{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,15]],"date-time":"2025-02-15T12:40:14Z","timestamp":1739623214786,"version":"3.37.1"},"reference-count":67,"publisher":"Springer Science and Business Media LLC","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2025,2,15]]},"DOI":"10.7759\/cureus.79042","type":"journal-article","created":{"date-parts":[[2025,2,15]],"date-time":"2025-02-15T12:01:36Z","timestamp":1739620896000},"source":"Crossref","is-referenced-by-count":0,"title":["Conservative Treatment of Sigmoid Diverticulum Perforation Secondary to Migrated Biliary Plastic Prostheses Inserted by Endoscopic Retrograde Cholangiopancreatography: A Case Report of an Unusual Adverse Event and Literature Review"],"prefix":"10.7759","author":[{"given":"Andr\u00e9","family":"Orsini-Ardengh","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Anna Carolina","family":"Orsini-Arman","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bruna","family":"Haueisen Figueiredo Zwetkoff","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Otavio","family":"Micelli-Neto","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rodrigo Ca\u00f1ada  T","family":"Surjan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jose  C","family":"Ardengh","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1016\/j.gtc.2024.08.011","article-title":"Biliary endoscopic retrograde cholangiopancreatography","volume":"53","author":"AbiMansour JP","year":"2024","unstructured":"AbiMansour JP, Martin JA. Biliary endoscopic retrograde cholangiopancreatography. Gastroenterol Clin North Am. 2024, 53:627-42. 10.1016\/j.gtc.2024.08.011","journal-title":"Gastroenterol Clin North Am"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1055\/a-0659-9864","article-title":"Endoscopic biliary stenting: indications, choice of stents, and results: European Society of Gastrointestinal Endoscopy (ESGE) Clinical Guideline - Updated October 2017","volume":"50","author":"Dumonceau JM","year":"2018","unstructured":"Dumonceau JM, Tringali A, Papanikolaou IS, et al.. Endoscopic biliary stenting: indications, choice of stents, and results: European Society of Gastrointestinal Endoscopy (ESGE) Clinical Guideline - Updated October 2017. Endoscopy. 2018, 50:910-30. 10.1055\/a-0659-9864","journal-title":"Endoscopy"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1016\/j.gie.2011.07.010","article-title":"Complications of ERCP","volume":"75","author":"Anderson MA","year":"2012","unstructured":"Anderson MA, Fisher L, Jain R, et al.. Complications of ERCP. Gastrointest Endosc. 2012, 75:467-73. 10.1016\/j.gie.2011.07.010","journal-title":"Gastrointest Endosc"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1055\/a-2350-1930","article-title":"Influence of specialization on primary success and complication rate in ERCP. Proposal to improve the quality of ERCP","volume":"62","author":"Leifeld L","year":"2024","unstructured":"Leifeld L, Jakobs R, Frieling T, et al.. Influence of specialization on primary success and complication rate in ERCP. Proposal to improve the quality of ERCP. Z Gastroenterol. 2024, 62:1224-8. 10.1055\/a-2350-1930","journal-title":"Z Gastroenterol"},{"key":"ref5","article-title":"Biliary stent migration with duodenal perforation","volume":"40","author":"Yaprak M","year":"2008","unstructured":"Yaprak M, Mesci A, Colak T, et al.. Biliary stent migration with duodenal perforation. Eurasian J Med. 2008, 40:154-6.","journal-title":"Eurasian J Med"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1007\/s00464-008-0067-x","article-title":"Migration of biliary plastic stents: experience of a tertiary center","volume":"23","author":"Arhan M","year":"2009","unstructured":"Arhan M, Odemi\u015f B, Parlak E, Ertu\u011frul I, Ba\u015far O. Migration of biliary plastic stents: experience of a tertiary center. Surg Endosc. 2009, 23:769-75. 10.1007\/s00464-008-0067-x","journal-title":"Surg Endosc"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1007\/s10620-022-07461-4","article-title":"Distal biliary stent migration in patients with irretrievable bile duct stones: long-term comparison between straight and double-pigtail stents","volume":"67","author":"Paspatis GA","year":"2022","unstructured":"Paspatis GA, Papastergiou V, Mpitouli A, et al.. Distal biliary stent migration in patients with irretrievable bile duct stones: long-term comparison between straight and double-pigtail stents. Dig Dis Sci. 2022, 67:4557-64. 