{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,5,11]],"date-time":"2025-05-11T04:03:47Z","timestamp":1746936227266,"version":"3.40.5"},"reference-count":20,"publisher":"Springer Science and Business Media LLC","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2025,5,10]]},"DOI":"10.7759\/cureus.83835","type":"journal-article","created":{"date-parts":[[2025,5,10]],"date-time":"2025-05-10T13:35:51Z","timestamp":1746884151000},"source":"Crossref","is-referenced-by-count":0,"title":["Pacemaker Malfunction Triggered by Cybersecurity Activation During Carbon Ion Radiotherapy: A Case Report"],"prefix":"10.7759","author":[{"given":"Eisuke","family":"Horigome","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nobuteru","family":"Kubo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Makoto","family":"Sakai","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hiroshi","family":"Hasegawa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tatsuya","family":"Ohno","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.7150\/ijms.3635","article-title":"Cancer and radiation therapy: current advances and future directions","volume":"9","author":"Baskar R","year":"2012","unstructured":"Baskar R, Lee KA, Yeo R, Yeoh KW. Cancer and radiation therapy: current advances and future directions. Int J Med Sci. 2012, 9:193-9. 10.7150\/ijms.3635","journal-title":"Int J Med Sci"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1002\/cncr.21324","article-title":"The role of radiotherapy in cancer treatment: estimating optimal utilization from a review of evidence-based clinical guidelines","volume":"104","author":"Delaney G","year":"2005","unstructured":"Delaney G, Jacob S, Featherstone C, Barton M. The role of radiotherapy in cancer treatment: estimating optimal utilization from a review of evidence-based clinical guidelines. Cancer. 2005, 104:1129-37. 10.1002\/cncr.21324","journal-title":"Cancer"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1038\/nrclinonc.2009.183","article-title":"Charged particles in radiation oncology","volume":"7","author":"Durante M","year":"2010","unstructured":"Durante M, Loeffler JS. Charged particles in radiation oncology. Nat Rev Clin Oncol. 2010, 7:37-43. 10.1038\/nrclinonc.2009.183","journal-title":"Nat Rev Clin Oncol"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1016\/S1470-2045(14)70412-7","article-title":"Carbon ion radiotherapy in Japan: an assessment of 20 years of clinical experience","volume":"16","author":"Kamada T","year":"2015","unstructured":"Kamada T, Tsujii H, Blakely EA, et al.. Carbon ion radiotherapy in Japan: an assessment of 20 years of clinical experience. Lancet Oncol. 2015, 16:93-100. 10.1016\/S1470-2045(14)70412-7","journal-title":"Lancet Oncol"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1016\/j.jtho.2023.10.016","article-title":"Five-year survival outcomes after carbon-ion radiotherapy for operable Stage I NSCLC: a Japanese national registry study (J-CROS-LUNG)","volume":"19","author":"Kubo N","year":"2024","unstructured":"Kubo N, Suefuji H, Nakajima M, et al.. Five-year survival outcomes after carbon-ion radiotherapy for operable Stage I NSCLC: a Japanese national registry study (J-CROS-LUNG). J Thorac Oncol. 2024, 19:491-9. 10.1016\/j.jtho.2023.10.016","journal-title":"J Thorac Oncol"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1111\/pace.12572","article-title":"Risk of device malfunction in cancer patients with implantable cardiac device undergoing radiotherapy: a population-based cohort study","volume":"38","author":"Zaremba T","year":"2015","unstructured":"Zaremba T, Jakobsen AR, S\u00f8gaard M, Th\u00f8gersen AM, Johansen MB, Madsen LB, Riahi S. Risk of device malfunction in cancer patients with implantable cardiac device undergoing radiotherapy: a population-based cohort study. Pacing Clin Electrophysiol. 2015, 38:343-56. 