{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,17]],"date-time":"2026-10-17T20:45:42Z","timestamp":1792269942446,"version":"4.4.0"},"reference-count":20,"publisher":"Springer Science and Business Media LLC","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2024,10,23]]},"DOI":"10.7759\/cureus.72207","type":"journal-article","created":{"date-parts":[[2024,10,23]],"date-time":"2024-10-23T15:01:03Z","timestamp":1729695663000},"source":"Crossref","is-referenced-by-count":4,"title":["The Effect of Intraoral Thermal Changes on the Mechanical Behavior of Nickel-Titanium Wires: An In-Vitro Study"],"prefix":"10.7759","author":[{"given":"Odayy S","family":"Al-Horini","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mariam Marwan","family":"Masaes","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Feras","family":"Baba","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mohammad Y","family":"Hajeer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Soghyia Talib Ibrahim","family":"Almulla","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mudar Mohammad","family":"Mousa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1111\/ocr.12048","article-title":"A systematic review and meta-analysis of experimental clinical evidence on initial aligning archwires and archwire sequences","volume":"17","author":"Papageorgiou SN","year":"2014","unstructured":"Papageorgiou SN, Konstantinidis I, Papadopoulou K, J\u00e4ger A, Bourauel C. A systematic review and meta-analysis of experimental clinical evidence on initial aligning archwires and archwire sequences. Orthod Craniofac Res. 2014, 17:197-215. 10.1111\/ocr.12048","journal-title":"Orthod Craniofac Res"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1043\/0003-3219(1997)067<0197:AROCAT>2.3.CO;2","article-title":"A review of contemporary archwires: their properties and characteristics","volume":"67","author":"Kusy RP","year":"1997","unstructured":"Kusy RP. A review of contemporary archwires: their properties and characteristics. Angle Orthod. 1997, 67:197-207. 10.1043\/0003-3219(1997)067&lt;0197:AROCAT&gt;2.3.CO;2","journal-title":"Angle Orthod"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1016\/0889-5406(86)90021-1","article-title":"The super-elastic property of the Japanese NiTi alloy wire for use in orthodontics","volume":"90","author":"Miura F","year":"1986","unstructured":"Miura F, Mogi M, Ohura Y, Hamanaka H. The super-elastic property of the Japanese NiTi alloy wire for use in orthodontics. Am J Orthod Dentofacial Orthop. 1986, 90:1-10. 10.1016\/0889-5406(86)90021-1","journal-title":"Am J Orthod Dentofacial Orthop"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9416(85)90083-1","article-title":"Chinese NiTi wire--a new orthodontic alloy","volume":"87","author":"Burstone CJ","year":"1985","unstructured":"Burstone CJ, Qin B, Morton JY. Chinese NiTi wire--a new orthodontic alloy. Am J Orthod. 1985, 87:445-52. 10.1016\/0002-9416(85)90083-1","journal-title":"Am J Orthod"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.2319\/032511-213.1","article-title":"Load deflection characteristics and force level of nickel titanium initial archwires","volume":"82","author":"Lombardo L","year":"2011","unstructured":"Lombardo L, Marafioti M, Stefanoni F, Mollica F, Siciliani G. Load deflection characteristics and force level of nickel titanium initial archwires. Angle Orthod. 2011, 82:507-21. 10.2319\/032511-213.1","journal-title":"Angle Orthod"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1016\/0889-5406(91)70013-M","article-title":"Bending properties of superelastic and nonsuperelastic nickel-titanium orthodontic wires","volume":"99","author":"Khier SE","year":"1991","unstructured":"Khier SE, Brantley WA, Fournelle RA. Bending properties of superelastic and nonsuperelastic nickel-titanium orthodontic wires. Am J Orthod Dentofacial Orthop. 