{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,12,1]],"date-time":"2024-12-01T05:08:23Z","timestamp":1733029703847,"version":"3.30.0"},"reference-count":14,"publisher":"Springer Science and Business Media LLC","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2024,11,30]]},"DOI":"10.7759\/cureus.74807","type":"journal-article","created":{"date-parts":[[2024,11,30]],"date-time":"2024-11-30T09:08:46Z","timestamp":1732957726000},"source":"Crossref","is-referenced-by-count":0,"title":["Iris Avulsion During Corneal Wound Hydration After Uneventful Cataract Extraction"],"prefix":"10.7759","author":[{"given":"Lampros","family":"Lamprogiannis","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Padmanabha P","family":"Syam","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Arsh","family":"Patel","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kaushal Pillai","family":"Syam","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"George","family":"Voyatzis","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1055\/s-2001-18388","article-title":"Retrospective analysis of 417 cases of contusion and rupture of the globe with frequent avoidable causes of trauma: the Erlangen Ocular Contusion-Registry (EOCR) 1985 - 1995 [Article in German]","volume":"218","author":"Viestenz A","year":"2001","unstructured":"Viestenz A, K\u00fcchle M. Retrospective analysis of 417 cases of contusion and rupture of the globe with frequent avoidable causes of trauma: the Erlangen Ocular Contusion-Registry (EOCR) 1985 - 1995 [Article in German]. Klin Monbl Augenheilkd. 2001, 218:662-9. 10.1055\/s-2001-18388","journal-title":"Klin Monbl Augenheilkd"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(99)00042-5","article-title":"Severe iridodialysis from phacoemulsification tip suction","volume":"25","author":"Oshika T","year":"1999","unstructured":"Oshika T, Amano S, Kato S. Severe iridodialysis from phacoemulsification tip suction. J Cataract Refract Surg. 1999, 25:873-5. 10.1016\/S0886-3350(99)00042-5","journal-title":"J Cataract Refract Surg"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.3126\/kumj.v12i3.13717","article-title":"Intraoperative complications of high volume sutureless cataract surgery in Nepal: a prospective study","volume":"12","author":"Limbu B","year":"2014","unstructured":"Limbu B, Jha HC. Intraoperative complications of high volume sutureless cataract surgery in Nepal: a prospective study. Kathmandu Univ Med J (KUMJ). 2014, 12:194-7. 10.3126\/kumj.v12i3.13717","journal-title":"Kathmandu Univ Med J (KUMJ)"},{"key":"ref4","article-title":"Complications of cataract surgery in patients with pseudoexfoliation syndrome","volume":"21","author":"Jawad M","year":"2009","unstructured":"Jawad M, Nadeem AU, Khan Au, Aftab M. Complications of cataract surgery in patients with pseudoexfoliation syndrome. J Ayub Med Coll Abbottabad. 2009, 21:33-6.","journal-title":"J Ayub Med Coll Abbottabad"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(02)01288-5","article-title":"Descemet\u2019s membrane detachment after cataract surgery: management and outcome","volume":"109","author":"Marcon AS","year":"2002","unstructured":"Marcon AS, Rapuano CJ, Jones MR, Laibson PR, Cohen EJ. Descemet\u2019s membrane detachment after cataract surgery: management and outcome. Ophthalmology. 2002, 109:2325-30. 10.1016\/S0161-6420(02)01288-5","journal-title":"Ophthalmology"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.125.7.889","article-title":"The spectrum of iatrogenic intraocular injuries caused by inadvertent cannula release during anterior segment surgery","volume":"125","author":"Rumelt S","year":"2007","unstructured":"Rumelt S, Kassif Y, Koropov M, et al.. The spectrum of iatrogenic intraocular injuries caused by inadvertent cannula release during anterior segment surgery. Arch Ophthalmol. 2007, 125:889-92. 10.1001\/archopht.125.7.889","journal-title":"Arch Ophthalmol"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1038\/sj.eye.6702292","article-title":"Ocular trauma caused by a loose slip-lock cannula during corneal hydration","volume":"20","author":"Bradshaw SE","year":"2006","unstructured":"Bradshaw SE, Shankar P, Maini R, Ragheb S. Ocular trauma caused by a loose slip-lock cannula during corneal hydration. Eye (Lond). 