10.1111\/pace.12572","journal-title":"Pacing Clin Electrophysiol"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2008.01.062","article-title":"Proton beam therapy interference with implanted cardiac pacemakers","volume":"72","author":"Oshiro Y","year":"2008","unstructured":"Oshiro Y, Sugahara S, Noma M, et al.. Proton beam therapy interference with implanted cardiac pacemakers. Int J Radiat Oncol Biol Phys. 2008, 72:723-7. 10.1016\/j.ijrobp.2008.01.062","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2013.07.010","article-title":"Malfunctions of implantable cardiac devices in patients receiving proton beam therapy: incidence and predictors","volume":"87","author":"Gomez DR","year":"2013","unstructured":"Gomez DR, Poenisch F, Pinnix CC, et al.. Malfunctions of implantable cardiac devices in patients receiving proton beam therapy: incidence and predictors. Int J Radiat Oncol Biol Phys. 2013, 87:570-5. 10.1016\/j.ijrobp.2013.07.010","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2015.07.2278","article-title":"Prospective trial of stereotactic body radiation therapy for both operable and inoperable T1N0M0 non-small cell lung cancer: Japan clinical oncology group study JCOG0403","volume":"93","author":"Nagata Y","year":"2015","unstructured":"Nagata Y, Hiraoka M, Shibata T, et al.. Prospective trial of stereotactic body radiation therapy for both operable and inoperable T1N0M0 non-small cell lung cancer: Japan clinical oncology group study JCOG0403. Int J Radiat Oncol Biol Phys. 2015, 93:989-96. 10.1016\/j.ijrobp.2015.07.2278","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.1016\/S1470-2045(21)00401-0","article-title":"Stereotactic ablative radiotherapy for operable stage I non-small-cell lung cancer (revised STARS): long-term results of a single-arm, prospective trial with prespecified comparison to surgery","volume":"22","author":"Chang JY","year":"2021","unstructured":"Chang JY, Mehran RJ, Feng L, et al.. Stereotactic ablative radiotherapy for operable stage I non-small-cell lung cancer (revised STARS): long-term results of a single-arm, prospective trial with prespecified comparison to surgery. Lancet Oncol. 2021, 22:1448-57. 10.1016\/S1470-2045(21)00401-0","journal-title":"Lancet Oncol"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1109\/OJEMB.2024.3358989","article-title":"The contribution of secondary particles following carbon ion radiotherapy to soft errors in CIEDs","volume":"5","author":"Kawakami Y","year":"2024","unstructured":"Kawakami Y, Sakai M, Masuda H, et al.. The contribution of secondary particles following carbon ion radiotherapy to soft errors in CIEDs. IEEE Open J Eng Med Biol. 2024, 5:157-62. 10.1109\/OJEMB.2024.3358989","journal-title":"IEEE Open J Eng Med Biol"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1118\/1.3220624","article-title":"Monte Carlo study on secondary neutrons in passive carbon-ion radiotherapy: identification of the main source and reduction in the secondary neutron dose","volume":"36","author":"Yonai S","year":"2009","unstructured":"Yonai S, Matsufuji N, Kanai T. Monte Carlo study on secondary neutrons in passive carbon-ion radiotherapy: identification of the main source and reduction in the secondary neutron dose. Med Phys. 2009, 36:4830-9. 10.1118\/1.3220624","journal-title":"Med Phys"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1109\/TNS.2023.3245142","article-title":"Energy-resolved SEU cross section from 10-meV to 800-MeV neutrons by time-of-flight measurement","volume":"70","author":"Iwashita H","year":"2023","unstructured":"Iwashita H, Kiuchi R, Hiroshima Y, et al.. Energy-resolved SEU cross section from 10-meV to 800-MeV neutrons by time-of-flight measurement. IEEE Trans Nucl Sci. 2023, 70:216-21. 