10.1007\/s10620-022-07461-4","journal-title":"Dig Dis Sci"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1016\/s0016-5107(92)70429-5","article-title":"Incidence and risk factors for biliary and pancreatic stent migration","volume":"38","author":"Johanson JF","year":"1992","unstructured":"Johanson JF, Schmalz MJ, Geenen JE. Incidence and risk factors for biliary and pancreatic stent migration. Gastrointest Endosc. 1992, 38:341-6. 10.1016\/s0016-5107(92)70429-5","journal-title":"Gastrointest Endosc"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.1097\/MCG.0000000000002029","article-title":"Bowel perforation caused by biliary stent migration after ERCP: a systematic review","author":"Wilson N","year":"2024","unstructured":"Wilson N, Ezeani C, Ismail A, et al.. Bowel perforation caused by biliary stent migration after ERCP: a systematic review. J Clin Gastroenterol. 2024, 10.1097\/MCG.0000000000002029","journal-title":"J Clin Gastroenterol"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.1093\/jscr\/rjad109","article-title":"Migratory biliary stent resulting in colonic perforation: a rare complication and review of literature","volume":"2023","author":"Wilson Z","year":"2023","unstructured":"Wilson Z, Diab J, Putnis S. Migratory biliary stent resulting in colonic perforation: a rare complication and review of literature. J Surg Case Rep. 2023, 2023:rjad109. 10.1093\/jscr\/rjad109","journal-title":"J Surg Case Rep"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijscr.2025.110921","article-title":"Distal sigmoid perforation secondary to migration of a biliary stent: a case report","volume":"128","author":"Asghari Y","year":"2025","unstructured":"Asghari Y, Firuzpour F. Distal sigmoid perforation secondary to migration of a biliary stent: a case report. Int J Surg Case Rep. 2025, 128:110921. 10.1016\/j.ijscr.2025.110921","journal-title":"Int J Surg Case Rep"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1258\/RSMSMJ.55.1.57I","article-title":"Colonic perforation secondary to migrated biliary stent. Case report of an unusual complication, and literature review","volume":"55","author":"Hunter K","year":"2010","unstructured":"Hunter K, Siddiqui T, Komolafe Oo, Chong DCS. Colonic perforation secondary to migrated biliary stent. Case report of an unusual complication, and literature review. Scottish Med J. 2010, 55:1-6. 10.1258\/RSMSMJ.55.1.57I","journal-title":"Scottish Med J"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.4067\/S0718-40262013000400011","article-title":"Perforaci\u00f3n diverticular sigmoidea secundaria a la migraci\u00f3n de endopr\u00f3tesis biliar pl\u00e1stica","volume":"65","author":"de Andr\u00e9s A B","year":"2013","unstructured":"de Andr\u00e9s A B, Francisca Moreno R, Patricia Legido M, Jos\u00e9 Rabad\u00e1n J, Juan Beltr\u00e1n de Heredia R. Perforaci\u00f3n diverticular sigmoidea secundaria a la migraci\u00f3n de endopr\u00f3tesis biliar pl\u00e1stica. Rev Chil Cir (online). 2013, 65:346-50. 10.4067\/S0718-40262013000400011","journal-title":"Rev Chil Cir (online)"},{"key":"ref14","article-title":"A potentially fatal complication of biliary stent migration","volume":"4","author":"Warnock JM","year":"2013","unstructured":"Warnock JM, Thompson RJ. A potentially fatal complication of biliary stent migration. J Med Cases. 2013, 4:49-51.","journal-title":"J Med Cases"},{"key":"ref15","doi-asserted-by":"publisher","DOI":"10.25121\/PNM.2018.31.2A.42","article-title":"Migrated plastic biliary stent causing colon perforation: analysis of emergency admission and literature review","volume":"30","author":"Hogendorf P","year":"2018","unstructured":"Hogendorf P, Skulimowski A, Durczy\u0144ski A, Strzelczyk J. Migrated plastic biliary stent causing colon perforation: analysis of emergency admission and literature review. Post N Med. 2018, 30:42-6. 