{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,12,5]],"date-time":"2024-12-05T05:27:38Z","timestamp":1733376458818,"version":"3.30.1"},"reference-count":16,"publisher":"Springer Science and Business Media LLC","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2024,12,4]]},"DOI":"10.7759\/cureus.75092","type":"journal-article","created":{"date-parts":[[2024,12,4]],"date-time":"2024-12-04T14:43:52Z","timestamp":1733323432000},"source":"Crossref","is-referenced-by-count":0,"title":["Component Mix-Match for Anatomic Total Shoulder Arthroplasty Revision: A Case Report"],"prefix":"10.7759","author":[{"given":"Ilias","family":"Tsolis","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Fady","family":"Atia","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Malin","family":"Wijeratna","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","reference":[{"key":"ref1","unstructured":"Medical devices regulations. compliance and enforcement. (2024). Accessed: 17\/05\/2024: https:\/\/www.gov.uk\/government\/publications\/report-a-non-compliant-medical-device-enforcement-process."},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1080\/17453674.2020.1822066","article-title":"To mix or not to mix? Medicolegal implications of mixed components in total hip arthroplasty","volume":"91","author":"Peters RM","year":"2020","unstructured":"Peters RM, Hiemstra JT, Zijlstra WP, Bulstra SK, Stevens M. To mix or not to mix? Medicolegal implications of mixed components in total hip arthroplasty. Acta Orthop. 2020, 91:624-6. 10.1080\/17453674.2020.1822066","journal-title":"Acta Orthop"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1302\/2058-5241.6.210080","article-title":"EFORT recommendations for off-label use, mix & match and mismatch in hip and knee arthroplasty","volume":"6","author":"Tucker K","year":"2021","unstructured":"Tucker K, G\u00fcnther KP, Kjaersgaard-Andersen P, et al.. EFORT recommendations for off-label use, mix &amp; match and mismatch in hip and knee arthroplasty. EFORT Open Rev. 2021, 6:982-1005. 10.1302\/2058-5241.6.210080","journal-title":"EFORT Open Rev"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2017.09.047","article-title":"Long-term survival of total hip arthroplasty using implants from different manufacturers","volume":"33","author":"Taylor JW","year":"2018","unstructured":"Taylor JW, Frampton C, Rothwell AG. Long-term survival of total hip arthroplasty using implants from different manufacturers. J Arthroplasty. 2018, 33:491-5. 10.1016\/j.arth.2017.09.047","journal-title":"J Arthroplasty"},{"key":"ref5","article-title":"Mixing of components from different manufacturers in total hip arthroplasty: prevalence and comparative outcomes","volume":"86","author":"Tucker K","year":"2015","unstructured":"Tucker K, Pickford M, Newell C, Howard P, Hunt LP, Blom AW. Mixing of components from different manufacturers in total hip arthroplasty: prevalence and comparative outcomes. Acta Orthop. 2015, 86:671-7.","journal-title":"Acta Orthop"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.5435\/JAAOS-D-13-00173","article-title":"Multiple epiphyseal dysplasia","volume":"23","author":"Anthony S","year":"2015","unstructured":"Anthony S, Munk R, Skakun W, Masini M. Multiple epiphyseal dysplasia. J Am Acad Orthop Surg. 2015, 23:164-72. 10.5435\/JAAOS-D-13-00173","journal-title":"J Am Acad Orthop Surg"},{"key":"ref7","article-title":"Questionnaire on the perceptions of patients about shoulder surgery","volume":"78","author":"Dawson J","year":"1996","unstructured":"Dawson J, Fitzpatrick R, Carr A. Questionnaire on the perceptions of patients about shoulder surgery. J Bone Joint Surg Br. 1996, 78:593-600.","journal-title":"J Bone Joint Surg Br"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.3389\/fnhum.2019.00086","article-title":"The historical roots of visual analog scale in psychology as revealed by reference publication year spectroscopy","volume":"13","author":"Yeung AW","year":"2019","unstructured":"Yeung AW, Wong NS. The historical roots of visual analog scale in psychology as revealed by reference publication year spectroscopy. Front Hum Neurosci. 