{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,8,23]],"date-time":"2025-08-23T05:28:06Z","timestamp":1755926886891,"version":"3.30.0"},"reference-count":15,"publisher":"Springer Science and Business Media LLC","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2024,11,29]]},"DOI":"10.7759\/cureus.74734","type":"journal-article","created":{"date-parts":[[2024,11,29]],"date-time":"2024-11-29T12:25:57Z","timestamp":1732883157000},"source":"Crossref","is-referenced-by-count":1,"title":["Evaluation of the Adequacy of Using the Supraglottic Airway Device (i-gel\u00ae) in Cases With Epiglottic Masses: A Mannequin Simulation Study"],"prefix":"10.7759","author":[{"given":"Tomoyuki","family":"Matsumoto","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tatsushige","family":"Iwamoto","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yasufumi","family":"Nakajima","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kei","family":"Houri","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takatoshi","family":"Tsujimoto","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hiroatsu","family":"Sakamoto","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Atsuhiro","family":"Kitaura","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yoshinobu","family":"Nakayama","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1177\/1971400915594517","article-title":"Epiglottic masses identified on CT imaging: a case report and review of the broad differential diagnosis","volume":"28","author":"Tresley J","year":"2015","unstructured":"Tresley J, Saraf-Lavi E, Kryvenko ON, Sargi Z. Epiglottic masses identified on CT imaging: a case report and review of the broad differential diagnosis. Neuroradiol J. 2015, 28:347-53. 10.1177\/1971400915594517","journal-title":"Neuroradiol J"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.7759\/cureus.35863","article-title":"A case report of an unusual presentation of epiglottic cyst causing airway obstruction in an adult","volume":"15","author":"Varathan V","year":"2023","unstructured":"Varathan V, Mat Baki M, Kalimuthu S. A case report of an unusual presentation of epiglottic cyst causing airway obstruction in an adult. Cureus. 2023, 15:e35863. 10.7759\/cureus.35863","journal-title":"Cureus"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1097\/MD.0000000000034026","article-title":"Difficult endotracheal intubation due to a large epiglottic cyst: a case report","volume":"102","author":"Zhang R","year":"2023","unstructured":"Zhang R, Jiang X, Feng J. Difficult endotracheal intubation due to a large epiglottic cyst: a case report. Medicine (Baltimore). 2023, 102:e34026. 10.1097\/MD.0000000000034026","journal-title":"Medicine (Baltimore)"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1097\/ALN.0000000000004002","article-title":"2022 American Society of Anesthesiologists practice guidelines for management of the difficult airway","volume":"136","author":"Apfelbaum JL","year":"2022","unstructured":"Apfelbaum JL, Hagberg CA, Connis RT, et al.. 2022 American Society of Anesthesiologists practice guidelines for management of the difficult airway. Anesthesiology. 2022, 136:31-81. 10.1097\/ALN.0000000000004002","journal-title":"Anesthesiology"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1097\/AIA.0000000000000457","article-title":"Innovative (and safe) techniques with supraglottic airways","volume":"62","author":"Herrera K","year":"2024","unstructured":"Herrera K, Tufail B, Osborn I. Innovative (and safe) techniques with supraglottic airways. Int Anesthesiol Clin. 2024, 62:91-100. 10.1097\/AIA.0000000000000457","journal-title":"Int Anesthesiol Clin"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.1972.tb08233.x","article-title":"Epiglottic cysts","volume":"27","author":"ApIvor D","year":"1972","unstructured":"ApIvor D. Epiglottic cysts. Anaesthesia. 1972, 27:355. 10.1111\/j.1365-2044.1972.tb08233.x","journal-title":"Anaesthesia"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.5005\/jp-journals-10023-1122","article-title":"A clinical study of laryngeal cysts","volume":"6","author":"Shaik F","year":"2016","unstructured":"Shaik F, Chowdary K. A clinical study of laryngeal cysts. Int J Phonosurg Laryngol. 2016, 6:53-6. 