1991, 99:310-8. 10.1016\/0889-5406(91)70013-M","journal-title":"Am J Orthod Dentofacial Orthop"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1093\/ejo\/21.3.249","article-title":"Intra-oral temperature variation over 24 hours","volume":"21","author":"Moore RJ","year":"1999","unstructured":"Moore RJ, Watts JT, Hood JA, Burritt DJ. Intra-oral temperature variation over 24 hours. Eur J Orthod. 1999, 21:249-61. 10.1093\/ejo\/21.3.249","journal-title":"Eur J Orthod"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1016\/0022-3913(92)90239-7","article-title":"Temperature extremes produced orally by hot and cold liquids","volume":"67","author":"Palmer DS","year":"1992","unstructured":"Palmer DS, Barco MT, Billy EJ. Temperature extremes produced orally by hot and cold liquids. J Prosthet Dent. 1992, 67:325-7. 10.1016\/0022-3913(92)90239-7","journal-title":"J Prosthet Dent"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2842.2005.01509.x","article-title":"Intra-oral temperatures during function","volume":"32","author":"Barclay CW","year":"2005","unstructured":"Barclay CW, Spence D, Laird WR. Intra-oral temperatures during function. J Oral Rehabil. 2005, 32:886-94. 10.1111\/j.1365-2842.2005.01509.x","journal-title":"J Oral Rehabil"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.7759\/cureus.27206","article-title":"Evaluating the elemental composition, transformation behavior, crystalline structure, and mechanical properties of three 0.016-inch by 0.022-inch nickel-titanium archwires: an in vitro study","volume":"14","author":"Al-Horini O","year":"2022","unstructured":"Al-Horini O, Hajeer MY, Baba F. Evaluating the elemental composition, transformation behavior, crystalline structure, and mechanical properties of three 0.016-inch by 0.022-inch nickel-titanium archwires: an in vitro study. Cureus. 2022, 14:e27206. 10.7759\/cureus.27206","journal-title":"Cureus"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1016\/j.msea.2003.10.327","article-title":"Structural and functional fatigue of NiTi shape memory alloys","volume":"378","author":"Eggeler G","year":"2004","unstructured":"Eggeler G, Hornbogen E, Yawny A, Heckmann A, Wagner M. Structural and functional fatigue of NiTi shape memory alloys. Mater Sci Eng A. 2004, 378:24-33. 10.1016\/j.msea.2003.10.327","journal-title":"Mater Sci Eng A"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1016\/j.proeng.2015.12.645","article-title":"Mean strain effects on the fatigue behavior of superelastic Nitinol alloys: an experimental investigation","volume":"133","author":"Mahtabi MJ","year":"2015","unstructured":"Mahtabi MJ, Shamsaei N, Rutherford B. Mean strain effects on the fatigue behavior of superelastic Nitinol alloys: an experimental investigation. Proc Eng. 2015, 133:646-54. 10.1016\/j.proeng.2015.12.645","journal-title":"Proc Eng"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1016\/s0109-5641(01)00025-2","article-title":"Mechanical behavior at different temperatures and stresses for superelastic nickel-titanium orthodontic wires having different transformation temperatures","volume":"18","author":"Iijima M","year":"2002","unstructured":"Iijima M, Ohno H, Kawashima I, Endo K, Mizoguchi I. Mechanical behavior at different temperatures and stresses for superelastic nickel-titanium orthodontic wires having different transformation temperatures. Dent Mater. 2002, 18:88-93. 10.1016\/s0109-5641(01)00025-2","journal-title":"Dent Mater"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.1093\/ejo\/cji079","article-title":"How does temperature influence the properties of rectangular nickel-titanium wires?","volume":"28","author":"Sakima MT","year":"2006","unstructured":"Sakima MT, Dalstra M, Melsen B. How does temperature influence the properties of rectangular nickel-titanium wires?. Eur J Orthod. 2006, 28:282-91. 