{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,26]],"date-time":"2026-09-26T01:52:49Z","timestamp":1790387569723,"version":"4.1.0"},"reference-count":21,"publisher":"Springer Science and Business Media LLC","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2024,10,23]]},"DOI":"10.7759\/cureus.72226","type":"journal-article","created":{"date-parts":[[2024,10,23]],"date-time":"2024-10-23T20:02:43Z","timestamp":1729713763000},"source":"Crossref","is-referenced-by-count":4,"title":["Evaluation of the Conventional Acid-Etching System and the Self-Etching Primer in Bonding Metallic Orthodontic Brackets: An In-Vitro and In-Vivo Study"],"prefix":"10.7759","author":[{"given":"Mohammed Hussin","family":"Alomar","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Naji","family":"Massoud","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mohammad Y","family":"Hajeer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hani","family":"Kharma","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Doaa Hussain","family":"Jomah","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.7860\/JCDR\/2016\/18842.9031","article-title":"Comparison of self-etch primers with conventional acid etching system on orthodontic brackets","volume":"10","author":"Zope A","year":"2016","unstructured":"Zope A, Zope-Khalekar Y, Chitko SS, et al.. Comparison of self-etch primers with conventional acid etching system on orthodontic brackets. J Clin Diagn Res. 2016, 10:ZC19-22. 10.7860\/JCDR\/2016\/18842.9031","journal-title":"J Clin Diagn Res"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.18502\/fid.v16i4.2083","article-title":"Shear bond strength of brackets bonded with self-etching primers compared to conventional acid-etch technique: A randomized clinical trial","volume":"16","author":"Farhadian N","year":"2019","unstructured":"Farhadian N, Miresmaeili A, Zandi VS. Shear bond strength of brackets bonded with self-etching primers compared to conventional acid-etch technique: A randomized clinical trial. Front Dent. 2019, 16:248-55. 10.18502\/fid.v16i4.2083","journal-title":"Front Dent"},{"key":"ref3","article-title":"Phosphoric acid incorporated with acidulated phosphate fluoride gel etchant effects on bracket bonding","volume":"75","author":"Kim MJ","year":"2005","unstructured":"Kim MJ, Lim BS, Chang WG, Lee YK, Rhee SH, Yang HC. Phosphoric acid incorporated with acidulated phosphate fluoride gel etchant effects on bracket bonding. Angle Orthod. 2005, 75:678-84.","journal-title":"Angle Orthod"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1016\/s0889-5406(98)70205-7","article-title":"Effect of an acidic primer on shear bond strength of orthodontic brackets","volume":"114","author":"Bishara SE","year":"1998","unstructured":"Bishara SE, Gordan VV, VonWald L, Olson ME. Effect of an acidic primer on shear bond strength of orthodontic brackets. Am J Orthod Dentofacial Orthop. 1998, 114:10.1016\/s0889-5406(98)70205-7","journal-title":"Am J Orthod Dentofacial Orthop"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1093\/ejo\/cjac050","article-title":"Clinical bracket failure rates between different bonding techniques: A systematic review and meta-analysis","volume":"45","author":"Dud\u00e1s C","year":"2023","unstructured":"Dud\u00e1s C, Czumbel LM, Kiss S, Gede N, Hegyi P, M\u00e1rtha K, Varga G. Clinical bracket failure rates between different bonding techniques: A systematic review and meta-analysis. Eur J Orthod. 2023, 45:175-85. 10.1093\/ejo\/cjac050","journal-title":"Eur J Orthod"},{"key":"ref6","article-title":"Comparison of shear bond strength of three self-etching adhesives: An in-vitro study","volume":"7","author":"Yadala C","year":"2015","unstructured":"Yadala C, Gaddam R, Arya S, Baburamreddy KV, Raju VR, Varma PK. Comparison of shear bond strength of three self-etching adhesives: An in-vitro study. J Int Oral Health. 