{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,17]],"date-time":"2026-10-17T20:41:48Z","timestamp":1792269708234,"version":"4.4.0"},"reference-count":13,"publisher":"Springer Science and Business Media LLC","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2025,5,30]]},"DOI":"10.7759\/cureus.85078","type":"journal-article","created":{"date-parts":[[2025,5,30]],"date-time":"2025-05-30T11:29:39Z","timestamp":1748604579000},"source":"Crossref","is-referenced-by-count":1,"title":["A Case of Corneal Endothelial Cell Loss After PreserFlo MicroShunt Implantation Requiring Device Removal and Ahmed Glaucoma Valve Implantation With Tube Insertion Into the Vitreous Cavity"],"prefix":"10.7759","author":[{"given":"Tomoyuki","family":"Watanabe","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Koki","family":"Honzawa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hisato","family":"Gunji","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hiroshi","family":"Horiguchi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tadashi","family":"Nakano","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1186\/s40662-023-00369-8","article-title":"PRESERFLO MicroShunt implantation versus trabeculectomy for primary open-angle glaucoma: a two-year follow-up study","volume":"10","author":"Gubser PA","year":"2023","unstructured":"Gubser PA, Pfeiffer V, Hug S, et al.. PRESERFLO MicroShunt implantation versus trabeculectomy for primary open-angle glaucoma: a two-year follow-up study. Eye Vis (Lond). 2023, 10:50. 10.1186\/s40662-023-00369-8","journal-title":"Eye Vis (Lond)"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2021.05.023","article-title":"Ab-externo MicroShunt versus trabeculectomy in primary open-angle glaucoma: one-year results from a 2-year randomized, multicenter study","volume":"128","author":"Baker ND","year":"2021","unstructured":"Baker ND, Barnebey HS, Moster MR, et al.. Ab-externo MicroShunt versus trabeculectomy in primary open-angle glaucoma: one-year results from a 2-year randomized, multicenter study. Ophthalmology. 2021, 128:1710-21. 10.1016\/j.ophtha.2021.05.023","journal-title":"Ophthalmology"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajoc.2021.101238","article-title":"Endothelial cell loss 5 years after Preserflo MicroShunt implantation: about two cases","volume":"25","author":"Chamard C","year":"2022","unstructured":"Chamard C, Hammoud S, Bluwol E, Lachkar Y. Endothelial cell loss 5 years after Preserflo MicroShunt implantation: about two cases. Am J Ophthalmol Case Rep. 2022, 25:101238. 10.1016\/j.ajoc.2021.101238","journal-title":"Am J Ophthalmol Case Rep"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1007\/s40123-021-00428-0","article-title":"Corneal endothelial cell loss after PRESERFLO\u2122 MicroShunt implantation in the anterior chamber: anterior segment OCT tube location as a risk factor","volume":"11","author":"Ibarz-Barber\u00e1 M","year":"2022","unstructured":"Ibarz-Barber\u00e1 M, Morales-Fern\u00e1ndez L, Corroto-Cuadrado A, Martinez-Gald\u00f3n F, Ta\u00f1\u00e1-Rivero P, G\u00f3mez de Lia\u00f1o R, Teus MA. Corneal endothelial cell loss after PRESERFLO\u2122 MicroShunt implantation in the anterior chamber: anterior segment OCT tube location as a risk factor. Ophthalmol Ther. 2022, 11:293-310. 10.1007\/s40123-021-00428-0","journal-title":"Ophthalmol Ther"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1097\/IJG.0000000000002325","article-title":"Preserflo MicroShunt: efficacy and endothelial cell density","volume":"32","author":"Anton Steindor F","year":"2023","unstructured":"Anton Steindor F, Trigaux C, Holtmann C, Spaniol K, Geerling G, Borrelli M. Preserflo MicroShunt: efficacy and endothelial cell density. J Glaucoma. 2023, 32:1018-21. 10.1097\/IJG.0000000000002325","journal-title":"J Glaucoma"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1136\/bjophthalmol-2018-313417","article-title":"Effect of trabeculectomy on corneal endothelial cell loss","volume":"104","author":"Hirooka K","year":"2020","unstructured":"Hirooka K, Nitta E, Ukegawa K, Sato S, Kiuchi Y. Effect of trabeculectomy on corneal endothelial cell loss. Br J Ophthalmol. 2020, 104:376-80. 