{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,8,2]],"date-time":"2025-08-02T19:06:16Z","timestamp":1754161576466,"version":"3.41.2"},"reference-count":17,"publisher":"Springer Science and Business Media LLC","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2025,7,28]]},"DOI":"10.7759\/cureus.88942","type":"journal-article","created":{"date-parts":[[2025,7,29]],"date-time":"2025-07-29T04:09:16Z","timestamp":1753762156000},"source":"Crossref","is-referenced-by-count":0,"title":["A Trajectory Close to the Anterolateral Vertebral Wall Becomes a Risk Factor for Intravascular Cement Leakage During Insertion of Cement-Augmented Fenestrated Pedicle Screws"],"prefix":"10.7759","author":[{"given":"Reimi","family":"Ikeda","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Itsuo","family":"Shiina","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takane","family":"Nakagawa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kazuhiro","family":"Ikeda","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hironori","family":"Takehashi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takao","family":"Mizumachi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ikuo","family":"Sugaya","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Masao","family":"Koda","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hiroshi","family":"Takahashi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1359\/jbmr.061113","article-title":"Incidence and economic burden of osteoporosis-related fractures in the United States, 2005-2025","volume":"22","author":"Burge R","year":"2007","unstructured":"Burge R, Dawson-Hughes B, Solomon DH, Wong JB, King A, Tosteson A. Incidence and economic burden of osteoporosis-related fractures in the United States, 2005-2025. J Bone Miner Res. 2007, 22:465-75. 10.1359\/jbmr.061113","journal-title":"J Bone Miner Res"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1007\/s00068-013-0310-6","article-title":"Reduced loosening rate and loss of correction following posterior stabilization with or without PMMA augmentation of pedicle screws in vertebral fractures in the elderly","volume":"39","author":"El Saman A","year":"2013","unstructured":"El Saman A, Meier S, Sander A, Kelm A, Marzi I, Laurer H. Reduced loosening rate and loss of correction following posterior stabilization with or without PMMA augmentation of pedicle screws in vertebral fractures in the elderly. Eur J Trauma Emerg Surg. 2013, 39:455-60. 10.1007\/s00068-013-0310-6","journal-title":"Eur J Trauma Emerg Surg"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1007\/s00586-015-3768-6","article-title":"Pedicle screw loosening: a clinically relevant complication?","volume":"24","author":"Galbusera F","year":"2015","unstructured":"Galbusera F, Volkheimer D, Reitmaier S, Berger-Roscher N, Kienle A, Wilke HJ. Pedicle screw loosening: a clinically relevant complication?. Eur Spine J. 2015, 24:1005-16. 10.1007\/s00586-015-3768-6","journal-title":"Eur Spine J"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1016\/s1529-9430(01)00078-x","article-title":"Influence of bone mineral density on pedicle screw fixation: a study of pedicle screw fixation augmenting posterior lumbar interbody fusion in elderly patients","volume":"1","author":"Okuyama K","year":"2001","unstructured":"Okuyama K, Abe E, Suzuki T, Tamura Y, Chiba M, Sato K. Influence of bone mineral density on pedicle screw fixation: a study of pedicle screw fixation augmenting posterior lumbar interbody fusion in elderly patients. Spine J. 2001, 1:402-7. 