{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,1,23]],"date-time":"2025-01-23T05:17:26Z","timestamp":1737609446282,"version":"3.33.0"},"reference-count":16,"publisher":"Springer Science and Business Media LLC","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2025,1,21]]},"DOI":"10.7759\/cureus.77801","type":"journal-article","created":{"date-parts":[[2025,1,22]],"date-time":"2025-01-22T07:12:35Z","timestamp":1737529955000},"source":"Crossref","is-referenced-by-count":0,"title":["Successful Management of a Keratoconus Patient With Rarely Used Large-Diameter Corneal RGP Contact Lenses: A Case Report"],"prefix":"10.7759","author":[{"given":"Ahmed","family":"Almaweri","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1016\/j.exer.2020.108328","article-title":"Genetics vs chronic corneal mechanical trauma in the etiology of keratoconus","volume":"202","author":"Rabinowitz YS","year":"2021","unstructured":"Rabinowitz YS, Galvis V, Tello A, Rueda D, Garc\u00eda JD. Genetics vs chronic corneal mechanical trauma in the etiology of keratoconus. Exp Eye Res. 2021, 202:108328. 10.1016\/j.exer.2020.108328","journal-title":"Exp Eye Res"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1136\/bjophthalmol-2017-311391","article-title":"Prevalence of keratoconus in paediatric patients in Riyadh, Saudi Arabia","volume":"102","author":"Torres Netto EA","year":"2018","unstructured":"Torres Netto EA, Al-Otaibi WM, Hafezi NL, Kling S, Al-Farhan HM, Randleman JB, Hafezi F. Prevalence of keratoconus in paediatric patients in Riyadh, Saudi Arabia. Br J Ophthalmol. 2018, 102:1436-41. 10.1136\/bjophthalmol-2017-311391","journal-title":"Br J Ophthalmol"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1016\/j.clae.2021.101559","article-title":"Keratoconus: an updated review","volume":"45","author":"Santodomingo-Rubido J","year":"2022","unstructured":"Santodomingo-Rubido J, Carracedo G, Suzaki A, Villa-Collar C, Vincent SJ, Wolffsohn JS. Keratoconus: an updated review. Cont Lens Anterior Eye. 2022, 45:101559. 10.1016\/j.clae.2021.101559","journal-title":"Cont Lens Anterior Eye"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.5935\/0004-2749.20160025","article-title":"Descriptive analysis of the type and design of contact lenses fitted according to keratoconus severity and morphology","volume":"79","author":"Lunardi LH","year":"2016","unstructured":"Lunardi LH, Arroyo D, Andrade Sobrinho MV, Lipener C, Rosa JM. Descriptive analysis of the type and design of contact lenses fitted according to keratoconus severity and morphology. Arq Bras Oftalmol. 2016, 79:82-4. 10.5935\/0004-2749.20160025","journal-title":"Arq Bras Oftalmol"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.3980\/j.issn.2222-3959.2011.05.13","article-title":"Rigid contact lens fitting based on keratometry readings in keratoconus patients: predicting formula","volume":"4","author":"Rajabi MT","year":"2011","unstructured":"Rajabi MT, Mohajernezhad-Fard Z, Naseri SK, et al.. Rigid contact lens fitting based on keratometry readings in keratoconus patients: predicting formula. Int J Ophthalmol. 2011, 4:525-8. 10.3980\/j.issn.2222-3959.2011.05.13","journal-title":"Int J Ophthalmol"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1016\/s1367-0484(02)00006-1","article-title":"Optimising RGP lens fitting in normal eyes using 3D topographic data","volume":"25","author":"Van der Worp E","year":"2002","unstructured":"Van der Worp E, de Brabander J, Lubberman B, Marin G, Hendrikse F. Optimising RGP lens fitting in normal eyes using 3D topographic data. Cont Lens Anterior Eye. 2002, 25:95-9. 10.1016\/s1367-0484(02)00006-1","journal-title":"Cont Lens Anterior Eye"},{"key":"ref7","article-title":"Baseline findings in the Collaborative Longitudinal Evaluation of Keratoconus (CLEK) study","volume":"39","author":"Zadnik K","year":"1998","unstructured":"Zadnik K, Barr JT, Edrington TB, et al.. Baseline findings in the Collaborative Longitudinal Evaluation of Keratoconus (CLEK) study. Invest Ophthalmol Vis Sci. 1998, 39:2537-46.","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1016\/j.clae.2008.07.001","article-title":"30 years of contact lens prescribing for keratoconic patients in Turkey","volume":"32","author":"Bilgin LK","year":"2009","unstructured":"Bilgin LK, Yilmaz S, Araz B, Y\u00fcksel SB, Sezen T. 30 years of contact lens prescribing for keratoconic patients in Turkey. Cont Lens Anterior Eye. 2009, 32:16-21. 