{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,24]],"date-time":"2026-04-24T01:20:57Z","timestamp":1776993657580,"version":"3.51.4"},"reference-count":15,"publisher":"Springer Science and Business Media LLC","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2025,4,30]]},"DOI":"10.7759\/cureus.83232","type":"journal-article","created":{"date-parts":[[2025,4,30]],"date-time":"2025-04-30T07:55:42Z","timestamp":1745999742000},"source":"Crossref","is-referenced-by-count":1,"title":["Development and Validation of Radiographic Measurement Templates for Standardized X-ray Analysis"],"prefix":"10.7759","author":[{"given":"Alqasim","family":"Elnaggar","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"David","family":"Allen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"David","family":"Abdelnour","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Magd","family":"Boutany","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ahmad","family":"Almaat","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Andrew","family":"Knapp","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Cameron J","family":"Hoard","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rahul","family":"Vaidya","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.92B1.22257","article-title":"A comparison of four systems for calibration when templating for total hip replacement with digital radiography","volume":"92","author":"Franken M","year":"2010","unstructured":"Franken M, Grimm B, Heyligers I. A comparison of four systems for calibration when templating for total hip replacement with digital radiography. J Bone Joint Surg Br. 2010, 92:136-41. 10.1302\/0301-620X.92B1.22257","journal-title":"J Bone Joint Surg Br"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.7759\/cureus.37108","article-title":"Acute correction of femoral malrotation after intramedullary nailing using an intraoperative digital protractor","volume":"15","author":"Goethals J","year":"2023","unstructured":"Goethals J, Cavazos DR, Denisiuk M, Bray R, Nasr K, Vaidya R. Acute correction of femoral malrotation after intramedullary nailing using an intraoperative digital protractor. Cureus. 2023, 15:e37108. 10.7759\/cureus.37108","journal-title":"Cureus"},{"key":"ref3","unstructured":"Bonesetter app. (2025). Accessed. April 30, 2025: https:\/\/detroitbonesetter.com\/."},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1016\/j.artd.2023.101182","article-title":"Free hip arthroplasty templating software - does it work?","volume":"23","author":"Jouflas AC","year":"2023","unstructured":"Jouflas AC, Gilani SF, Nadar AC, Whitaker J, Carlson JB. Free hip arthroplasty templating software - does it work?. Arthroplast Today. 2023, 23:101182. 10.1016\/j.artd.2023.101182","journal-title":"Arthroplast Today"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.3390\/medicina58081079","article-title":"Online instruction to measure axial alignment with the Bonesetter app","volume":"58","author":"Bernstein M","year":"2022","unstructured":"Bernstein M, Bunge T, Rosinski K, Kfuri M, Crist B, Knapp A, Vaidya R. Online instruction to measure axial alignment with the Bonesetter app. Medicina (Kaunas). 2022, 58:1079. 10.3390\/medicina58081079","journal-title":"Medicina (Kaunas)"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2007.11.019","article-title":"A comparison of acetate vs digital templating for preoperative planning of total hip arthroplasty: is digital templating accurate and safe?","volume":"24","author":"Iorio R","year":"2009","unstructured":"Iorio R, Siegel J, Specht LM, Tilzey JF, Hartman A, Healy WL. A comparison of acetate vs digital templating for preoperative planning of total hip arthroplasty: is digital templating accurate and safe?. J Arthroplasty. 2009, 24:175-9. 10.1016\/j.arth.2007.11.019","journal-title":"J Arthroplasty"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.29245\/2767-5130\/2020\/3.1119","article-title":"A more accurate method to determine the magnification of radiographs when templating for hip arthroplasty?","volume":"1","author":"Magill H","year":"2020","unstructured":"Magill H, Ibrahim M, Mohamed F, Grant S, Rudran B, Radford W. A more accurate method to determine the magnification of radiographs when templating for hip arthroplasty?. J Orthopedics &amp; Orthopedic Surg. 2020, 1:11-4. 