{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,12,23]],"date-time":"2024-12-23T12:40:09Z","timestamp":1734957609460,"version":"3.32.0"},"reference-count":13,"publisher":"Springer Science and Business Media LLC","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2024,12,23]]},"DOI":"10.7759\/cureus.76249","type":"journal-article","created":{"date-parts":[[2024,12,23]],"date-time":"2024-12-23T12:05:36Z","timestamp":1734955536000},"source":"Crossref","is-referenced-by-count":0,"title":["Foreign Body Entrapment on the Bearing Surface in Total Hip Arthroplasty: A Report of Three Cases"],"prefix":"10.7759","author":[{"given":"Hisatoshi","family":"Ishikura","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kenichi","family":"Kato","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Atsushi","family":"Madachi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takeyuki","family":"Tanaka","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Toru","family":"Nishiwaki","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(07)60457-7","article-title":"The operation of the century: total hip replacement","volume":"370","author":"Learmonth ID","year":"2007","unstructured":"Learmonth ID, Young C, Rorabeck C. The operation of the century: total hip replacement. Lancet. 2007, 370:1508-1519. 10.1016\/S0140-6736(07)60457-7","journal-title":"Lancet"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2023.04.029","article-title":"Complication rate after primary total hip arthroplasty using the posterior approach and enabling technology: a consecutive series of 2,888 hips","volume":"38","author":"Anderson CG","year":"2023","unstructured":"Anderson CG, Jang SJ, Brilliant ZR, Mayman DJ, Vigdorchik JM, Jerabek SA, Sculco PK. Complication rate after primary total hip arthroplasty using the posterior approach and enabling technology: a consecutive series of 2,888 hips. J Arthroplasty. 2023, 38:S119-S123.e3. 10.1016\/j.arth.2023.04.029","journal-title":"J Arthroplasty"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1503\/cjs.012019","article-title":"Direct anterior versus posterior approach for total hip arthroplasty: a multicentre, prospective, randomized clinical trial","volume":"63","author":"Moerenhout K","year":"2020","unstructured":"Moerenhout K, Derome P, Laflamme GY, Leduc S, Gaspard HS, Benoit B. Direct anterior versus posterior approach for total hip arthroplasty: a multicentre, prospective, randomized clinical trial. Can J Surg. 2020, 63:E412-E417. 10.1503\/cjs.012019","journal-title":"Can J Surg"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.99B6.38053","article-title":"The direct anterior approach in total hip arthroplasty: a systematic review of the literature","volume":"99-B","author":"Meermans G","year":"2017","unstructured":"Meermans G, Konan S, Das R, Volpin A, Haddad FS. The direct anterior approach in total hip arthroplasty: a systematic review of the literature. Bone Joint J. 2017, 99-B:732-740. 10.1302\/0301-620X.99B6.38053","journal-title":"Bone Joint J"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2007.10.027","article-title":"The effect of entrapped bone particles on the surface morphology and wear of polyethylene","volume":"24","author":"Mimnaugh KD","year":"2009","unstructured":"Mimnaugh KD, Yao JQ, Laurent MP, Crowninshield R, Mason JJ, Blanchard C. The effect of entrapped bone particles on the surface morphology and wear of polyethylene. J Arthroplasty. 2009, 24:303-309. 10.1016\/j.arth.2007.10.027","journal-title":"J Arthroplasty"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.5312\/wjo.v6.i2.172","article-title":"Biological response to prosthetic debris","volume":"6","author":"Bitar D","year":"2015","unstructured":"Bitar D, Parvizi J. Biological response to prosthetic debris. World J Orthop. 2015, 6:172-189. 10.5312\/wjo.v6.i2.172","journal-title":"World J Orthop"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.3390\/jcm12206615","article-title":"Wear, osteolysis, and aseptic loosening following total hip arthroplasty in young patients with highly cross-linked polyethylene: a review of studies with a follow-up of over 15 years","volume":"12","author":"Deans CF","year":"2023","unstructured":"Deans CF, Buckner BC, Garvin KL. Wear, osteolysis, and aseptic loosening following total hip arthroplasty in young patients with highly cross-linked polyethylene: a review of studies with a follow-up of over 15 years. J Clin Med. 2023, 12:6615. 