2015, 7:53-7.","journal-title":"J Int Oral Health"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1016\/j.ortho.2016.03.005","article-title":"Comparison of the efficacy of a conventional primer and a self-etching primer","volume":"14","author":"Ousehal L","year":"2016","unstructured":"Ousehal L, El Aouame A, Rachdy Z, Benkiran G. Comparison of the efficacy of a conventional primer and a self-etching primer. Int Orthod. 2016, 14:195-205. 10.1016\/j.ortho.2016.03.005","journal-title":"Int Orthod"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.4103\/jpbs.jpbs_412_21","article-title":"Comparative evaluation of shear bond strength of brackets bonded with self etch primer\/adhesive and conventional etch\/primer and adhesive system","volume":"13","author":"Bhattacharjee D","year":"2021","unstructured":"Bhattacharjee D, Sharma K, Sahu R, Neha K, Kumari A, Rai A. Comparative evaluation of shear bond strength of brackets bonded with self etch primer\/adhesive and conventional etch\/primer and adhesive system. J Pharm Bioallied Sci. 2021, 13:S1168-73. 10.4103\/jpbs.jpbs_412_21","journal-title":"J Pharm Bioallied Sci"},{"key":"ref9","article-title":"A comparison of shear bond strength and debonding characteristics of conventional, moisture-insensitive, and self-etching primers in vitro","volume":"74","author":"Rajagopal R","year":"2004","unstructured":"Rajagopal R, Padmanabhan S, Gnanamani J. A comparison of shear bond strength and debonding characteristics of conventional, moisture-insensitive, and self-etching primers in vitro. Angle Orthod. 2004, 74:264-8.","journal-title":"Angle Orthod"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.1093\/ejo\/25.4.411","article-title":"Laboratory evaluation of a self-etching primer for orthodontic bonding","volume":"25","author":"Aljubouri YD","year":"2003","unstructured":"Aljubouri YD, Millett DT, Gilmour WH. Laboratory evaluation of a self-etching primer for orthodontic bonding. Eur J Orthod. 2003, 25:411-5. 10.1093\/ejo\/25.4.411","journal-title":"Eur J Orthod"},{"key":"ref11","article-title":"Comparison of bonding time and shear bond strength between a conventional and a new integrated bonding system","volume":"75","author":"Bishara SE","year":"2005","unstructured":"Bishara SE, Oonsombat C, Soliman MM, Warren JJ, Laffoon JF, Ajlouni R. Comparison of bonding time and shear bond strength between a conventional and a new integrated bonding system. Angle Orthod. 2005, 75:237-42.","journal-title":"Angle Orthod"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1016\/j.ortho.2021.09.001","article-title":"Comparison of the failure rate, bonding time and ARI score of two orthodontic bonding systems: Self-Etch Primer and Conventional Etching Primer: A systematic review and meta-analysis","volume":"19","author":"Namdari M","year":"2021","unstructured":"Namdari M, Amdjadi P, Bayat A, Seifi M, Alzwghaibi A. Comparison of the failure rate, bonding time and ARI score of two orthodontic bonding systems: Self-Etch Primer and Conventional Etching Primer: A systematic review and meta-analysis. Int Orthod. 2021, 19:566-79. 10.1016\/j.ortho.2021.09.001","journal-title":"Int Orthod"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1111\/ocr.12602","article-title":"Comparison of shear bond strength of orthodontic brackets bonded to human teeth with and without fluorotic enamel: A\u00a0systematic review and meta-analysis of experimental in vitro studies","volume":"26","author":"Alvarez D","year":"2023","unstructured":"Alvarez D, Barmak AB, Rossouw PE, Michelogiannakis D. Comparison of shear bond strength of orthodontic brackets bonded to human teeth with and without fluorotic enamel: A\u00a0systematic review and meta-analysis of experimental in vitro studies. Orthod Craniofac Res. 2023, 26:141-50. 10.1111\/ocr.12602","journal-title":"Orthod Craniofac Res"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.2319\/022307-90.1","article-title":"Rebonding of orthodontic brackets. Part I, a laboratory and clinical study","volume":"78","author":"Montasser MA","year":"2008","unstructured":"Montasser MA, Drummond JL, Evans CA. Rebonding of orthodontic brackets. Part I, a laboratory and clinical study. Angle Orthod. 