10.29245\/2767-5130\/2020\/3.1119","journal-title":"J Orthopedics & Orthopedic Surg"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1302\/2058-5241.6.210048","article-title":"The accuracy and reliability of preoperative digital 2D templating in prosthesis size prediction in uncemented versus cemented total hip arthroplasty: a systematic review and meta-analysis","volume":"6","author":"Smith JB","year":"2021","unstructured":"Smith JB, Bishi H, Wang C, Asopa V, Field RE, Sochart DH. The accuracy and reliability of preoperative digital 2D templating in prosthesis size prediction in uncemented versus cemented total hip arthroplasty: a systematic review and meta-analysis. EFORT Open Rev. 2021, 6:1020-39. 10.1302\/2058-5241.6.210048","journal-title":"EFORT Open Rev"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0188743","article-title":"Magnification of digital hip radiographs differs between clinical workplaces","volume":"12","author":"Hornov\u00e1 J","year":"2017","unstructured":"Hornov\u00e1 J, R\u016f\u017ei\u010dka P, Hrubina M, et al.. Magnification of digital hip radiographs differs between clinical workplaces. PLoS One. 2017, 12:e0188743. 10.1371\/journal.pone.0188743","journal-title":"PLoS One"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.7759\/cureus.55735","article-title":"Analyzing the accuracy of digital sizing on long-leg alignment X-rays by using a 1-inch ball bearing: a cheap and effective method","volume":"16","author":"VanAken TD","year":"2024","unstructured":"VanAken TD, Joiner D, Boggs L, Robinson A, Haji N, Vaidya R. Analyzing the accuracy of digital sizing on long-leg alignment X-rays by using a 1-inch ball bearing: a cheap and effective method. Cureus. 2024, 16:e55735. 10.7759\/cureus.55735","journal-title":"Cureus"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1007\/s00068-018-0994-8","article-title":"Digital templating without a calibration marker is accurate at predicting implant size for hip hemiarthroplasty","volume":"46","author":"Derias M","year":"2020","unstructured":"Derias M, Khan MA, Buchanan J. Digital templating without a calibration marker is accurate at predicting implant size for hip hemiarthroplasty. Eur J Trauma Emerg Surg. 2020, 46:115-20. 10.1007\/s00068-018-0994-8","journal-title":"Eur J Trauma Emerg Surg"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.7759\/cureus.62226","article-title":"Radiographic morphometric analysis of the distal radius in the Tamil Nadu population: a retrospective study","volume":"16","author":"Geeta Anasuya D","year":"2024","unstructured":"Geeta Anasuya D, Kumar A, Arasu S, Shanmugam J, Vijaianand M, Praveen D. Radiographic morphometric analysis of the distal radius in the Tamil Nadu population: a retrospective study. Cureus. 2024, 16:e62226. 10.7759\/cureus.62226","journal-title":"Cureus"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620x.84b2.12599","article-title":"A simple guide to determine the magnification of radiographs and to improve the accuracy of preoperative templating","volume":"84","author":"Conn KS","year":"2002","unstructured":"Conn KS, Clarke MT, Hallett JP. A simple guide to determine the magnification of radiographs and to improve the accuracy of preoperative templating. J Bone Joint Surg Br. 2002, 84:269-72. 10.1302\/0301-620x.84b2.12599","journal-title":"J Bone Joint Surg Br"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.90B12.20238","article-title":"Disc calibration for digital templating in hip replacement","volume":"90","author":"Kulkarni A","year":"2008","unstructured":"Kulkarni A, Partington P, Kelly D, Muller S. Disc calibration for digital templating in hip replacement. J Bone Joint Surg Br. 2008, 90:1623-6. 10.1302\/0301-620X.90B12.20238","journal-title":"J Bone Joint Surg Br"},{"key":"ref15","doi-asserted-by":"publisher","DOI":"10.1016\/j.bone.2016.07.018","article-title":"Ethnic differences in bone geometry between White, Black and South Asian men in the UK","volume":"91","author":"Zengin A","year":"2016","unstructured":"Zengin A, Pye SR, Cook MJ, Adams JE, Wu FC, O'Neill TW, Ward KA. Ethnic differences in bone geometry between White, Black and South Asian men in the UK. Bone. 2016, 91:180-5. 10.1016\/j.bone.2016.07.018","journal-title":"Bone"}],"container-title":["Cureus"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cureus.com\/articles\/359374-development-and-validation-of-radiographic-measurement-templates-for-standardized-x-ray-analysis","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,4,30]],"date-time":"2025-04-30T07:55:45Z","timestamp":1745999745000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cureus.com\/articles\/359374-development-and-validation-of-radiographic-measurement-templates-for-standardized-x-ray-analysis"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,4,30]]},"references-count":15,"URL":"https:\/\/doi.org\/10.7759\/cureus.83232","relation":{},"ISSN":["2168-8184"],"issn-type":[{"value":"2168-8184","type":"print"}],"subject":[],"published":{"date-parts":[[2025,4,30]]}}}