162","author":"Bauersfeld UK","year":"1994","unstructured":"Bauersfeld UK, Thakur RK, Ghani M, Yee R, Klein GJ. Malposition of transvenous pacing lead in the left ventricle: radiographic findings. AJR Am J Roentgenol. 1994, 162:290-2. 10.2214\/ajr.162.2.8310911","journal-title":"AJR Am J Roentgenol"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.3390\/jcdd9100362","article-title":"Inadvertent lead malposition in the left heart during implantation of cardiac electric devices: a systematic review","volume":"9","author":"Spighi L","year":"2022","unstructured":"Spighi L, Notaristefano F, Piraccini S, et al.. Inadvertent lead malposition in the left heart during implantation of cardiac electric devices: a systematic review. J Cardiovasc Dev Dis. 2022, 9:10.3390\/jcdd9100362","journal-title":"J Cardiovasc Dev Dis"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1111\/echo.14938","article-title":"Echocardiographic diagnosis of permanent pacemaker lead malposition in the left ventricle: a case study","volume":"37","author":"Luke P","year":"2020","unstructured":"Luke P, Shepherd E, Irvine T, Duncan R. Echocardiographic diagnosis of permanent pacemaker lead malposition in the left ventricle: a case study. Echocardiography. 2020, 37:2163-7. 10.1111\/echo.14938","journal-title":"Echocardiography"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.19102\/icrm.2020.110207","article-title":"Causes of failure to capture in pacemakers and implantable cardioverter-defibrillators","volume":"11","author":"Sabbagh E","year":"2020","unstructured":"Sabbagh E, Abdelfattah T, Karim MM, Farah A, Grubb B, Karim S. Causes of failure to capture in pacemakers and implantable cardioverter-defibrillators. J Innov Card Rhythm Manag. 2020, 11:4013-7. 10.19102\/icrm.2020.110207","journal-title":"J Innov Card Rhythm Manag"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1016\/j.ipej.2017.11.005","article-title":"Right bundle branch block pattern after uncomplicated right ventricular outflow tract pacing in a patient with a left sided superior vena cava and corrected tetralogy of Fallot","volume":"18","author":"Gupta A","year":"2018","unstructured":"Gupta A, Parakh N, Juneja R. Right bundle branch block pattern after uncomplicated right ventricular outflow tract pacing in a patient with a left sided superior vena cava and corrected tetralogy of Fallot. Indian Pacing Electrophysiol J. 2018, 18:39-41. 10.1016\/j.ipej.2017.11.005","journal-title":"Indian Pacing Electrophysiol J"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.4236\/wjcd.2023.1311065","article-title":"Inadvertent lead malposition in the left ventricle during permanent ventricular pacing: a case report","volume":"13","author":"Dia K","year":"2023","unstructured":"Dia K, Mboup W, Ndao S, et al.. Inadvertent lead malposition in the left ventricle during permanent ventricular pacing: a case report. World J Cardiovasc Dis. 2023, 13:756-63. 10.4236\/wjcd.2023.1311065","journal-title":"World J Cardiovasc Dis"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.1016\/j.jaccas.2021.09.008","article-title":"Inadvertent lead malposition: prevention is better than cure","volume":"3","author":"Foley N","year":"2021","unstructured":"Foley N, Sukmawati I, Harding SA. Inadvertent lead malposition: prevention is better than cure. JACC Case Rep. 2021, 3:1753-5. 10.1016\/j.jaccas.2021.09.008","journal-title":"JACC Case Rep"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.2000.tb00858.x","article-title":"Diagnosis and management of inadvertently placed pacing and ICD leads in the left ventricle: a multicenter experience and review of the literature","volume":"23","author":"Van Gelder BM","year":"2000","unstructured":"Van Gelder BM, Bracke FA, Oto A, et al.. Diagnosis and management of inadvertently placed pacing and ICD leads in the left ventricle: a multicenter experience and review of the literature. Pacing Clin Electrophysiol. 2000, 23:877-83. 10.1111\/j.1540-8159.2000.tb00858.x","journal-title":"Pacing Clin Electrophysiol"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1186\/s12959-021-00259-w","article-title":"Warfarin versus direct oral anticoagulants for treating left ventricular thrombus: a systematic review and meta-analysis","volume":"19","author":"Dalia T","year":"2021","unstructured":"Dalia T, Lahan S, Ranka S, Goyal A, Zoubek S, Gupta K, Shah Z. Warfarin versus direct oral anticoagulants for treating left ventricular thrombus: a systematic review and meta-analysis. Thromb J. 2021, 19:7. 10.1186\/s12959-021-00259-w","journal-title":"Thromb J"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.7759\/cureus.49277","article-title":"Unintentional implantation of a permanent pacemaker lead across a patent foramen ovale leading to left ventricular pacing","volume":"15","author":"Khan IA","year":"2023","unstructured":"Khan IA, Mazhar S. Unintentional implantation of a permanent pacemaker lead across a patent foramen ovale leading to left ventricular pacing. Cureus. 2023, 15:e49277. 10.7759\/cureus.49277","journal-title":"Cureus"}],"container-title":["Cureus"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cureus.com\/articles\/306785-keep-right-inadvertent-placement-of-a-temporary-pacing-lead-in-the-left-ventricle","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,10,22]],"date-time":"2024-10-22T08:57:09Z","timestamp":1729587429000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cureus.com\/articles\/306785-keep-right-inadvertent-placement-of-a-temporary-pacing-lead-in-the-left-ventricle"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,10,22]]},"references-count":13,"URL":"https:\/\/doi.org\/10.7759\/cureus.72095","relation":{},"ISSN":["2168-8184"],"issn-type":[{"value":"2168-8184","type":"print"}],"subject":[],"published":{"date-parts":[[2024,10,22]]}}}