{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,27]],"date-time":"2026-06-27T08:04:20Z","timestamp":1782547460963,"version":"3.54.5"},"reference-count":15,"publisher":"Springer Science and Business Media LLC","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2024,11,13]]},"DOI":"10.7759\/cureus.73638","type":"journal-article","created":{"date-parts":[[2024,11,14]],"date-time":"2024-11-14T05:16:42Z","timestamp":1731561402000},"source":"Crossref","is-referenced-by-count":2,"title":["A Misplaced S2 Alar-Iliac Screw Causing L5 Spinal Nerve Injury: A Report of a Rare Case"],"prefix":"10.7759","author":[{"given":"Toru","family":"Funayama","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yohei","family":"Yanagisawa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yosuke","family":"Ogata","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shun","family":"Okuwaki","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Masaki","family":"Tatsumura","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1097\/BRS.0b013e318194128c","article-title":"Low profile pelvic fixation: anatomic parameters for sacral alar-iliac fixation versus traditional iliac fixation","volume":"34","author":"Chang TL","year":"2009","unstructured":"Chang TL, Sponseller PD, Kebaish KM, Fishman EK. Low profile pelvic fixation: anatomic parameters for sacral alar-iliac fixation versus traditional iliac fixation. Spine (Phila Pa 1976). 2009, 34:436-40. 10.1097\/BRS.0b013e318194128c","journal-title":"Spine (Phila Pa 1976)"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1097\/BRS.0b013e3181a4e3e4","article-title":"An anatomic study of the S2 iliac technique for lumbopelvic screw placement","volume":"34","author":"O'Brien JR","year":"2009","unstructured":"O'Brien JR, Yu WD, Bhatnagar R, Sponseller P, Kebaish KM. An anatomic study of the S2 iliac technique for lumbopelvic screw placement. Spine (Phila Pa 1976). 2009, 34:E439-42. 10.1097\/BRS.0b013e3181a4e3e4","journal-title":"Spine (Phila Pa 1976)"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1007\/s43390-022-00528-2","article-title":"S2 alar-iliac screw versus traditional iliac screw for spinopelvic fixation: a systematic review of comparative biomechanical studies","volume":"10","author":"Hirase T","year":"2022","unstructured":"Hirase T, Shin C, Ling J, Phelps B, Haghshenas V, Saifi C, Hanson DS. S2 alar-iliac screw versus traditional iliac screw for spinopelvic fixation: a systematic review of comparative biomechanical studies. Spine Deform. 2022, 10:1279-88. 10.1007\/s43390-022-00528-2","journal-title":"Spine Deform"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.3171\/2018.7.SPINE18710","article-title":"Iliac screw versus S2 alar-iliac screw fixation in adults: a meta-analysis","volume":"30","author":"De la Garza Ramos R","year":"2019","unstructured":"De la Garza Ramos R, Nakhla J, Sciubba DM, Yassari R. Iliac screw versus S2 alar-iliac screw fixation in adults: a meta-analysis. J Neurosurg Spine. 2019, 30:253-8. 10.3171\/2018.7.SPINE18710","journal-title":"J Neurosurg Spine"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1007\/s43390-024-00834-x","article-title":"S2 alar-iliac screws are superior to traditional iliac screws for spinopelvic fixation in adult spinal deformity: a systematic review and meta-analysis","volume":"12","author":"Rahmani R","year":"2024","unstructured":"Rahmani R, Stegelmann SD, Andreshak T. S2 alar-iliac screws are superior to traditional iliac screws for spinopelvic fixation in adult spinal deformity: a systematic review and meta-analysis. Spine Deform. 2024, 12:829-42. 10.1007\/s43390-024-00834-x","journal-title":"Spine Deform"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1016\/j.wneu.2018.04.095","article-title":"Neurovascular relationships of S2AI screw placement: anatomic study","volume":"116","author":"Abdul-Jabbar A","year":"2018","unstructured":"Abdul-Jabbar A, Yilmaz E, Iwanaga J, et al.. Neurovascular relationships of S2AI screw placement: anatomic study. World Neurosurg. 2018, 116:e108-12. 10.1016\/j.wneu.2018.04.095","journal-title":"World Neurosurg"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.17.00052","article-title":"The free-hand technique for S2-alar-iliac screw placement: a safe and effective method for sacropelvic fixation in adult spinal deformity","volume":"100","author":"Shillingford JN","year":"2018","unstructured":"Shillingford JN, Laratta JL, Tan LA, et al.. The free-hand technique for S2-alar-iliac screw placement: a safe and effective method for sacropelvic fixation in adult spinal deformity. J Bone Joint Surg Am. 2018, 100:334-42. 