10.1016\/s1529-9430(01)00078-x","journal-title":"Spine J"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.3390\/jcm11092577","article-title":"Innovation of surgical techniques for screw fixation in patients with osteoporotic spine","volume":"11","author":"Kanno H","year":"2022","unstructured":"Kanno H, Onoda Y, Hashimoto K, Aizawa T, Ozawa H. Innovation of surgical techniques for screw fixation in patients with osteoporotic spine. J Clin Med. 2022, 11:10.3390\/jcm11092577","journal-title":"J Clin Med"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.3171\/2020.10.SPINE201387","article-title":"Posterior spinal fixation using penetrating endplate screws in patients with diffuse idiopathic skeletal hyperostosis-related thoracolumbar fractures","volume":"34","author":"Hishiya T","year":"2021","unstructured":"Hishiya T, Ishikawa T, Ota M. Posterior spinal fixation using penetrating endplate screws in patients with diffuse idiopathic skeletal hyperostosis-related thoracolumbar fractures. J Neurosurg Spine. 2021, 34:936-41. 10.3171\/2020.10.SPINE201387","journal-title":"J Neurosurg Spine"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1007\/s10195-011-0164-9","article-title":"Fenestrated pedicle screws for cement-augmented purchase in patients with bone softening: a review of 21 cases","volume":"12","author":"Amendola L","year":"2011","unstructured":"Amendola L, Gasbarrini A, Fosco M, Simoes CE, Terzi S, De Iure F, Boriani S. Fenestrated pedicle screws for cement-augmented purchase in patients with bone softening: a review of 21 cases. J Orthop Traumatol. 2011, 12:193-9. 10.1007\/s10195-011-0164-9","journal-title":"J Orthop Traumatol"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1097\/BRS.0b013e3182740e56","article-title":"Pedicle screw design and cement augmentation in osteoporotic vertebrae: effects of fenestrations and cement viscosity on fixation and extraction","volume":"37","author":"Choma TJ","year":"2012","unstructured":"Choma TJ, Pfeiffer FM, Swope RW, Hirner JP. Pedicle screw design and cement augmentation in osteoporotic vertebrae: effects of fenestrations and cement viscosity on fixation and extraction. Spine (Phila Pa 1976). 2012, 37:E1628-32. 10.1097\/BRS.0b013e3182740e56","journal-title":"Spine (Phila Pa 1976)"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.4055\/cios19127","article-title":"Clinical effects and complications of pedicle screw augmentation with bone cement: comparison of fenestrated screw augmentation and vertebroplasty augmentation","volume":"12","author":"Kim JH","year":"2020","unstructured":"Kim JH, Ahn DK, Shin WS, Kim MJ, Lee HY, Go YR. Clinical effects and complications of pedicle screw augmentation with bone cement: comparison of fenestrated screw augmentation and vertebroplasty augmentation. Clin Orthop Surg. 2020, 12:194-9. 10.4055\/cios19127","journal-title":"Clin Orthop Surg"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.4103\/jcvjs.JCVJS_14_18","article-title":"Augmentation of fenestrated pedicle screws with cement in patients with osteoporotic spine","volume":"9","author":"Abousayed M","year":"2018","unstructured":"Abousayed M, Boktor JG, Sultan AM, Koptan W, El-Miligui Y. Augmentation of fenestrated pedicle screws with cement in patients with osteoporotic spine. J Craniovertebr Junction Spine. 2018, 9:20-5. 10.4103\/jcvjs.JCVJS_14_18","journal-title":"J Craniovertebr Junction Spine"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1186\/s12891-020-03309-y","article-title":"Effect and potential risks of using multilevel cement-augmented pedicle screw fixation in osteoporotic spine with lumbar degenerative disease","volume":"21","author":"Tang YC","year":"2020","unstructured":"Tang YC, Guo HZ, Guo DQ, et al.. Effect and potential risks of using multilevel cement-augmented pedicle screw fixation in osteoporotic spine with lumbar degenerative disease. BMC Musculoskelet Disord. 2020, 21:274. 10.1186\/s12891-020-03309-y","journal-title":"BMC Musculoskelet Disord"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1016\/j.spinee.2017.01.009","article-title":"Risk of cement leakage and pulmonary embolism by bone cement-augmented pedicle screw fixation of the thoracolumbar spine","volume":"17","author":"Janssen I","year":"2017","unstructured":"Janssen I, Ryang YM, Gempt J, Bette S, Gerhardt J, Kirschke JS, Meyer B. Risk of cement leakage and pulmonary embolism by bone cement-augmented pedicle screw fixation of the thoracolumbar spine. Spine J. 2017, 17:837-44. 