2019, 13:86. 10.3389\/fnhum.2019.00086","journal-title":"Front Hum Neurosci"},{"key":"ref9","unstructured":"Equinoxe Platform Shoulder System . (2014). Accessed. 07\/2024: https:\/\/www.exac.co.uk\/shoulder\/equinoxe-platform-system\/."},{"key":"ref10","unstructured":"PubMed database search for \"shoulder arthroplasty mix-match\". (2024). Accessed. 01 June 2024: https:\/\/pubmed.ncbi.nlm.nih.gov\/."},{"key":"ref11","unstructured":"Mix and match (MM) in conventional anatomical total shoulder replacement. (2021). Accessed. 01 June, 2024: https:\/\/bess.ac.uk\/membership-information-and-resources\/."},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1186\/s42836-022-00113-y","article-title":"Risk factors associated with surgical site infections following joint replacement surgery: a narrative review","volume":"4","author":"Li T","year":"2022","unstructured":"Li T, Zhang H, Chan PK, Fung WC, Fu H, Chiu KY. Risk factors associated with surgical site infections following joint replacement surgery: a narrative review. Arthroplasty. 2022, 4:11. 10.1186\/s42836-022-00113-y","journal-title":"Arthroplasty"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1186\/s12891-020-03219-z","article-title":"Radiographic performance depends on the radial glenohumeral mismatch in total shoulder arthroplasty","volume":"21","author":"Hasler A","year":"2020","unstructured":"Hasler A, Meyer DC, Tondelli T, Dietrich T, Gerber C. Radiographic performance depends on the radial glenohumeral mismatch in total shoulder arthroplasty. BMC Musculoskelet Disord. 2020, 21:206. 10.1186\/s12891-020-03219-z","journal-title":"BMC Musculoskelet Disord"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.1016\/j.jse.2018.11.059","article-title":"The effect of glenohumeral radial mismatch on different augmented total shoulder arthroplasty glenoid designs: a finite element analysis","volume":"28","author":"Sabesan VJ","year":"2019","unstructured":"Sabesan VJ, Lima DJ, Whaley JD, Pathak V, Zhang L. The effect of glenohumeral radial mismatch on different augmented total shoulder arthroplasty glenoid designs: a finite element analysis. J Shoulder Elbow Surg. 2019, 28:1146-53. 10.1016\/j.jse.2018.11.059","journal-title":"J Shoulder Elbow Surg"},{"key":"ref15","doi-asserted-by":"publisher","DOI":"10.1016\/j.jses.2019.09.007","article-title":"The effect of radial mismatch on radiographic glenoid loosening","volume":"3","author":"Schoch BS","year":"2019","unstructured":"Schoch BS, Wright TW, Zuckerman JD, Flurin PH, Bolch C, Roche CP, King JJ. The effect of radial mismatch on radiographic glenoid loosening. JSES Open Access. 2019, 3:287-91. 10.1016\/j.jses.2019.09.007","journal-title":"JSES Open Access"},{"key":"ref16","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-200212000-00010","article-title":"The influence of glenohumeral prosthetic mismatch on glenoid radiolucent lines: results of a multicenter study","volume":"84","author":"Walch G","year":"2002","unstructured":"Walch G, Edwards TB, Boulahia A, Boileau P, Mole D, Adeleine P. The influence of glenohumeral prosthetic mismatch on glenoid radiolucent lines: results of a multicenter study. J Bone Joint Surg Am. 2002, 84:2186-91. 10.2106\/00004623-200212000-00010","journal-title":"J Bone Joint Surg Am"}],"container-title":["Cureus"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cureus.com\/articles\/274409-component-mix-match-for-anatomic-total-shoulder-arthroplasty-revision-a-case-report","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,12,4]],"date-time":"2024-12-04T14:43:56Z","timestamp":1733323436000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cureus.com\/articles\/274409-component-mix-match-for-anatomic-total-shoulder-arthroplasty-revision-a-case-report"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,12,4]]},"references-count":16,"URL":"https:\/\/doi.org\/10.7759\/cureus.75092","relation":{},"ISSN":["2168-8184"],"issn-type":[{"value":"2168-8184","type":"print"}],"subject":[],"published":{"date-parts":[[2024,12,4]]}}}