10.3390\/jcm12206615","journal-title":"J Clin Med"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.F.01489","article-title":"Isolated fracture of the ceramic head after third-generation alumina-on-alumina total hip arthroplasty","volume":"90","author":"Koo KH","year":"2008","unstructured":"Koo KH, Ha YC, Jung WH, Kim SR, Yoo JJ, Kim HJ. Isolated fracture of the ceramic head after third-generation alumina-on-alumina total hip arthroplasty. J Bone Joint Surg Am. 2008, 90:329-336. 10.2106\/JBJS.F.01489","journal-title":"J Bone Joint Surg Am"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.7759\/cureus.13726","article-title":"Late onset atraumatic ceramic head fracture of a hybrid ceramic bearings total hip arthroplasty","volume":"13","author":"Papaioannou I","year":"2021","unstructured":"Papaioannou I, Repantis T, Pantazidou G, Baikousis A, Korovessis P. Late onset atraumatic ceramic head fracture of a hybrid ceramic bearings total hip arthroplasty. Cureus. 2021, 13:e13726. 10.7759\/cureus.13726","journal-title":"Cureus"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.J.01612","article-title":"Pseudotumors associated with total hip arthroplasty","volume":"94","author":"Daniel J","year":"2012","unstructured":"Daniel J, Holland J, Quigley L, Sprague S, Bhandari M. Pseudotumors associated with total hip arthroplasty. J Bone Joint Surg Am. 2012, 94:86-93. 10.2106\/JBJS.J.01612","journal-title":"J Bone Joint Surg Am"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.7759\/cureus.60810","article-title":"Adverse metal reaction in a case of metal-on-polyethylene hip arthroplasty","volume":"16","author":"Singh N","year":"2024","unstructured":"Singh N, Awasthi A, Pisulkar G, Taywade S, Samal N. Adverse metal reaction in a case of metal-on-polyethylene hip arthroplasty. Cureus. 2024, 16:e60810. 10.7759\/cureus.60810","journal-title":"Cureus"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.93B2.25770","article-title":"Entrapment of the sciatic nerve following closed reduction of a dislocated revision total hip replacement","volume":"93","author":"Chan JH","year":"2011","unstructured":"Chan JH, Ballal MS, Dheerendra S, Sanchez-Ballester J, Pydisetty RV. Entrapment of the sciatic nerve following closed reduction of a dislocated revision total hip replacement. J Bone Joint Surg Br. 2011, 93:274-276. 10.1302\/0301-620X.93B2.25770","journal-title":"J Bone Joint Surg Br"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1016\/s0883-5403(98)80018-1","article-title":"Drain entrapment and titanium to ceramic head deposition: two unique complications following closed reduction of a dislocated total hip arthroplasty","volume":"13","author":"Luchetti WT","year":"1998","unstructured":"Luchetti WT, Copley LA, Vresilovic EJ, Black J, Steinberg ME. Drain entrapment and titanium to ceramic head deposition: two unique complications following closed reduction of a dislocated total hip arthroplasty. J Arthroplasty. 1998, 13:713-717. 10.1016\/s0883-5403(98)80018-1","journal-title":"J Arthroplasty"}],"container-title":["Cureus"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cureus.com\/articles\/327170-foreign-body-entrapment-on-the-bearing-surface-in-total-hip-arthroplasty-a-report-of-three-cases","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,12,23]],"date-time":"2024-12-23T12:05:37Z","timestamp":1734955537000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cureus.com\/articles\/327170-foreign-body-entrapment-on-the-bearing-surface-in-total-hip-arthroplasty-a-report-of-three-cases"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,12,23]]},"references-count":13,"URL":"https:\/\/doi.org\/10.7759\/cureus.76249","relation":{},"ISSN":["2168-8184"],"issn-type":[{"value":"2168-8184","type":"print"}],"subject":[],"published":{"date-parts":[[2024,12,23]]}}}