2008, 78:531-6. 10.2319\/022307-90.1","journal-title":"Angle Orthod"},{"key":"ref15","article-title":"Effect of self-etching primers on bond strength\u2014are they reliable?","volume":"10","author":"Buyukyilmaz T","year":"2003","unstructured":"Buyukyilmaz T, Usumez S, Karaman AI. Effect of self-etching primers on bond strength\u2014are they reliable?. Angle Orthod. 2003, 10:64-70.","journal-title":"Angle Orthod"},{"key":"ref16","article-title":"Clinical evaluation of bond failure rates with a new self-etching primer","volume":"36","author":"Asgari S","year":"2002","unstructured":"Asgari S, Salas A, English J, Powers J. Clinical evaluation of bond failure rates with a new self-etching primer. J Clin Orthod. 2002, 36:687-9.","journal-title":"J Clin Orthod"},{"key":"ref17","article-title":"Comparison of shear bond strength of new self-etching primer with conventional self-etching primers: An in-vitro study","volume":"7","author":"Sorake A","year":"2015","unstructured":"Sorake A, Rai R, Hegde G, Suneja R, Kumar N, Skaria J. Comparison of shear bond strength of new self-etching primer with conventional self-etching primers: An in-vitro study. J Int Oral Health. 2015, 7:17-21.","journal-title":"J Int Oral Health"},{"key":"ref18","doi-asserted-by":"publisher","DOI":"10.2319\/112507-552.1","article-title":"12-month self-ligating bracket failure rate with a self-etching primer","volume":"78","author":"Elekdag-Turk S","year":"2008","unstructured":"Elekdag-Turk S, Cakmak F, Isci D, Turk T. 12-month self-ligating bracket failure rate with a self-etching primer. Angle Orthod. 2008, 78:1095-100. 10.2319\/112507-552.1","journal-title":"Angle Orthod"},{"key":"ref19","article-title":"Effect of a self-etching primer on shear bond strength of adhesive precoated brackets in vivo","volume":"76","author":"Cal-Neto JP","year":"2006","unstructured":"Cal-Neto JP, Miguel JA, Zanella E. Effect of a self-etching primer on shear bond strength of adhesive precoated brackets in vivo. Angle Orthod. 2006, 76:127-31.","journal-title":"Angle Orthod"},{"key":"ref20","doi-asserted-by":"publisher","DOI":"10.4103\/ccd.ccd_647_17","article-title":"Microphotographic assessment of enamel surface using self-etching primer and conventional phosphoric acid: An in vitro study","volume":"9","author":"Gandhi G","year":"2018","unstructured":"Gandhi G, Kalra JP, Goyal A, Sharma A. Microphotographic assessment of enamel surface using self-etching primer and conventional phosphoric acid: An in vitro study. Contemp Clin Dent. 2018, 9:15-9. 10.4103\/ccd.ccd_647_17","journal-title":"Contemp Clin Dent"},{"key":"ref21","doi-asserted-by":"publisher","DOI":"10.1093\/ortho\/27.2.181","article-title":"Investigation of a hydrophilic primer for orthodontic bonding: An in vitro study","volume":"27","author":"Littlewood SJ","year":"2000","unstructured":"Littlewood SJ, Mitchell L, Greenwood DC, Bubb NL, Wood DJ. Investigation of a hydrophilic primer for orthodontic bonding: An in vitro study. J Orthod. 2000, 27:181-6. 10.1093\/ortho\/27.2.181","journal-title":"J Orthod"}],"container-title":["Cureus"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cureus.com\/articles\/309107-evaluation-of-the-conventional-acid-etching-system-and-the-self-etching-primer-in-bonding-metallic-orthodontic-brackets-an-in-vitro-and-in-vivo-study","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,10,23]],"date-time":"2024-10-23T20:02:47Z","timestamp":1729713767000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cureus.com\/articles\/309107-evaluation-of-the-conventional-acid-etching-system-and-the-self-etching-primer-in-bonding-metallic-orthodontic-brackets-an-in-vitro-and-in-vivo-study"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,10,23]]},"references-count":21,"URL":"https:\/\/doi.org\/10.7759\/cureus.72226","relation":{},"ISSN":["2168-8184"],"issn-type":[{"value":"2168-8184","type":"print"}],"subject":[],"published":{"date-parts":[[2024,10,23]]}}}