10.1016\/j.clae.2008.07.001","journal-title":"Cont Lens Anterior Eye"},{"key":"ref9","article-title":"Contact Lens Practice","author":"Efron N","year":"2023","unstructured":"Efron N. Contact Lens Practice. Elsevier, 2023."},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.4274\/tjo.galenos.2020.70481","article-title":"Update on contact lens treatment of keratoconus","volume":"50","author":"\u015eeng\u00f6r T","year":"2020","unstructured":"\u015eeng\u00f6r T, Ayd\u0131n Kurna S. Update on contact lens treatment of keratoconus. Turk J Ophthalmol. 2020, 50:234-44. 10.4274\/tjo.galenos.2020.70481","journal-title":"Turk J Ophthalmol"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1016\/j.clae.2011.08.007","article-title":"Cone location and correction of keratoconus with rigid gas-permeable contact lenses","volume":"35","author":"Nejabat M","year":"2012","unstructured":"Nejabat M, Khalili MR, Dehghani C. Cone location and correction of keratoconus with rigid gas-permeable contact lenses. Cont Lens Anterior Eye. 2012, 35:17-21. 10.1016\/j.clae.2011.08.007","journal-title":"Cont Lens Anterior Eye"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1016\/S1888-4296(11)70036-X","article-title":"Effect of lens diameter on lens performance and initial comfort of two types of GP lenses for keratoconus: a pilot study","volume":"4","author":"Sorbara L","year":"2011","unstructured":"Sorbara L, Mueller K. Effect of lens diameter on lens performance and initial comfort of two types of GP lenses for keratoconus: a pilot study. J Optom. 2011, 4:22-9. 10.1016\/S1888-4296(11)70036-X","journal-title":"J Optom"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1016\/j.jtos.2019.12.001","article-title":"Cytomorphological assessment of the lid margin in relation to symptoms, contact lens wear and lid wiper epitheliopathy","volume":"18","author":"Muntz A","year":"2020","unstructured":"Muntz A, Subbaraman LN, Craig JP, Jones L. Cytomorphological assessment of the lid margin in relation to symptoms, contact lens wear and lid wiper epitheliopathy. Ocul Surf. 2020, 18:214-20. 10.1016\/j.jtos.2019.12.001","journal-title":"Ocul Surf"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.1097\/ICL.0b013e3181e52dd1","article-title":"Visual acuity and ocular aberrations with different rigid gas permeable lens fittings in keratoconus","volume":"36","author":"Jinabhai A","year":"2010","unstructured":"Jinabhai A, Radhakrishnan H, O'Donnell C. Visual acuity and ocular aberrations with different rigid gas permeable lens fittings in keratoconus. Eye Contact Lens. 2010, 36:233-7. 10.1097\/ICL.0b013e3181e52dd1","journal-title":"Eye Contact Lens"},{"key":"ref15","doi-asserted-by":"publisher","DOI":"10.1111\/j.1444-0938.2007.00195.x","article-title":"New perspectives on keratoconus as revealed by corneal confocal microscopy","volume":"91","author":"Efron N","year":"2008","unstructured":"Efron N, Hollingsworth JG. New perspectives on keratoconus as revealed by corneal confocal microscopy. Clin Exp Optom. 2008, 91:34-55. 10.1111\/j.1444-0938.2007.00195.x","journal-title":"Clin Exp Optom"},{"key":"ref16","doi-asserted-by":"publisher","DOI":"10.4103\/0301-4738.116066","article-title":"Contact lens in keratoconus","volume":"61","author":"Rathi VM","year":"2013","unstructured":"Rathi VM, Mandathara PS, Dumpati S. Contact lens in keratoconus. Indian J Ophthalmol. 2013, 61:410-5. 10.4103\/0301-4738.116066","journal-title":"Indian J Ophthalmol"}],"container-title":["Cureus"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cureus.com\/articles\/328565-successful-management-of-a-keratoconus-patient-with-rarely-used-large-diameter-corneal-rgp-contact-lenses-a-case-report","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,1,22]],"date-time":"2025-01-22T07:12:41Z","timestamp":1737529961000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cureus.com\/articles\/328565-successful-management-of-a-keratoconus-patient-with-rarely-used-large-diameter-corneal-rgp-contact-lenses-a-case-report"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,1,21]]},"references-count":16,"URL":"https:\/\/doi.org\/10.7759\/cureus.77801","relation":{},"ISSN":["2168-8184"],"issn-type":[{"value":"2168-8184","type":"print"}],"subject":[],"published":{"date-parts":[[2025,1,21]]}}}