10.25121\/PNM.2018.31.2A.42","journal-title":"Post N Med"},{"key":"ref16","doi-asserted-by":"publisher","DOI":"10.36347\/sasjs.2021.v07i11.004","article-title":"Cecal perforation secondary to migrated stent mimicking perforated appendicitis","volume":"11","author":"Ong \u00a0X","year":"2021","unstructured":"Ong \u00a0X, Leow \u00a0Y. Cecal perforation secondary to migrated stent mimicking perforated appendicitis. SAS J Surg \u00a0. 2021, 11:648-9. 10.36347\/sasjs.2021.v07i11.004","journal-title":"SAS J Surg \u00a0"},{"key":"ref17","doi-asserted-by":"publisher","DOI":"10.1016\/s0016-510770342-3","article-title":"Biliary stent migration with colonic diverticular impaction","volume":"38","author":"Ruffolo TA","year":"1992","unstructured":"Ruffolo TA, Lehman GA, Sherman S, Aycock R, Hayes A. Biliary stent migration with colonic diverticular impaction. Gastrointest Endosc. 1992, 38:81-3. 10.1016\/s0016-510770342-3","journal-title":"Gastrointest Endosc"},{"key":"ref18","doi-asserted-by":"publisher","DOI":"10.3348\/kjr.2015.16.2.444","article-title":"Colonic perforations caused by migrated plastic biliary stents","volume":"16","author":"Virgilio E","year":"2015","unstructured":"Virgilio E, Pascarella G, Scandavini CM, Frezza B, Bocchetti T, Balducci G. Colonic perforations caused by migrated plastic biliary stents. Korean J Radiol. 2015, 16:444-5. 10.3348\/kjr.2015.16.2.444","journal-title":"Korean J Radiol"},{"key":"ref19","doi-asserted-by":"publisher","DOI":"10.1002\/cl2.1230","article-title":"PRISMA2020: An R package and Shiny app for producing PRISMA 2020-compliant flow diagrams, with interactivity for optimised digital transparency and Open Synthesis","volume":"18","author":"Haddaway NR","year":"2022","unstructured":"Haddaway NR, Page MJ, Pritchard CC, McGuinness LA. PRISMA2020: An R package and Shiny app for producing PRISMA 2020-compliant flow diagrams, with interactivity for optimised digital transparency and Open Synthesis. Campbell Syst Rev. 2022, 18:e1230. 10.1002\/cl2.1230","journal-title":"Campbell Syst Rev"},{"key":"ref20","doi-asserted-by":"publisher","DOI":"10.1259\/0007-1285-67-804-1270","article-title":"Intestinal perforation\u2014an unusual complication of endoscopic biliary stenting","volume":"67","author":"D'Costa H","year":"1994","unstructured":"D'Costa H, Toy E, Dennis MJ, Brown C. Intestinal perforation\u2014an unusual complication of endoscopic biliary stenting. Br J Radiol. 1994, 67:1270-1. 10.1259\/0007-1285-67-804-1270","journal-title":"Br J Radiol"},{"key":"ref21","doi-asserted-by":"publisher","DOI":"10.1055\/s-2007-1005523","article-title":"Sigmoid perforation: a rare complication of a migrated biliary endoprosthesis","volume":"28","author":"Schaafsma RJ","year":"1996","unstructured":"Schaafsma RJ, Spoelstra P, Pakan J, Huibregtse K. Sigmoid perforation: a rare complication of a migrated biliary endoprosthesis. Endoscopy. 1996, 28:469-70. 10.1055\/s-2007-1005523","journal-title":"Endoscopy"},{"key":"ref22","doi-asserted-by":"publisher","DOI":"10.1055\/s-2007-1005606","article-title":"Sigmoid diverticular perforation relating to the migration of a polyethylene endoprosthesis","volume":"28","author":"Baty V","year":"1996","unstructured":"Baty V, Denis B, Bigard MA, Gaucher P. Sigmoid diverticular perforation relating to the migration of a polyethylene endoprosthesis. Endoscopy. 1996, 28:781. 10.1055\/s-2007-1005606","journal-title":"Endoscopy"},{"key":"ref23","doi-asserted-by":"publisher","DOI":"10.1016\/s0016-5107(98)70262-7","article-title":"Biliary stent migration with colonic diverticular perforation","volume":"47","author":"Lenzo NP","year":"1998","unstructured":"Lenzo NP, Garas G. Biliary stent migration with colonic diverticular perforation. Gastrointest Endosc. 1998, 47:543-4. 10.1016\/s0016-5107(98)70262-7","journal-title":"Gastrointest Endosc"},{"key":"ref24","doi-asserted-by":"publisher","DOI":"10.1016\/s0016-5107(98)70137-3","article-title":"Duodenal-colic fistula resulting from migration of a biliary stent: a case report","volume":"48","author":"Ang BK","year":"1998","unstructured":"Ang BK, Wee SB, Kaushik SP, Low CH. Duodenal-colic fistula resulting from migration of a biliary stent: a case report. Gastrointest Endosc. 1998, 48:80-3. 