{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,6,1]],"date-time":"2025-06-01T17:40:06Z","timestamp":1748799606383,"version":"3.41.0"},"reference-count":15,"publisher":"Springer Science and Business Media LLC","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2025,6,1]]},"DOI":"10.7759\/cureus.85192","type":"journal-article","created":{"date-parts":[[2025,6,1]],"date-time":"2025-06-01T17:11:16Z","timestamp":1748797876000},"source":"Crossref","is-referenced-by-count":0,"title":["Heat and Moisture Exchanger Malfunction Causing Dynamic Hyperinflation and Ventilatory Insufficiency Under General Anesthesia: A Case Report"],"prefix":"10.7759","author":[{"given":"Subham","family":"Das","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Pankaj","family":"Deori","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sristi","family":"Kumari","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Habib Md R","family":"Karim","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1186\/cc361","article-title":"Mechanical effects of heat-moisture exchangers in ventilated patients","volume":"3","author":"Iotti GA","year":"1999","unstructured":"Iotti GA, Olivei MC, Braschi A. Mechanical effects of heat-moisture exchangers in ventilated patients. Crit Care. 1999, 3:R77. 10.1186\/cc361","journal-title":"Crit Care"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.2010.06564.x","article-title":"Heat and moisture exchangers and breathing system filters: their use in anaesthesia and intensive care. Part 2 \u2014 practical use, including problems, and their use with paediatric patients","volume":"66","author":"Wilkes AR","year":"2011","unstructured":"Wilkes AR. Heat and moisture exchangers and breathing system filters: their use in anaesthesia and intensive care. Part 2 \u2014 practical use, including problems, and their use with paediatric patients. Anaesthesia. 2011, 66:40-51. 10.1111\/j.1365-2044.2010.06564.x","journal-title":"Anaesthesia"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.2010.06563.x","article-title":"Heat and moisture exchangers and breathing system filters: their use in anaesthesia and intensive care. Part 1 \u2014 history, principles and efficiency","volume":"66","author":"Wilkes AR","year":"2011","unstructured":"Wilkes AR. Heat and moisture exchangers and breathing system filters: their use in anaesthesia and intensive care. Part 1 \u2014 history, principles and efficiency. Anaesthesia. 2011, 66:31-39. 10.1111\/j.1365-2044.2010.06563.x","journal-title":"Anaesthesia"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1164\/rccm.201102-0226PP","article-title":"Dynamic hyperinflation and auto-positive end-expiratory pressure: lessons learned over 30 years","volume":"184","author":"Marini JJ","year":"2011","unstructured":"Marini JJ. Dynamic hyperinflation and auto-positive end-expiratory pressure: lessons learned over 30 years. Am J Respir Crit Care Med. 2011, 184:756-762. 10.1164\/rccm.201102-0226PP","journal-title":"Am J Respir Crit Care Med"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.1978.tb08464.x","article-title":"Excessive airway pressure during anaesthesia. Hazards, effects and prevention","volume":"33","author":"Newton NI","year":"1978","unstructured":"Newton NI, Adams AP. Excessive airway pressure during anaesthesia. Hazards, effects and prevention. Anaesthesia. 1978, 33:689-699. 10.1111\/j.1365-2044.1978.tb08464.x","journal-title":"Anaesthesia"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.4103\/1658-354X.146326","article-title":"An unusual cause of high peak airway pressure: interpretation of displayed alarms","volume":"9","author":"Vinay B","year":"2015","unstructured":"Vinay B, Sriganesh K, Gopalakrishna KN, Sudhir V. An unusual cause of high peak airway pressure: interpretation of displayed alarms. Saudi J Anaesth. 2015, 9:94-96. 10.4103\/1658-354X.146326","journal-title":"Saudi J Anaesth"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/74.3.340","article-title":"Intraoperative cardiac arrest after unrecognized dynamic hyperinflation","volume":"74","author":"Myles PS","year":"1995","unstructured":"Myles PS, Madder H, Morgan EB. Intraoperative cardiac arrest after unrecognized dynamic hyperinflation. Br J Anaesth. 1995, 74:340-342. 