{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T06:01:30Z","timestamp":1787032890060,"version":"build-2736575974"},"reference-count":20,"publisher":"Springer Science and Business Media LLC","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2024,11,11]]},"DOI":"10.7759\/cureus.73478","type":"journal-article","created":{"date-parts":[[2024,11,11]],"date-time":"2024-11-11T17:03:19Z","timestamp":1731344599000},"source":"Crossref","is-referenced-by-count":1,"title":["C1 Lateral Mass Screw Insertion Caudally From the C2 Nerve Root to Avoid Craniocervical Fusion in a Patient With Atlantoaxial Subluxation Associated With Ponticulus Posticus: A Case Report"],"prefix":"10.7759","author":[{"given":"Satoshi","family":"Hattori","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Keiji","family":"Wada","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Futoshi","family":"Watanabe","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Satoru","family":"Matsutani","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.3389\/fsurg.2022.834551","article-title":"Research progress of ponticulus posticus: a narrative literature review","volume":"9","author":"Xu X","year":"2022","unstructured":"Xu X, Zhu Y, Ding X, Yin M, Mo W, Ma J. Research progress of ponticulus posticus: a narrative literature review. Front Surg. 2022, 9:834551. 10.3389\/fsurg.2022.834551","journal-title":"Front Surg"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1016\/j.wneu.2018.02.100","article-title":"The ponticulus posticus as risk factor for screw insertion into the first cervical lateral mass","volume":"113","author":"Arslan D","year":"2018","unstructured":"Arslan D, Ozer MA, Govsa F, K\u0131t\u0131s O. The ponticulus posticus as risk factor for screw insertion into the first cervical lateral mass. World Neurosurg. 2018, 113:e579-85. 10.1016\/j.wneu.2018.02.100","journal-title":"World Neurosurg"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1016\/j.wneu.2018.07.038","article-title":"Arcuate foramen: anatomy, embryology, nomenclature, pathology, and surgical considerations","volume":"118","author":"Ahn J","year":"2018","unstructured":"Ahn J, Duran M, Syldort S, et al.. Arcuate foramen: anatomy, embryology, nomenclature, pathology, and surgical considerations. World Neurosurg. 2018, 118:197-202. 10.1016\/j.wneu.2018.07.038","journal-title":"World Neurosurg"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1016\/j.wneu.2013.09.014","article-title":"The prevalence of the ponticulus posticus (arcuate foramen) and its importance in the Goel-Harms procedure: meta-analysis and review of the literature","volume":"82","author":"Elliott RE","year":"2014","unstructured":"Elliott RE, Tanweer O. The prevalence of the ponticulus posticus (arcuate foramen) and its importance in the Goel-Harms procedure: meta-analysis and review of the literature. World Neurosurg. 2014, 82:e335-43. 10.1016\/j.wneu.2013.09.014","journal-title":"World Neurosurg"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.7860\/JCDR\/2013\/6795.3847","article-title":"Ponticulus posticus on the posterior arch of atlas, prevalence analysis in symptomatic and asymptomatic patients of gulbarga population","volume":"7","author":"Chitroda PK","year":"2013","unstructured":"Chitroda PK, Katti G, Baba IA, Najmudin M, Ghali SR, Kalmath B, G V. Ponticulus posticus on the posterior arch of atlas, prevalence analysis in symptomatic and asymptomatic patients of gulbarga population. J Clin Diagn Res. 2013, 7:3044-7. 10.7860\/JCDR\/2013\/6795.3847","journal-title":"J Clin Diagn Res"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1007\/s00586-016-4589-y","article-title":"The feasibility of inserting a C1 pedicle screw in patients with ponticulus posticus: a retrospective analysis of eleven patients","volume":"26","author":"Zhang XL","year":"2017","unstructured":"Zhang XL, Huang DG, Wang XD, Zhu JW, Li YB, He BR, Hao DJ. The feasibility of inserting a C1 pedicle screw in patients with ponticulus posticus: a retrospective analysis of eleven patients. Eur Spine J. 2017, 26:1058-63. 