10.1016\/s0016-5107(98)70137-3","journal-title":"Gastrointest Endosc"},{"key":"ref25","doi-asserted-by":"publisher","DOI":"10.1055\/s-2000-87","article-title":"Gut perforation caused by biliary endoprosthesis","volume":"32","author":"St\u00f8rkson RH","year":"2000","unstructured":"St\u00f8rkson RH, Edwin B, Reiertsen O, Faerden AE, Sortland O, Rosseland AR. Gut perforation caused by biliary endoprosthesis. Endoscopy. 2000, 32:87-9. 10.1055\/s-2000-87","journal-title":"Endoscopy"},{"key":"ref26","doi-asserted-by":"publisher","DOI":"10.1097\/00042737-200110000-00021","article-title":"Colocutaneous fistula relating to the migration of a biliary stent","volume":"13","author":"Figueiras RG","year":"2001","unstructured":"Figueiras RG, Echart MO, Figueiras AG, Gonz\u00e1lez GP. Colocutaneous fistula relating to the migration of a biliary stent. Eur J Gastroenterol Hepatol. 2001, 13:1251-3. 10.1097\/00042737-200110000-00021","journal-title":"Eur J Gastroenterol Hepatol"},{"key":"ref27","doi-asserted-by":"publisher","DOI":"10.1055\/s-2001-18306","article-title":"Migration of a biliary Tannenbaum stent with perforation of sigmoid diverticulum (German)","volume":"173","author":"Klein U","year":"2001","unstructured":"Klein U, Weiss F, Wittkugel O. Migration of a biliary Tannenbaum stent with perforation of sigmoid diverticulum (German). Rofo. 2001, 173:1057. 10.1055\/s-2001-18306","journal-title":"Rofo"},{"key":"ref28","doi-asserted-by":"publisher","DOI":"10.1067\/mge.2003.71","article-title":"Complex colovesicular fistula: a severe complication caused by biliary stent migration","volume":"57","author":"Wilhelm A","year":"2003","unstructured":"Wilhelm A, Langer C, Zoeller G, Nustede R, Becker H. Complex colovesicular fistula: a severe complication caused by biliary stent migration. Gastrointest Endosc. 2003, 57:124-6. 10.1067\/mge.2003.71","journal-title":"Gastrointest Endosc"},{"key":"ref29","doi-asserted-by":"publisher","DOI":"10.1046\/j.1445-2197.2003.02698.x","article-title":"Sigmoid colon perforation following a migrated biliary stent","volume":"73","author":"Elliott M","year":"2003","unstructured":"Elliott M, Boland S. Sigmoid colon perforation following a migrated biliary stent. ANZ J Surg. 2003, 73:669-70. 10.1046\/j.1445-2197.2003.02698.x","journal-title":"ANZ J Surg"},{"key":"ref30","doi-asserted-by":"publisher","DOI":"10.1007\/s00464-002-9163-5","article-title":"Stent migration necessitating surgical intervention","volume":"17","author":"Diller R","year":"2003","unstructured":"Diller R, Senninger N, Kautz G, T\u00fcbergen D. Stent migration necessitating surgical intervention. Surg Endosc. 2003, 17:1803-7. 10.1007\/s00464-002-9163-5","journal-title":"Surg Endosc"},{"key":"ref31","article-title":"Biliary stent causing colovaginal fistula: case report","volume":"8","author":"Blake AM","year":"2004","unstructured":"Blake AM, Monga N, Dunn EM. Biliary stent causing colovaginal fistula: case report. JSLS. 2004, 8:73-5.","journal-title":"JSLS"},{"key":"ref32","article-title":"F\u00edstula colovesical secundaria a la migraci\u00f3n de una endopr\u00f3tesis biliar. Reporte de un caso","volume":"74","author":"Soto-\u00c1vila JJ","year":"2006","unstructured":"Soto-\u00c1vila JJ, G\u00f3mez-Wong ME, Preciado-Hern\u00e1ndez F. F\u00edstula colovesical secundaria a la migraci\u00f3n de una endopr\u00f3tesis biliar. Reporte de un caso. Cir Cir. 2006, 74:473-5.","journal-title":"Cir Cir"},{"key":"ref33","doi-asserted-by":"publisher","DOI":"10.1007\/s00261-006-9067-2","article-title":"Sigmoid colonic perforation and pelvic abscess complicating biliary stent migration","volume":"32","author":"Anderson EM","year":"2007","unstructured":"Anderson EM, Phillips-Hughes J, Chapman R. Sigmoid colonic perforation and pelvic abscess complicating biliary stent migration. Abdom Imaging. 2007, 32:317-9. 10.1007\/s00261-006-9067-2","journal-title":"Abdom Imaging"},{"key":"ref34","doi-asserted-by":"publisher","DOI":"10.3748\/wjg.v13.i40.5397","article-title":"Complications and treatment of migrated biliary endoprostheses: a review of the literature","volume":"13","author":"Namdar T","year":"2007","unstructured":"Namdar T, Raffel AM, Topp SA, et al.. Complications and treatment of migrated biliary endoprostheses: a review of the literature. World J Gastroenterol. 