{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,10,24]],"date-time":"2024-10-24T04:25:28Z","timestamp":1729743928001,"version":"3.28.0"},"reference-count":12,"publisher":"Springer Science and Business Media LLC","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2024,10,23]]},"DOI":"10.7759\/cureus.72228","type":"journal-article","created":{"date-parts":[[2024,10,23]],"date-time":"2024-10-23T20:50:35Z","timestamp":1729716635000},"source":"Crossref","is-referenced-by-count":0,"title":["A Rare Case of Shunt Malfunction Due to the Needle Guard Coming Off During Ventriculoperitoneal Shunt Surgery"],"prefix":"10.7759","author":[{"given":"Hajime","family":"Ono","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tomohiro","family":"Kaji","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hiroyuki","family":"Morishima","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Goro","family":"Nagashima","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1007\/s00381-021-05125-8","article-title":"Mechanical complications of cerebrospinal fluid shunt. Differences between adult and pediatric populations: myths or reality?","volume":"37","author":"Coll G","year":"2021","unstructured":"Coll G, Abed Rabbo F, de Schlichting E, et al.. Mechanical complications of cerebrospinal fluid shunt. Differences between adult and pediatric populations: myths or reality?. Childs Nerv Syst. 2021, 37:2215-21. 10.1007\/s00381-021-05125-8","journal-title":"Childs Nerv Syst"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.3109\/02688699209023790","article-title":"Mechanical complications of the reservoirs and flushing devices in ventricular shunt systems","volume":"6","author":"Martinez-Lage JF","year":"1992","unstructured":"Martinez-Lage JF, Poza M, Esteban JA. Mechanical complications of the reservoirs and flushing devices in ventricular shunt systems. Br J Neurosurg. 1992, 6:321-5. 10.3109\/02688699209023790","journal-title":"Br J Neurosurg"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.7759\/cureus.35002","article-title":"Ventriculoperitoneal shunt surgery for hydrocephalus: one of the common neurosurgical procedures and its related problems","volume":"15","author":"Javeed F","year":"2023","unstructured":"Javeed F, Mohan A, Wara UU, Rehman L, Khan M. Ventriculoperitoneal shunt surgery for hydrocephalus: one of the common neurosurgical procedures and its related problems. Cureus. 2023, 15:e35002. 10.7759\/cureus.35002","journal-title":"Cureus"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.2176\/nmc.st.2020-0292","article-title":"Guidelines for management of idiopathic normal pressure hydrocephalus (third edition): endorsed by the Japanese Society of Normal Pressure Hydrocephalus","volume":"61","author":"Nakajima M","year":"2021","unstructured":"Nakajima M, Yamada S, Miyajima M, et al.. Guidelines for management of idiopathic normal pressure hydrocephalus (third edition): endorsed by the Japanese Society of Normal Pressure Hydrocephalus. Neurol Med Chir (Tokyo). 2021, 61:63-97. 10.2176\/nmc.st.2020-0292","journal-title":"Neurol Med Chir (Tokyo)"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.3171\/2012.10.PEDS12239","article-title":"Hydrodynamic properties of the Certas hydrocephalus shunt","volume":"11","author":"Czosnyka Z","year":"2013","unstructured":"Czosnyka Z, Pickard JD, Czosnyka M. Hydrodynamic properties of the Certas hydrocephalus shunt. J Neurosurg Pediatr. 2013, 11:198-204. 10.3171\/2012.10.PEDS12239","journal-title":"J Neurosurg Pediatr"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1186\/2045-8118-9-12","article-title":"Hydrodynamics of the Certas\u2122 programmable valve for the treatment of hydrocephalus","volume":"9","author":"Eklund A","year":"2012","unstructured":"Eklund A, Koskinen LO, Williams MA, Luciano MG, Dombrowski SM, Malm J. Hydrodynamics of the Certas\u2122 programmable valve for the treatment of hydrocephalus. Fluids Barriers CNS. 2012, 9:12. 