10.1093\/bja\/74.3.340","journal-title":"Br J Anaesth"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.4103\/0019-5049.165859","article-title":"Anaesthesia for patient with chronic obstructive pulmonary disease","volume":"59","author":"Duggappa DR","year":"2015","unstructured":"Duggappa DR, Rao GV, Kannan S. Anaesthesia for patient with chronic obstructive pulmonary disease. Indian J Anaesth. 2015, 59:574-83. 10.4103\/0019-5049.165859","journal-title":"Indian J Anaesth"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.1007\/s12630-011-9459-9","article-title":"Dynamic hyperinflation and cardiac arrest during one-lung ventilation: a case report","volume":"58","author":"Marseu K","year":"2011","unstructured":"Marseu K, Slinger P, de Perrot M, McRae K, Ma M. Dynamic hyperinflation and cardiac arrest during one-lung ventilation: a case report. Can J Anaesth. 2011, 58:396-400. 10.1007\/s12630-011-9459-9","journal-title":"Can J Anaesth"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.4103\/0019-5049.139017","article-title":"Use of filters in anaesthesia: Is it warranted?","volume":"58","author":"Chellam S","year":"2014","unstructured":"Chellam S, Dalal KS, Toal PV. Use of filters in anaesthesia: Is it warranted?. Indian J Anaesth. 2014, 58:475-477. 10.4103\/0019-5049.139017","journal-title":"Indian J Anaesth"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1213\/XAA.0000000000001483","article-title":"High Peak inspiratory pressures after a change of heat and moisture exchangers: a case series","volume":"15","author":"Dewasurendra AM","year":"2021","unstructured":"Dewasurendra AM, McHugh SM. High Peak inspiratory pressures after a change of heat and moisture exchangers: a case series. A A Pract. 2021, 15:e01483. 10.1213\/XAA.0000000000001483","journal-title":"A A Pract"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.2012.07163.x","article-title":"Checking anaesthetic equipment 2012: association of anaesthetists of Great Britain and Ireland","volume":"67","author":"Hartle A","year":"2012","unstructured":"Hartle A, Anderson E, Bythell V, et al.. Checking anaesthetic equipment 2012: association of anaesthetists of Great Britain and Ireland. Anaesthesia. 2012, 67:660-668. 10.1111\/j.1365-2044.2012.07163.x","journal-title":"Anaesthesia"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1164\/ajrccm.152.5.7582295","article-title":"Changing heat and moisture exchangers every 48 hours rather than 24 hours does not affect their efficacy and the incidence of nosocomial pneumonia","volume":"152","author":"Djedaini K","year":"1995","unstructured":"Djedaini K, Billiard M, Mier L, et al.. Changing heat and moisture exchangers every 48 hours rather than 24 hours does not affect their efficacy and the incidence of nosocomial pneumonia. Am J Respir Crit Care Med. 1995, 152:1562-1569. 10.1164\/ajrccm.152.5.7582295","journal-title":"Am J Respir Crit Care Med"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.3390\/medsci12020026","article-title":"Humidification during invasive and non-invasive ventilation: a starting tool kit for correct setting","volume":"12","author":"Re R","year":"2024","unstructured":"Re R, Lassola S, De Rosa S, Bellani G. Humidification during invasive and non-invasive ventilation: a starting tool kit for correct setting. Med Sci (Basel). 2024, 12:26. 10.3390\/medsci12020026","journal-title":"Med Sci (Basel)"},{"key":"ref15","doi-asserted-by":"publisher","DOI":"10.5005\/jp-journals-11010-05208","article-title":"HME filters: a boon or bane?","volume":"5","author":"Prasad S","year":"2016","unstructured":"Prasad S, Gaude Y. HME filters: a boon or bane?. Ind J Resp Care. 2016, 5:745-748. 10.5005\/jp-journals-11010-05208","journal-title":"Ind J Resp Care"}],"container-title":["Cureus"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cureus.com\/articles\/375267-heat-and-moisture-exchanger-malfunction-causing-dynamic-hyperinflation-and-ventilatory-insufficiency-under-general-anesthesia-a-case-report","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,1]],"date-time":"2025-06-01T17:11:16Z","timestamp":1748797876000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cureus.com\/articles\/375267-heat-and-moisture-exchanger-malfunction-causing-dynamic-hyperinflation-and-ventilatory-insufficiency-under-general-anesthesia-a-case-report"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,6,1]]},"references-count":15,"URL":"https:\/\/doi.org\/10.7759\/cureus.85192","relation":{},"ISSN":["2168-8184"],"issn-type":[{"value":"2168-8184","type":"print"}],"subject":[],"published":{"date-parts":[[2025,6,1]]}}}