2007, 13:5397-9. 10.3748\/wjg.v13.i40.5397","journal-title":"World J Gastroenterol"},{"key":"ref35","doi-asserted-by":"crossref","DOI":"10.1080\/00015458.2008.11680191","article-title":"Double sigmoid colon perforation by a migrated biliary stent","volume":"108","author":"Belyaev O","year":"2008","unstructured":"Belyaev O, M\u00fcller CA, Uhl W. Double sigmoid colon perforation by a migrated biliary stent. Acta Chirurgica Belgica. 2008, 108:125-6.","journal-title":"Acta Chirurgica Belgica"},{"key":"ref36","doi-asserted-by":"crossref","DOI":"10.1055\/s-2007-967056","article-title":"A case of colonic perforation from biliary stent","volume":"40","author":"Aryal KR","year":"2008","unstructured":"Aryal KR, Sherlock DJ. A case of colonic perforation from biliary stent. Endoscopy. 2008, 40:54-10.","journal-title":"Endoscopy"},{"key":"ref37","doi-asserted-by":"publisher","DOI":"10.1308\/147870810X12659688852239","article-title":"A review of problems following insertion of biliary stents illustrated by an unusual complication","volume":"92","author":"Bagul A","year":"2010","unstructured":"Bagul A, Pollard C, Dennison AR. A review of problems following insertion of biliary stents illustrated by an unusual complication. Ann R Coll Surg Engl. 2010, 92:W27-31. 10.1308\/147870810X12659688852239","journal-title":"Ann R Coll Surg Engl"},{"key":"ref38","article-title":"Enterovesicale fistel door gemigreerde galwegstent (Dutch)","volume":"155","author":"Wagemakers S","year":"2011","unstructured":"Wagemakers S, Ibelings M. Enterovesicale fistel door gemigreerde galwegstent (Dutch). Ned Tijdschr Geneeskd. 2011, 155:3615.","journal-title":"Ned Tijdschr Geneeskd"},{"key":"ref39","doi-asserted-by":"publisher","DOI":"10.1093\/jscr\/2011.3.6","article-title":"Biliary stent migration presenting as transdiverticular sigmoid perforation","volume":"2011","author":"Peter A","year":"2011","unstructured":"Peter A, Walker M, Shinil K, et al.. Biliary stent migration presenting as transdiverticular sigmoid perforation. J Surg Case Rep. 2011, 2011:6. 10.1093\/jscr\/2011.3.6","journal-title":"J Surg Case Rep"},{"key":"ref40","doi-asserted-by":"publisher","DOI":"10.1136\/bcr.04.2011.4078","article-title":"Endoscopic management of migrated biliary stent causing sigmoid perforation","volume":"2011","author":"Jafferbhoy SF","year":"2011","unstructured":"Jafferbhoy SF, Scriven P, Bannister J, Shiwani MH, Hurlstone P. Endoscopic management of migrated biliary stent causing sigmoid perforation. BMJ Case Rep. 2011, 2011:10.1136\/bcr.04.2011.4078","journal-title":"BMJ Case Rep"},{"key":"ref41","doi-asserted-by":"publisher","DOI":"10.1016\/j.gie.2011.06.011","article-title":"Biliary stent migration with colonic perforation: a very rare complication and the lesson that should be learned from it","volume":"74","author":"Lankisch TO","year":"2011","unstructured":"Lankisch TO, Alten TA, Lehner F, Knitsch W. Biliary stent migration with colonic perforation: a very rare complication and the lesson that should be learned from it. Gastrointest Endosc. 2011, 74:924-5; discussion 925. 10.1016\/j.gie.2011.06.011","journal-title":"Gastrointest Endosc"},{"key":"ref42","doi-asserted-by":"publisher","DOI":"10.1016\/j.jviscsurg.2011.09.011","article-title":"Double Sigmoid colon perforation due to migration of a biliary stent","volume":"148","author":"Malgras B","year":"2011","unstructured":"Malgras B, Pierret C, Tourtier JP, Olagui G, Nizou C, Duverger V. Double Sigmoid colon perforation due to migration of a biliary stent. J Visc Surg. 2011, 148:e397-9. 10.1016\/j.jviscsurg.2011.09.011","journal-title":"J Visc Surg"},{"key":"ref43","doi-asserted-by":"publisher","DOI":"10.1055\/s-0032-1309719","article-title":"Sigmoid perforation caused by a migrated biliary stent and closed with clips","volume":"44 Suppl 2 UCTN","author":"Alcaide N","year":"2012","unstructured":"Alcaide N, Lorenzo-Pelayo S, Herranz-Bachiller MT, de la Serna-Higuera C, Barrio J, Perez-Miranda M. Sigmoid perforation caused by a migrated biliary stent and closed with clips. Endoscopy. 