10.1016\/j.spinee.2017.01.009","journal-title":"Spine J"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.3390\/medicina59020407","article-title":"Cardiopulmonary cement embolism following cement-augmented pedicle screw fixation: a narrative review","volume":"59","author":"Morimoto T","year":"2023","unstructured":"Morimoto T, Kobayashi T, Hirata H, Tsukamoto M, Yoshihara T, Toda Y, Mawatari M. Cardiopulmonary cement embolism following cement-augmented pedicle screw fixation: a narrative review. Medicina (Kaunas). 2023, 59:10.3390\/medicina59020407","journal-title":"Medicina (Kaunas)"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.1016\/j.wneu.2019.05.047","article-title":"Early complications and cement leakage in elderly patients who have undergone intraoperative computed tomography (CT)-guided cement augmented pedicle screw placement: eight-year single-center experience","volume":"128","author":"Ishak B","year":"2019","unstructured":"Ishak B, Bajwa AA, Schneider T, et al.. Early complications and cement leakage in elderly patients who have undergone intraoperative computed tomography (CT)-guided cement augmented pedicle screw placement: eight-year single-center experience. World Neurosurg. 2019, 128:e975-81. 10.1016\/j.wneu.2019.05.047","journal-title":"World Neurosurg"},{"key":"ref15","doi-asserted-by":"publisher","DOI":"10.1007\/s00586-018-5593-1","article-title":"Pulmonary cement embolism following cement-augmented fenestrated pedicle screw fixation in adult spinal deformity patients with severe osteoporosis (analysis of 2978 fenestrated screws)","volume":"27","author":"Ulusoy OL","year":"2018","unstructured":"Ulusoy OL, Kahraman S, Karalok I, et al.. Pulmonary cement embolism following cement-augmented fenestrated pedicle screw fixation in adult spinal deformity patients with severe osteoporosis (analysis of 2978 fenestrated screws). Eur Spine J. 2018, 27:2348-56. 10.1007\/s00586-018-5593-1","journal-title":"Eur Spine J"},{"key":"ref16","doi-asserted-by":"publisher","DOI":"10.31662\/jmaj.2021-0065","article-title":"The relationship between perivertebral venous cement embolism and balloon expansion pressure in balloon kyphoplasty","volume":"4","author":"Tabata Y","year":"2021","unstructured":"Tabata Y, Matsui S, Miyamoto M, Nakajima T, Majima T. The relationship between perivertebral venous cement embolism and balloon expansion pressure in balloon kyphoplasty. JMA J. 2021, 4:367-73. 10.31662\/jmaj.2021-0065","journal-title":"JMA J"},{"key":"ref17","doi-asserted-by":"publisher","DOI":"10.1080\/17434440.2021.1977123","article-title":"Comparison of clinical effectiveness of fenestrated and conventional pedicle screws in patients undergoing spinal surgery: a systematic review and meta-analysis","volume":"18","author":"Yagi M","year":"2021","unstructured":"Yagi M, Ogiri M, Holy CE, Bourcet A. Comparison of clinical effectiveness of fenestrated and conventional pedicle screws in patients undergoing spinal surgery: a systematic review and meta-analysis. Expert Rev Med Devices. 2021, 18:995-1022. 10.1080\/17434440.2021.1977123","journal-title":"Expert Rev Med Devices"}],"container-title":["Cureus"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cureus.com\/articles\/375186-a-trajectory-close-to-the-anterolateral-vertebral-wall-becomes-a-risk-factor-for-intravascular-cement-leakage-during-insertion-of-cement-augmented-fenestrated-pedicle-screws","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,7,29]],"date-time":"2025-07-29T04:09:17Z","timestamp":1753762157000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cureus.com\/articles\/375186-a-trajectory-close-to-the-anterolateral-vertebral-wall-becomes-a-risk-factor-for-intravascular-cement-leakage-during-insertion-of-cement-augmented-fenestrated-pedicle-screws"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,7,28]]},"references-count":17,"URL":"https:\/\/doi.org\/10.7759\/cureus.88942","relation":{},"ISSN":["2168-8184"],"issn-type":[{"type":"print","value":"2168-8184"}],"subject":[],"published":{"date-parts":[[2025,7,28]]}}}