10.1007\/s00586-016-4589-y","journal-title":"Eur Spine J"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-200511000-00017","article-title":"The ponticulus posticus: implications for screw insertion into the first cervical lateral mass","volume":"87","author":"Young JO","year":"2005","unstructured":"Young JO, Young PH, Ackermann MJ, et al.. The ponticulus posticus: implications for screw insertion into the first cervical lateral mass. J Bone Joint Surg Am. 2005, 87:2495-8. 10.2106\/00004623-200511000-00017","journal-title":"J Bone Joint Surg Am"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1016\/j.spinee.2015.06.040","article-title":"Ponticulus posticus","volume":"15","author":"Huang DG","year":"2015","unstructured":"Huang DG, Hao DJ, Fang XY, Zhang XL, He BR, Liu TJ. Ponticulus posticus. Spine J. 2015, 15:e17-9. 10.1016\/j.spinee.2015.06.040","journal-title":"Spine J"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.1007\/BF01400872","article-title":"Plate and screw fixation for atlanto-axial subluxation","volume":"129","author":"Goel A","year":"1994","unstructured":"Goel A, Laheri V. Plate and screw fixation for atlanto-axial subluxation. Acta Neurochir (Wien). 1994, 129:47-53. 10.1007\/BF01400872","journal-title":"Acta Neurochir (Wien)"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.1097\/00007632-200111150-00014","article-title":"Posterior C1-C2 fusion with polyaxial screw and rod fixation","volume":"26","author":"Harms J","year":"2001","unstructured":"Harms J, Melcher RP. Posterior C1-C2 fusion with polyaxial screw and rod fixation. Spine (Phila Pa 1976). 2001, 26:2467-71. 10.1097\/00007632-200111150-00014","journal-title":"Spine (Phila Pa 1976)"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1097\/01.BRS.0000058719.48596.CC","article-title":"Morphometric evaluation of screw fixation in atlas via posterior arch and lateral mass","volume":"28","author":"Tan M","year":"2003","unstructured":"Tan M, Wang H, Wang Y, et al.. Morphometric evaluation of screw fixation in atlas via posterior arch and lateral mass. Spine (Phila Pa 1976). 2003, 28:888-95. 10.1097\/01.BRS.0000058719.48596.CC","journal-title":"Spine (Phila Pa 1976)"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1016\/j.jocn.2012.01.045","article-title":"Modified C1 lateral mass screw insertion using a high entry point to avoid postoperative occipital neuralgia","volume":"20","author":"Lee SH","year":"2013","unstructured":"Lee SH, Kim ES, Eoh W. Modified C1 lateral mass screw insertion using a high entry point to avoid postoperative occipital neuralgia. J Clin Neurosci. 2013, 20:162-7. 10.1016\/j.jocn.2012.01.045","journal-title":"J Clin Neurosci"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1016\/j.clineuro.2017.04.001","article-title":"Ponticulus posticus: morphometric analysis and Its anatomical Implications for occipito-cervical fusion","volume":"157","author":"Song MS","year":"2017","unstructured":"Song MS, Lee HJ, Kim JT, Kim JH, Hong JT. Ponticulus posticus: morphometric analysis and Its anatomical Implications for occipito-cervical fusion. Clin Neurol Neurosurg. 2017, 157:76-81. 10.1016\/j.clineuro.2017.04.001","journal-title":"Clin Neurol Neurosurg"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.1097\/01.brs.0000245902.93084.12","article-title":"The feasibility of inserting atlas lateral mass screws via the posterior arch","volume":"31","author":"Lee MJ","year":"2006","unstructured":"Lee MJ, Cassinelli E, Riew KD. The feasibility of inserting atlas lateral mass screws via the posterior arch. Spine (Phila Pa 1976). 2006, 31:2798-801. 10.1097\/01.brs.0000245902.93084.12","journal-title":"Spine (Phila Pa 1976)"},{"key":"ref15","doi-asserted-by":"publisher","DOI":"10.1016\/j.jos.2016.10.008","article-title":"C1 lateral mass screw insertion caudally from C2 nerve root - an alternate method for insertion of C1 screws: a technical note and preliminary clinical results","volume":"22","author":"Wada K","year":"2017","unstructured":"Wada K, Tamaki R, Yui M, Numaguchi D, Murata Y. C1 lateral mass screw insertion caudally from C2 nerve root - an alternate method for insertion of C1 screws: a technical note and preliminary clinical results. J Orthop Sci. 2017, 22:213-7. 