2012, 44 Suppl 2 UCTN:E274. 10.1055\/s-0032-1309719","journal-title":"Endoscopy"},{"key":"ref44","doi-asserted-by":"publisher","DOI":"10.1007\/s12262-012-0663-9","article-title":"Migrated biliary stent presenting as a sigmoid diverticulitis-case report","volume":"75","author":"Kittappa K","year":"2013","unstructured":"Kittappa K, Maruthachalam K, Brookstein R, Debrah S. Migrated biliary stent presenting as a sigmoid diverticulitis-case report. Indian J Surg. 2013, 75:253-4. 10.1007\/s12262-012-0663-9","journal-title":"Indian J Surg"},{"key":"ref45","doi-asserted-by":"publisher","DOI":"10.1136\/bcr-2013-009124","article-title":"Biliary stent migration causing perforation of the caecum and chronic abdominal pain","volume":"2013","author":"Jones M","year":"2013","unstructured":"Jones M, George B, Jameson J, Garcea G. Biliary stent migration causing perforation of the caecum and chronic abdominal pain. BMJ Case Rep. 2013, 2013:10.1136\/bcr-2013-009124","journal-title":"BMJ Case Rep"},{"key":"ref46","article-title":"Cecum perforation due to biliary stent migration","volume":"35 (7)","author":"Barut I","year":"2014","unstructured":"Barut I, Tarhan OR. Cecum perforation due to biliary stent migration. Saudi Med J. 2014, 35 (7):747-9.","journal-title":"Saudi Med J"},{"key":"ref47","doi-asserted-by":"publisher","DOI":"10.1093\/jscr\/rju134","article-title":"Migrated biliary plastic stent causing double sigmoid colon perforation","volume":"2014","author":"Konstantinidis C","year":"2014","unstructured":"Konstantinidis C, Varsos P, Kympouris S, Volteas S. Migrated biliary plastic stent causing double sigmoid colon perforation. J Surg Case Rep. 2014, 2014:rju134. 10.1093\/jscr\/rju134","journal-title":"J Surg Case Rep"},{"key":"ref48","doi-asserted-by":"publisher","DOI":"10.1136\/bcr-2014-206805","article-title":"Migrated biliary stent causing perforation of sigmoid colon and pelvic abscess","volume":"2015","author":"Mady RF","year":"2015","unstructured":"Mady RF, Niaz OS, Assal MM. Migrated biliary stent causing perforation of sigmoid colon and pelvic abscess. BMJ Case Rep. 2015, 2015:10.1136\/bcr-2014-206805","journal-title":"BMJ Case Rep"},{"key":"ref49","doi-asserted-by":"publisher","DOI":"10.1111\/ans.12796","article-title":"Remove the migrated stent: sigmoid colon perforation from migrated biliary stent","volume":"86","author":"Chittleborough TJ","year":"2016","unstructured":"Chittleborough TJ, Mgaieth S, Kirkby B, Zakon J. Remove the migrated stent: sigmoid colon perforation from migrated biliary stent. ANZ J Surg. 2016, 86:947-8. 10.1111\/ans.12796","journal-title":"ANZ J Surg"},{"key":"ref50","doi-asserted-by":"publisher","DOI":"10.1038\/ajg.2016.414","article-title":"Colonic perforation secondary to retained biliary stent","volume":"112","author":"Chou ND","year":"2017","unstructured":"Chou ND, Burbridge RA, Jowell PS. Colonic perforation secondary to retained biliary stent. Am J Gastroenterol. 2017, 112:13. 10.1038\/ajg.2016.414","journal-title":"Am J Gastroenterol"},{"key":"ref51","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijscr.2017.01.016","article-title":"A rare cause for Hartmann's procedure due to biliary stent migration: a case report","volume":"31","author":"Siaperas P","year":"2017","unstructured":"Siaperas P, Ioannidis A, Skarpas A, Angelopoulos A, Drikos I, Karanikas I. A rare cause for Hartmann's procedure due to biliary stent migration: a case report. Int J Surg Case Rep. 2017, 31:83-5. 10.1016\/j.ijscr.2017.01.016","journal-title":"Int J Surg Case Rep"},{"key":"ref52","doi-asserted-by":"publisher","DOI":"10.1155\/2019\/2549170","article-title":"Sigmoid diverticulitis and perforation secondary to biliary stent migration","volume":"2019","author":"Riccardi M","year":"2019","unstructured":"Riccardi M, Deters K, Jabbar F. Sigmoid diverticulitis and perforation secondary to biliary stent migration. Case Rep Surg. 2019, 2019:2549170. 10.1155\/2019\/2549170","journal-title":"Case Rep Surg"},{"key":"ref53","doi-asserted-by":"publisher","DOI":"10.1055\/a-0889-7085","article-title":"Removal of a migrated biliary stent perforating the colonic wall: a case description of endoscopic repair","volume":"51","author":"Hnaris K","year":"2019","unstructured":"Hnaris K, Bechara R. Removal of a migrated biliary stent perforating the colonic wall: a case description of endoscopic repair. Endoscopy. 