10.1109\/TNS.2023.3245142","journal-title":"IEEE Trans Nucl Sci"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.1016\/j.nimb.2024.165384","article-title":"Soft error measurement for carbon ion radiotherapy","volume":"553","author":"Sakai M","year":"2024","unstructured":"Sakai M, Miyajima M, Kawakami Y, et al.. Soft error measurement for carbon ion radiotherapy. Nucl Instrum Methods Phys Res Sect B. 2024, 553:165384-0168. 10.1016\/j.nimb.2024.165384","journal-title":"Nucl Instrum Methods Phys Res Sect B"},{"key":"ref15","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/aa6b45","article-title":"Implementation of tetrahedral-mesh geometry in Monte Carlo radiation transport code PHITS","volume":"62","author":"Furuta T","year":"2017","unstructured":"Furuta T, Sato T, Han MC, Yeom YS, Kim CH, Brown JL, Bolch WE. Implementation of tetrahedral-mesh geometry in Monte Carlo radiation transport code PHITS. Phys Med Biol. 2017, 62:4798-810. 10.1088\/1361-6560\/aa6b45","journal-title":"Phys Med Biol"},{"key":"ref16","doi-asserted-by":"publisher","DOI":"10.1093\/jrr\/rraa102","article-title":"JASTRO\/JCS Guidelines for radiotherapy in patients with cardiac implantable electronic devices","volume":"62","author":"Ohno T","year":"2020","unstructured":"Ohno T, Soejima T, Sekiguchi Y, et al.. JASTRO\/JCS Guidelines for radiotherapy in patients with cardiac implantable electronic devices. J Radiat Res. 2020, 62:172-84. 10.1093\/jrr\/rraa102","journal-title":"J Radiat Res"},{"key":"ref17","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrthm.2020.10.009","article-title":"Cybersecurity: the need for data and patient safety with cardiac implantable electronic devices","volume":"18","author":"Das S","year":"2021","unstructured":"Das S, Siroky GP, Lee S, Mehta D, Suri R. Cybersecurity: the need for data and patient safety with cardiac implantable electronic devices. Heart Rhythm. 2021, 18:473-81. 10.1016\/j.hrthm.2020.10.009","journal-title":"Heart Rhythm"},{"key":"ref18","doi-asserted-by":"publisher","DOI":"10.1016\/0360-3016(91)90249-4","article-title":"On using the linear-quadratic model in daily clinical practice","volume":"20","author":"Yaes RJ","year":"1991","unstructured":"Yaes RJ, Patel P, Maruyama Y. On using the linear-quadratic model in daily clinical practice. Int J Radiat Oncol Biol Phys. 1991, 20:1353-62. 10.1016\/0360-3016(91)90249-4","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"ref19","doi-asserted-by":"publisher","DOI":"10.1097\/JTO.0b013e318074de34","article-title":"Hypofractionated stereotactic radiotherapy (HypoFXSRT) for stage I non-small cell lung cancer: updated results of 257 patients in a Japanese multi-institutional study","volume":"2","author":"Onishi H","year":"2007","unstructured":"Onishi H, Shirato H, Nagata Y, et al.. Hypofractionated stereotactic radiotherapy (HypoFXSRT) for stage I non-small cell lung cancer: updated results of 257 patients in a Japanese multi-institutional study. J Thorac Oncol. 2007, 2:S94-100. 10.1097\/JTO.0b013e318074de34","journal-title":"J Thorac Oncol"},{"key":"ref20","unstructured":"Guidelines for radiation therapy for patients with implantable cardiac electrical devices. (2019). https.\/\/www.jastro.or.jp\/medicalpersonnel\/guideline\/20191025.pdf."}],"container-title":["Cureus"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cureus.com\/articles\/352502-pacemaker-malfunction-triggered-by-cybersecurity-activation-during-carbon-ion-radiotherapy-a-case-report","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,10]],"date-time":"2025-05-10T13:35:52Z","timestamp":1746884152000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cureus.com\/articles\/352502-pacemaker-malfunction-triggered-by-cybersecurity-activation-during-carbon-ion-radiotherapy-a-case-report"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,5,10]]},"references-count":20,"URL":"https:\/\/doi.org\/10.7759\/cureus.83835","relation":{},"ISSN":["2168-8184"],"issn-type":[{"value":"2168-8184","type":"print"}],"subject":[],"published":{"date-parts":[[2025,5,10]]}}}