10.1186\/2045-8118-9-12","journal-title":"Fluids Barriers CNS"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1227\/neu.0000000000002225","article-title":"Placebo-controlled effectiveness of idiopathic normal pressure hydrocephalus shunting: a randomized pilot trial","volume":"92","author":"Luciano M","year":"2023","unstructured":"Luciano M, Holubkov R, Williams MA, et al.. Placebo-controlled effectiveness of idiopathic normal pressure hydrocephalus shunting: a randomized pilot trial. Neurosurgery. 2023, 92:481-9. 10.1227\/neu.0000000000002225","journal-title":"Neurosurgery"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1007\/s11940-019-0604-z","article-title":"Current update on treatment strategies for idiopathic normal pressure hydrocephalus","volume":"21","author":"Isaacs AM","year":"2019","unstructured":"Isaacs AM, Williams MA, Hamilton MG. Current update on treatment strategies for idiopathic normal pressure hydrocephalus. Curr Treat Options Neurol. 2019, 21:65. 10.1007\/s11940-019-0604-z","journal-title":"Curr Treat Options Neurol"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.3171\/2012.7.FOCUS12179","article-title":"Patterns in neurosurgical adverse events: cerebrospinal fluid shunt surgery","volume":"33","author":"Wong JM","year":"2012","unstructured":"Wong JM, Ziewacz JE, Ho AL, et al.. Patterns in neurosurgical adverse events: cerebrospinal fluid shunt surgery. Neurosurg Focus. 2012, 33:E13. 10.3171\/2012.7.FOCUS12179","journal-title":"Neurosurg Focus"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.4103\/0028-3886.332261","article-title":"Techniques and nuances in ventriculoperitoneal shunt surgery","volume":"69","author":"Pillai SV","year":"2021","unstructured":"Pillai SV. Techniques and nuances in ventriculoperitoneal shunt surgery. Neurol India. 2021, 69:S471-5. 10.4103\/0028-3886.332261","journal-title":"Neurol India"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.3171\/2016.6.FOCUS15540","article-title":"An improved reservoir for the flushing test to diagnose shunt insufficiency","volume":"41","author":"Schlosser HG","year":"2016","unstructured":"Schlosser HG, Crawack HJ, Miethke C, Knitter T, Zeiner A, Sprung C. An improved reservoir for the flushing test to diagnose shunt insufficiency. Neurosurg Focus. 2016, 41:E14. 10.3171\/2016.6.FOCUS15540","journal-title":"Neurosurg Focus"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.3171\/2014.2.PEDS13436","article-title":"Disruption of silicone valve housing in a Codman Hakim Precision valve with integrated Siphonguard","volume":"13","author":"Woerdeman PA","year":"2014","unstructured":"Woerdeman PA, Cochrane DD. Disruption of silicone valve housing in a Codman Hakim Precision valve with integrated Siphonguard. J Neurosurg Pediatr. 2014, 13:532-5. 10.3171\/2014.2.PEDS13436","journal-title":"J Neurosurg Pediatr"}],"container-title":["Cureus"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cureus.com\/articles\/309797-a-rare-case-of-shunt-malfunction-due-to-the-needle-guard-coming-off-during-ventriculoperitoneal-shunt-surgery","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,10,23]],"date-time":"2024-10-23T20:50:37Z","timestamp":1729716637000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cureus.com\/articles\/309797-a-rare-case-of-shunt-malfunction-due-to-the-needle-guard-coming-off-during-ventriculoperitoneal-shunt-surgery"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,10,23]]},"references-count":12,"URL":"https:\/\/doi.org\/10.7759\/cureus.72228","relation":{},"ISSN":["2168-8184"],"issn-type":[{"value":"2168-8184","type":"print"}],"subject":[],"published":{"date-parts":[[2024,10,23]]}}}