2019, 51:E282-3. 10.1055\/a-0889-7085","journal-title":"Endoscopy"},{"key":"ref54","doi-asserted-by":"publisher","DOI":"10.1159\/000503076","article-title":"Sigmoid perforation by a migrated plastic biliary stent","volume":"27","author":"Marcos P","year":"2020","unstructured":"Marcos P, Capel\u00e3o G, Atalaia-Martins C, Clara P, Eliseu L, Vasconcelos H. Sigmoid perforation by a migrated plastic biliary stent. GE Port J Gastroenterol. 2020, 27:215-8. 10.1159\/000503076","journal-title":"GE Port J Gastroenterol"},{"key":"ref55","doi-asserted-by":"publisher","DOI":"10.1007\/s00384-020-03728-2","article-title":"Sigmoid colon perforation caused by migrated plastic biliary stents: a case report","volume":"36","author":"Tao Y","year":"2021","unstructured":"Tao Y, Long J. Sigmoid colon perforation caused by migrated plastic biliary stents: a case report. Int J Colorectal Dis. 2021, 36:199-201. 10.1007\/s00384-020-03728-2","journal-title":"Int J Colorectal Dis"},{"key":"ref56","doi-asserted-by":"publisher","DOI":"10.3892\/mco.2021.2298","article-title":"Appendiceal perforation due to biliary stent migration in a neutropenic patient with lung cancer receiving chemotherapy: a case report","volume":"15","author":"Pengerm\u00e4 P","year":"2021","unstructured":"Pengerm\u00e4 P, Katunin J, Turunen A, Sileri P, Giarratano G, Palom\u00e4ki A, Kechagias A. Appendiceal perforation due to biliary stent migration in a neutropenic patient with lung cancer receiving chemotherapy: a case report. Mol Clin Oncol. 2021, 15:136. 10.3892\/mco.2021.2298","journal-title":"Mol Clin Oncol"},{"key":"ref57","doi-asserted-by":"publisher","DOI":"10.1097\/MD.0000000000028392","article-title":"Colonic diverticular perforation by a migrated biliary stent: a case report with literature review","volume":"100","author":"Park TY","year":"2021","unstructured":"Park TY, Hong SW, Oh HC, Do JH. Colonic diverticular perforation by a migrated biliary stent: a case report with literature review. Medicine (Baltimore). 2021, 100:e28392. 10.1097\/MD.0000000000028392","journal-title":"Medicine (Baltimore)"},{"key":"ref58","doi-asserted-by":"publisher","DOI":"10.1007\/s12328-021-01544-x","article-title":"Successful endoscopic closure with an over-the-scope clip for sigmoid colon perforation due to bile duct stent migration","volume":"15","author":"Yamaguchi D","year":"2022","unstructured":"Yamaguchi D, Nagatsuma G, Jinnouchi A, et al.. Successful endoscopic closure with an over-the-scope clip for sigmoid colon perforation due to bile duct stent migration. Clin J Gastroenterol. 2022, 15:157-63. 10.1007\/s12328-021-01544-x","journal-title":"Clin J Gastroenterol"},{"key":"ref59","doi-asserted-by":"publisher","DOI":"10.1093\/jscr\/rjac404","article-title":"Minimally invasive management of an ascending colonic perforation secondary to distal biliary stent migration: a multidisciplinary, novel laparoendoscopic approach","volume":"2022","author":"Kodia K","year":"2022","unstructured":"Kodia K, Huerta CT, Arora Y, Wickham C, Deshpande AR, Paluvoi N. Minimally invasive management of an ascending colonic perforation secondary to distal biliary stent migration: a multidisciplinary, novel laparoendoscopic approach. J Surg Case Rep. 2022, 2022:rjac404. 10.1093\/jscr\/rjac404","journal-title":"J Surg Case Rep"},{"key":"ref60","doi-asserted-by":"publisher","DOI":"10.14309\/crj.0000000000000972","article-title":"Successful nonoperative management of a sigmoid colon perforation caused by a migrated biliary stent","volume":"10","author":"Kwong E","year":"2023","unstructured":"Kwong E, Jones K, Park S, Kwok K. Successful nonoperative management of a sigmoid colon perforation caused by a migrated biliary stent. ACG Case Rep J. 2023, 10:e00972. 10.14309\/crj.0000000000000972","journal-title":"ACG Case Rep J"},{"key":"ref61","doi-asserted-by":"publisher","DOI":"10.14309\/crj.0000000000001019","article-title":"The pierced colon: when biliary stents go the wrong way","volume":"10","author":"Rybinski F","year":"2023","unstructured":"Rybinski F, Heinrich H, Zimmerli M, Kahl S. The pierced colon: when biliary stents go the wrong way. ACG Case Rep J. 2023, 10:e01019. 