10.5005\/jp-journals-10023-1122","journal-title":"Int J Phonosurg Laryngol"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.7181\/acfs.2017.18.4.223","article-title":"Advantages, disadvantages, indications, contraindications and surgical technique of laryngeal airway mask","volume":"18","author":"Jannu A","year":"2017","unstructured":"Jannu A, Shekar A, Balakrishna R, Sudarshan H, Veena GC, Bhuvaneshwari S. Advantages, disadvantages, indications, contraindications and surgical technique of laryngeal airway mask. Arch Craniofac Surg. 2017, 18:223-9. 10.7181\/acfs.2017.18.4.223","journal-title":"Arch Craniofac Surg"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.1016\/j.bja.2018.01.015","article-title":"Epiglottis folding double with supraglottic airway devices","volume":"120","author":"van Zundert AA","year":"2018","unstructured":"van Zundert AA, Wyssusek KH. Epiglottis folding double with supraglottic airway devices. Br J Anaesth. 2018, 120:884-5. 10.1016\/j.bja.2018.01.015","journal-title":"Br J Anaesth"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.1097\/ALN.0000000000004946","article-title":"Classification of epiglottal displacement","volume":"141","author":"Suzuki A","year":"2024","unstructured":"Suzuki A, Yamada N, Seki K, Hotta K. Classification of epiglottal displacement. Anesthesiology. 2024, 141:161-2. 10.1097\/ALN.0000000000004946","journal-title":"Anesthesiology"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1111\/anae.13153","article-title":"Incidence of and risk factors for difficult ventilation via a supraglottic airway device in a population of 14,480 patients from South-East Asia","volume":"70","author":"Saito T","year":"2015","unstructured":"Saito T, Liu W, Chew ST, Ti LK. Incidence of and risk factors for difficult ventilation via a supraglottic airway device in a population of 14,480 patients from South-East Asia. Anaesthesia. 2015, 70:1079-83. 10.1111\/anae.13153","journal-title":"Anaesthesia"},{"key":"ref12","article-title":"Utility of McGRATH MAC for a patient with a large epiglottic cyst [Article in Japanese]","volume":"65","author":"Takahashi K","year":"2016","unstructured":"Takahashi K, Saima S, Arai T, Okuda Y. Utility of McGRATH MAC for a patient with a large epiglottic cyst [Article in Japanese]. Masui Jpn J Anesthesiol. 2016, 65:599-600.","journal-title":"Masui Jpn J Anesthesiol"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1002\/ccr3.5475","article-title":"Unexpected difficult airway due to an undiagnosed congenital lingual thyroglossal duct cyst in a neonate without stridor: A case report","volume":"10","author":"Kohashi Y","year":"2022","unstructured":"Kohashi Y, Yamamoto T, Igarashi M, Nishimaki H. Unexpected difficult airway due to an undiagnosed congenital lingual thyroglossal duct cyst in a neonate without stridor: A case report. Clin Case Rep. 2022, 10:e05475. 10.1002\/ccr3.5475","journal-title":"Clin Case Rep"},{"key":"ref14","article-title":"Oncocytic cyst of the larynx: an unusual occurrence","volume":"27","author":"Salerno G","year":"2007","unstructured":"Salerno G, Mignogna C, Cavaliere M, D'Angelo L, Galli V. Oncocytic cyst of the larynx: an unusual occurrence. Acta Otorhinolaryngol Ital. 2007, 27:212-5.","journal-title":"Acta Otorhinolaryngol Ital"},{"key":"ref15","doi-asserted-by":"publisher","DOI":"10.1046\/j.1365-2044.2003.03200.x","article-title":"Structure and process quality illustrated by fibreoptic intubation: analysis of 1612 cases","volume":"58","author":"Heidegger T","year":"2003","unstructured":"Heidegger T, Gerig HJ, Ulrich B, Schnider TW. Structure and process quality illustrated by fibreoptic intubation: analysis of 1612 cases. Anaesthesia. 2003, 58:734-9. 10.1046\/j.1365-2044.2003.03200.x","journal-title":"Anaesthesia"}],"container-title":["Cureus"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cureus.com\/articles\/317944-evaluation-of-the-adequacy-of-using-the-supraglottic-airway-device-i-gel-in-cases-with-epiglottic-masses-a-mannequin-simulation-study","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,11,29]],"date-time":"2024-11-29T12:25:59Z","timestamp":1732883159000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cureus.com\/articles\/317944-evaluation-of-the-adequacy-of-using-the-supraglottic-airway-device-i-gel-in-cases-with-epiglottic-masses-a-mannequin-simulation-study"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,11,29]]},"references-count":15,"URL":"https:\/\/doi.org\/10.7759\/cureus.74734","relation":{},"ISSN":["2168-8184"],"issn-type":[{"value":"2168-8184","type":"print"}],"subject":[],"published":{"date-parts":[[2024,11,29]]}}}