10.1136\/bjophthalmol-2018-313417","journal-title":"Br J Ophthalmol"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1097\/IJG.0000000000001108","article-title":"Determinants of corneal endothelial cell loss after trabeculectomy with mitomycin C","volume":"28","author":"Higashide T","year":"2019","unstructured":"Higashide T, Nishino T, Sakaguchi K, Yamada Y, Sugiyama K. Determinants of corneal endothelial cell loss after trabeculectomy with mitomycin C. J Glaucoma. 2019, 28:61-7. 10.1097\/IJG.0000000000001108","journal-title":"J Glaucoma"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1016\/j.ogla.2020.06.012","article-title":"Corneal endothelial cell loss after Baerveldt glaucoma implant surgery","volume":"4","author":"Hau S","year":"2021","unstructured":"Hau S, Bunce C, Barton K. Corneal endothelial cell loss after Baerveldt glaucoma implant surgery. Ophthalmol Glaucoma. 2021, 4:20-31. 10.1016\/j.ogla.2020.06.012","journal-title":"Ophthalmol Glaucoma"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-021-92420-8","article-title":"Corneal endothelial cell changes and surgical results after Ahmed glaucoma valve implantation: ciliary sulcus versus anterior chamber tube placement","volume":"11","author":"Kim JY","year":"2021","unstructured":"Kim JY, Lee JS, Lee T, Seo D, Choi W, Bae HW, Kim CY. Corneal endothelial cell changes and surgical results after Ahmed glaucoma valve implantation: ciliary sulcus versus anterior chamber tube placement. Sci Rep. 2021, 11:12986. 10.1038\/s41598-021-92420-8","journal-title":"Sci Rep"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.1097\/IJG.0000000000001884","article-title":"Surgical results of Ahmed glaucoma valve implantation in one-chamber eyes","volume":"30","author":"Tanito M","year":"2021","unstructured":"Tanito M, Tsutsui A, Manabe K, Matsuoka Y. Surgical results of Ahmed glaucoma valve implantation in one-chamber eyes. J Glaucoma. 2021, 30:e327-33. 10.1097\/IJG.0000000000001884","journal-title":"J Glaucoma"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.3390\/jcm10081606","article-title":"Autologous scleral pocket technique for Ahmed glaucoma valve implantation with pars plana tube insertion for neovascular glaucoma","volume":"10","author":"Maki H","year":"2021","unstructured":"Maki H, Mori S, Imai H, et al.. Autologous scleral pocket technique for Ahmed glaucoma valve implantation with pars plana tube insertion for neovascular glaucoma. J Clin Med. 2021, 10:1606. 10.3390\/jcm10081606","journal-title":"J Clin Med"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2020.12.006","article-title":"Potential functional restoration of corneal endothelial cells in Fuchs endothelial corneal dystrophy by ROCK inhibitor (ripasudil)","volume":"224","author":"Schl\u00f6tzer-Schrehardt U","year":"2021","unstructured":"Schl\u00f6tzer-Schrehardt U, Zenkel M, Strunz M, et al.. Potential functional restoration of corneal endothelial cells in Fuchs endothelial corneal dystrophy by ROCK inhibitor (ripasudil). Am J Ophthalmol. 2021, 224:185-99. 10.1016\/j.ajo.2020.12.006","journal-title":"Am J Ophthalmol"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1155\/2017\/2646904","article-title":"Application of rho kinase inhibitors for the treatment of corneal endothelial diseases","volume":"2017","author":"Okumura N","year":"2017","unstructured":"Okumura N, Kinoshita S, Koizumi N. Application of rho kinase inhibitors for the treatment of corneal endothelial diseases. J Ophthalmol. 2017, 2017:2646904. 10.1155\/2017\/2646904","journal-title":"J Ophthalmol"}],"container-title":["Cureus"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cureus.com\/articles\/366050-a-case-of-corneal-endothelial-cell-loss-after-preserflo-microshunt-implantation-requiring-device-removal-and-ahmed-glaucoma-valve-implantation-with-tube-insertion-into-the-vitreous-cavity","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,30]],"date-time":"2025-05-30T11:29:40Z","timestamp":1748604580000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cureus.com\/articles\/366050-a-case-of-corneal-endothelial-cell-loss-after-preserflo-microshunt-implantation-requiring-device-removal-and-ahmed-glaucoma-valve-implantation-with-tube-insertion-into-the-vitreous-cavity"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,5,30]]},"references-count":13,"URL":"https:\/\/doi.org\/10.7759\/cureus.85078","relation":{},"ISSN":["2168-8184"],"issn-type":[{"value":"2168-8184","type":"print"}],"subject":[],"published":{"date-parts":[[2025,5,30]]}}}