10.1016\/j.jos.2016.10.008","journal-title":"J Orthop Sci"},{"key":"ref16","doi-asserted-by":"publisher","DOI":"10.1177\/028418516400200403","article-title":"A variation of the atlas: roentgenologic incidence of a bridge over the groove of the atlas for the vertebral artery","volume":"2","author":"Romanus T","year":"1964","unstructured":"Romanus T, Tovi A. A variation of the atlas: roentgenologic incidence of a bridge over the groove of the atlas for the vertebral artery. Acta Radiol Diagn (Stockh). 1964, 2:289-97. 10.1177\/028418516400200403","journal-title":"Acta Radiol Diagn (Stockh)"},{"key":"ref17","doi-asserted-by":"publisher","DOI":"10.3171\/2021.8.SPINE21695","article-title":"Feasibility of lateral mass screw insertion in patients with the risky triad of C1: evaluation of the over-the-arch technique","volume":"36","author":"Lee HR","year":"2022","unstructured":"Lee HR, Lee DH, Cho JH, Hwang ES, Seok SY, Park S, Lee CS. Feasibility of lateral mass screw insertion in patients with the risky triad of C1: evaluation of the over-the-arch technique. J Neurosurg Spine. 2022, 36:822-9. 10.3171\/2021.8.SPINE21695","journal-title":"J Neurosurg Spine"},{"key":"ref18","doi-asserted-by":"publisher","DOI":"10.1097\/01.brs.0000259833.02179.c0","article-title":"C1 anatomy and dimensions relative to lateral mass screw placement","volume":"32","author":"Christensen DM","year":"2007","unstructured":"Christensen DM, Eastlack RK, Lynch JJ, Yaszemski MJ, Currier BL. C1 anatomy and dimensions relative to lateral mass screw placement. Spine (Phila Pa 1976). 2007, 32:844-8. 10.1097\/01.brs.0000259833.02179.c0","journal-title":"Spine (Phila Pa 1976)"},{"key":"ref19","doi-asserted-by":"publisher","DOI":"10.1016\/j.jocn.2017.04.041","article-title":"C1 lateral mass screw insertion from the caudal-dorsal to the cranial-ventral direction as an alternate method for C1 fixation: a quantitative anatomical and morphometric evaluation","volume":"42","author":"Senoglu M","year":"2017","unstructured":"Senoglu M, Karadag A, Kinali B, Bozkurt B, Icke C, Halacoglu Savran D, Middlebrooks EH. C1 lateral mass screw insertion from the caudal-dorsal to the cranial-ventral direction as an alternate method for C1 fixation: a quantitative anatomical and morphometric evaluation. J Clin Neurosci. 2017, 42:176-81. 10.1016\/j.jocn.2017.04.041","journal-title":"J Clin Neurosci"},{"key":"ref20","doi-asserted-by":"publisher","DOI":"10.1016\/j.wneu.2020.07.182","article-title":"Prevalence of high-riding vertebral artery: a meta-analysis of the anatomical variant affecting choice of craniocervical fusion method and its outcome","volume":"143","author":"Klepinowski T","year":"2020","unstructured":"Klepinowski T, Pala B, Cembik J, Sagan L. Prevalence of high-riding vertebral artery: a meta-analysis of the anatomical variant affecting choice of craniocervical fusion method and its outcome. World Neurosurg. 2020, 143:e474-81. 10.1016\/j.wneu.2020.07.182","journal-title":"World Neurosurg"}],"container-title":["Cureus"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cureus.com\/articles\/309465-c1-lateral-mass-screw-insertion-caudally-from-the-c2-nerve-root-to-avoid-craniocervical-fusion-in-a-patient-with-atlantoaxial-subluxation-associated-with-ponticulus-posticus-a-case-report","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,11,11]],"date-time":"2024-11-11T17:03:21Z","timestamp":1731344601000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cureus.com\/articles\/309465-c1-lateral-mass-screw-insertion-caudally-from-the-c2-nerve-root-to-avoid-craniocervical-fusion-in-a-patient-with-atlantoaxial-subluxation-associated-with-ponticulus-posticus-a-case-report"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,11,11]]},"references-count":20,"URL":"https:\/\/doi.org\/10.7759\/cureus.73478","relation":{},"ISSN":["2168-8184"],"issn-type":[{"value":"2168-8184","type":"print"}],"subject":[],"published":{"date-parts":[[2024,11,11]]}}}