10.14309\/crj.0000000000001019","journal-title":"ACG Case Rep J"},{"key":"ref62","doi-asserted-by":"publisher","DOI":"10.1155\/2023\/9493333","article-title":"Cecal perforation induced by migrated biliary stent as a rare complication of ERCP: a case report and literature review","volume":"2023","author":"Mohammadi Tofigh A","year":"2023","unstructured":"Mohammadi Tofigh A, Tahmasbi H, Iranshahi M, Haghbin Toutounchi A, Khoshnoudi H, Kouchak Hosseini SP. Cecal perforation induced by migrated biliary stent as a rare complication of ERCP: a case report and literature review. Case Rep Surg. 2023, 2023:9493333. 10.1155\/2023\/9493333","journal-title":"Case Rep Surg"},{"key":"ref63","doi-asserted-by":"publisher","DOI":"10.17235\/reed.2023.9673\/2023","article-title":"Endoscopic rescue of a fistulizing biliary plastic stent","volume":"115","author":"Berdugo Hurtado F","year":"2023","unstructured":"Berdugo Hurtado F, Ortiz S\u00e1nchez A, Z\u00fa\u00f1iga de Mora Figueroa B, Barrientos Delgado A. Endoscopic rescue of a fistulizing biliary plastic stent. Rev Esp Enferm Dig. 2023, 115:736-7. 10.17235\/reed.2023.9673\/2023","journal-title":"Rev Esp Enferm Dig"},{"key":"ref64","doi-asserted-by":"publisher","DOI":"10.12659\/AJCR.943020","article-title":"Endoscopic treatment of duodenocolic fistula caused by migrating biliary stents","volume":"25","author":"He Y","year":"2024","unstructured":"He Y, Ye R, Xie Y, Deng X, Zhang L. Endoscopic treatment of duodenocolic fistula caused by migrating biliary stents. Am J Case Rep. 2024, 25:e943020. 10.12659\/AJCR.943020","journal-title":"Am J Case Rep"},{"key":"ref65","doi-asserted-by":"publisher","DOI":"10.17235\/reed.2023.9696\/2023","article-title":"Plastic biliary stent migration as a cause of ascending colon perforation","volume":"116","author":"Vergara-Fern\u00e1ndez O","year":"2024","unstructured":"Vergara-Fern\u00e1ndez O, Tueme de la Pe\u00f1a D, Canto-Losa J. Plastic biliary stent migration as a cause of ascending colon perforation. Rev Esp Enferm Dig. 2024, 116:283-4. 10.17235\/reed.2023.9696\/2023","journal-title":"Rev Esp Enferm Dig"},{"key":"ref66","doi-asserted-by":"publisher","DOI":"10.14309\/crj.0000000000001424","article-title":"Migrated plastic biliary stent causing cecal perforation","volume":"11","author":"Swied MY","year":"2024","unstructured":"Swied MY, Al Turk Y, Maitar M. Migrated plastic biliary stent causing cecal perforation. ACG Case Rep J. 2024, 11:e01424. 10.14309\/crj.0000000000001424","journal-title":"ACG Case Rep J"},{"key":"ref67","doi-asserted-by":"publisher","DOI":"10.1093\/jscr\/rjae737","article-title":"Case report: migratory biliary stent resulting in sigmoid colon perforation","volume":"2024","author":"Beloy JB","year":"2024","unstructured":"Beloy JB, Lund NP, Van Hell AM, Allamaneni S. Case report: migratory biliary stent resulting in sigmoid colon perforation. J Surg Case Rep. 2024, 2024:rjae737. 10.1093\/jscr\/rjae737","journal-title":"J Surg Case Rep"}],"container-title":["Cureus"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cureus.com\/articles\/337998-conservative-treatment-of-sigmoid-diverticulum-perforation-secondary-to-migrated-biliary-plastic-prostheses-inserted-by-endoscopic-retrograde-cholangiopancreatography-a-case-report-of-an-unusual-adverse-event-and-literature-review","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,2,15]],"date-time":"2025-02-15T12:01:40Z","timestamp":1739620900000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cureus.com\/articles\/337998-conservative-treatment-of-sigmoid-diverticulum-perforation-secondary-to-migrated-biliary-plastic-prostheses-inserted-by-endoscopic-retrograde-cholangiopancreatography-a-case-report-of-an-unusual-adverse-event-and-literature-review"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,2,15]]},"references-count":67,"URL":"https:\/\/doi.org\/10.7759\/cureus.79042","relation":{},"ISSN":["2168-8184"],"issn-type":[{"value":"2168-8184","type":"print"}],"subject":[],"published":{"date-parts":[[2025,2,15]]}}}