10.2106\/JBJS.17.00052","journal-title":"J Bone Joint Surg Am"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1016\/j.wneu.2020.08.123","article-title":"Surgical technique and accuracy of S2 alar-iliac screw insertion using intraoperative O-arm navigation: an analysis of 120 screws","volume":"144","author":"Tamaki R","year":"2020","unstructured":"Tamaki R, Wada K, Okazaki K. Surgical technique and accuracy of S2 alar-iliac screw insertion using intraoperative O-arm navigation: an analysis of 120 screws. World Neurosurg. 2020, 144:e326-30. 10.1016\/j.wneu.2020.08.123","journal-title":"World Neurosurg"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.1097\/BRS.0000000000002694","article-title":"Human versus robot: a propensity-matched analysis of the accuracy of free hand versus robotic guidance for placement of S2 alar-iliac (S2AI) screws","volume":"43","author":"Shillingford JN","year":"2018","unstructured":"Shillingford JN, Laratta JL, Park PJ, et al.. Human versus robot: a propensity-matched analysis of the accuracy of free hand versus robotic guidance for placement of S2 alar-iliac (S2AI) screws. Spine (Phila Pa 1976). 2018, 43:E1297-304. 10.1097\/BRS.0000000000002694","journal-title":"Spine (Phila Pa 1976)"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.1016\/j.clineuro.2017.03.020","article-title":"Leg symptoms associated with sacroiliac joint disorder and related pain","volume":"157","author":"Murakami E","year":"2017","unstructured":"Murakami E, Aizawa T, Kurosawa D, Noguchi K. Leg symptoms associated with sacroiliac joint disorder and related pain. Clin Neurol Neurosurg. 2017, 157:55-8. 10.1016\/j.clineuro.2017.03.020","journal-title":"Clin Neurol Neurosurg"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1097\/00007632-199403001-00014","article-title":"Anatomic consideration in the anterior approach to the sacro-iliac joint","volume":"19","author":"Ebraheim NA","year":"1994","unstructured":"Ebraheim NA, Padanilam TG, Waldrop JT, Yeasting RA. Anatomic consideration in the anterior approach to the sacro-iliac joint. Spine (Phila Pa 1976). 1994, 19:721-5. 10.1097\/00007632-199403001-00014","journal-title":"Spine (Phila Pa 1976)"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-200007000-00032","article-title":"Anatomy of the anterior sacroiliac joint with reference to lumbosacral nerves","volume":"376","author":"Atlihan D","year":"2000","unstructured":"Atlihan D, Tekdemir I, Ate\u015d Y, Elhan A. Anatomy of the anterior sacroiliac joint with reference to lumbosacral nerves. Clin Orthop Relat Res. 2000, 376:236-41. 10.1097\/00003086-200007000-00032","journal-title":"Clin Orthop Relat Res"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-021-99851-3","article-title":"Relation of the lumbosacral trunk to the sacro-iliac joint","volume":"11","author":"Grechenig P","year":"2021","unstructured":"Grechenig P, Grechenig C, Hohenberger G, et al.. Relation of the lumbosacral trunk to the sacro-iliac joint. Sci Rep. 2021, 11:20211. 10.1038\/s41598-021-99851-3","journal-title":"Sci Rep"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.1177\/230949901001800319","article-title":"Anatomy of L4 to S3 nerve roots","volume":"18","author":"Waikakul S","year":"2010","unstructured":"Waikakul S, Chandraphak S, Sangthongsil P. Anatomy of L4 to S3 nerve roots. J Orthop Surg (Hong Kong). 2010, 18:352-5. 10.1177\/230949901001800319","journal-title":"J Orthop Surg (Hong Kong)"},{"key":"ref15","doi-asserted-by":"publisher","DOI":"10.1007\/s00276-020-02578-5","article-title":"Does the L5 spinal nerve move? Anatomical evaluation with implications for postoperative L5 nerve palsy","volume":"43","author":"Ishak B","year":"2021","unstructured":"Ishak B, Kikuta S, Scullen T, et al.. Does the L5 spinal nerve move? Anatomical evaluation with implications for postoperative L5 nerve palsy. Surg Radiol Anat. 2021, 43:813-8. 10.1007\/s00276-020-02578-5","journal-title":"Surg Radiol Anat"}],"container-title":["Cureus"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cureus.com\/articles\/313914-a-misplaced-s2-alar-iliac-screw-causing-l5-spinal-nerve-injury-a-report-of-a-rare-case","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,11,14]],"date-time":"2024-11-14T05:16:43Z","timestamp":1731561403000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cureus.com\/articles\/313914-a-misplaced-s2-alar-iliac-screw-causing-l5-spinal-nerve-injury-a-report-of-a-rare-case"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,11,13]]},"references-count":15,"URL":"https:\/\/doi.org\/10.7759\/cureus.73638","relation":{},"ISSN":["2168-8184"],"issn-type":[{"value":"2168-8184","type":"print"}],"subject":[],"published":{"date-parts":[[2024,11,13]]}}}