2006, 20:1432-4. 10.1038\/sj.eye.6702292","journal-title":"Eye (Lond)"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.2147\/OPTH.S83552","article-title":"Cataract surgery and methods of wound closure: a review","volume":"9","author":"Matossian C","year":"2015","unstructured":"Matossian C, Makari S, Potvin R. Cataract surgery and methods of wound closure: a review. Clin Ophthalmol. 2015, 9:921-8. 10.2147\/OPTH.S83552","journal-title":"Clin Ophthalmol"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2016.07.026","article-title":"Pressures generated during corneal wound hydration","volume":"42","author":"Sun MT","year":"2016","unstructured":"Sun MT, Wood M, Chan W, Casson R. Pressures generated during corneal wound hydration. J Cataract Refract Surg. 2016, 42:1383-4. 10.1016\/j.jcrs.2016.07.026","journal-title":"J Cataract Refract Surg"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.1186\/s12886-022-02615-4","article-title":"Isolated traumatic aniridia with full and partial iris expulsion in pseudophakic eyes","volume":"22","author":"Ichioka S","year":"2022","unstructured":"Ichioka S, Ishida A, Sugihara K, Sano I, Tanito M. Isolated traumatic aniridia with full and partial iris expulsion in pseudophakic eyes. BMC Ophthalmol. 2022, 22:390. 10.1186\/s12886-022-02615-4","journal-title":"BMC Ophthalmol"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0420.2005.00391.x","article-title":"Total iris expulsion through a sutureless cataract incision due to vomiting","volume":"83","author":"Slettedal JK","year":"2005","unstructured":"Slettedal JK, Bragad\u00f3ttir R. Total iris expulsion through a sutureless cataract incision due to vomiting. Acta Ophthalmol Scand. 2005, 83:111-2. 10.1111\/j.1600-0420.2005.00391.x","journal-title":"Acta Ophthalmol Scand"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1007\/s10792-018-0840-3","article-title":"Clinical risk factors associated with intraoperative floppy iris syndrome: a prospective study","volume":"39","author":"Kaczmarek IA","year":"2019","unstructured":"Kaczmarek IA, Prost ME, Wasyluk J. Clinical risk factors associated with intraoperative floppy iris syndrome: a prospective study. Int Ophthalmol. 2019, 39:541-9. 10.1007\/s10792-018-0840-3","journal-title":"Int Ophthalmol"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000000411","article-title":"Management of common iatrogenic iris defects induced by cataract surgery","volume":"47","author":"Foster GJ","year":"2021","unstructured":"Foster GJ, Ayres B, Fram N, et al.. Management of common iatrogenic iris defects induced by cataract surgery. J Cataract Refract Surg. 2021, 47:522-32. 10.1097\/j.jcrs.0000000000000411","journal-title":"J Cataract Refract Surg"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.1016\/S1529-1839(05)70280-3","article-title":"Use of the artificial iris implant in patients with aniridia","volume":"76","author":"Brown MJ1","year":"2005","unstructured":"Brown MJ1, Hardten DR, Knish K. Use of the artificial iris implant in patients with aniridia. Optometry. 2005, 76:157-64. 10.1016\/S1529-1839(05)70280-3","journal-title":"Optometry"}],"container-title":["Cureus"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cureus.com\/articles\/49617-iris-avulsion-during-corneal-wound-hydration-after-uneventful-cataract-extraction","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,11,30]],"date-time":"2024-11-30T09:08:47Z","timestamp":1732957727000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cureus.com\/articles\/49617-iris-avulsion-during-corneal-wound-hydration-after-uneventful-cataract-extraction"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,11,30]]},"references-count":14,"URL":"https:\/\/doi.org\/10.7759\/cureus.74807","relation":{},"ISSN":["2168-8184"],"issn-type":[{"value":"2168-8184","type":"print"}],"subject":[],"published":{"date-parts":[[2024,11,30]]}}}