10.1093\/ejo\/cji079","journal-title":"Eur J Orthod"},{"key":"ref15","doi-asserted-by":"publisher","DOI":"10.7759\/cureus.31952","article-title":"The effect of elastic and metallic ligation methods on the unloading forces for three different types of nickel-titanium archwires inserted into metallic brackets: an in-vitro study","volume":"14","author":"Al-Horini OS","year":"2022","unstructured":"Al-Horini OS, Baba F, Hajeer MY, Mousa MM. The effect of elastic and metallic ligation methods on the unloading forces for three different types of nickel-titanium archwires inserted into metallic brackets: an in-vitro study. Cureus. 2022, 14:e31952. 10.7759\/cureus.31952","journal-title":"Cureus"},{"key":"ref16","unstructured":"ISO. Dentistry \u2014 Wires for use in orthodontics. (2014). Accessed: November 12, 2022: https:\/\/www.iso.org\/standard\/62223.html."},{"key":"ref17","doi-asserted-by":"publisher","DOI":"10.1007\/s10973-015-4441-3","article-title":"DSC and three-point bending test for the study of the thermo-mechanical history of NiTi and NiTi-based orthodontic archwires","volume":"120","author":"Nespoli A","year":"2015","unstructured":"Nespoli A, Villa E, Bergo L, Rizzacasa A, Passaretti F. DSC and three-point bending test for the study of the thermo-mechanical history of NiTi and NiTi-based orthodontic archwires. J Therm Anal Calorim. 2015, 120:1129-38. 10.1007\/s10973-015-4441-3","journal-title":"J Therm Anal Calorim"},{"key":"ref18","doi-asserted-by":"publisher","DOI":"10.4012\/dmj.18.403","article-title":"Relationship between Af temperature and load changes in Ni-Ti orthodontic wire under different thermomechanical conditions","volume":"18","author":"Kawashima I","year":"1999","unstructured":"Kawashima I, Ohno H, Sachdeva R. Relationship between Af temperature and load changes in Ni-Ti orthodontic wire under different thermomechanical conditions. Dent Mater J. 1999, 18:403-12. 10.4012\/dmj.18.403","journal-title":"Dent Mater J"},{"key":"ref19","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejwf.2020.08.005","article-title":"Evolution, clinical applications, and prospects of nickel-titanium alloys for orthodontic purposes","volume":"9","author":"Brantley WA","year":"2020","unstructured":"Brantley WA. Evolution, clinical applications, and prospects of nickel-titanium alloys for orthodontic purposes. J World Fed Orthod. 2020, 9:S19-26. 10.1016\/j.ejwf.2020.08.005","journal-title":"J World Fed Orthod"},{"key":"ref20","doi-asserted-by":"publisher","DOI":"10.1007\/s00056-003-0062-8","article-title":"Transformation behavior, chemical composition, surface topography and bending properties of five selected 0.016\" x 0.022\" NiTi archwires","volume":"64","author":"Fischer-Brandies H","year":"2003","unstructured":"Fischer-Brandies H, Es-Souni M, Kock N, Raetzke K, Bock O. Transformation behavior, chemical composition, surface topography and bending properties of five selected 0.016\" x 0.022\" NiTi archwires. J Orofac Orthop. 2003, 64:88-99. 10.1007\/s00056-003-0062-8","journal-title":"J Orofac Orthop"}],"container-title":["Cureus"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cureus.com\/articles\/309423-the-effect-of-intraoral-thermal-changes-on-the-mechanical-behavior-of-nickel-titanium-wires-an-in-vitro-study","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,10,23]],"date-time":"2024-10-23T15:01:07Z","timestamp":1729695667000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cureus.com\/articles\/309423-the-effect-of-intraoral-thermal-changes-on-the-mechanical-behavior-of-nickel-titanium-wires-an-in-vitro-study"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,10,23]]},"references-count":20,"URL":"https:\/\/doi.org\/10.7759\/cureus.72207","relation":{},"ISSN":["2168-8184"],"issn-type":[{"value":"2168-8184","type":"print"}],"subject":[],"published":{"date-parts":[[2024,10,23]]}}}