{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T05:20:16Z","timestamp":1790745616520,"version":"4.1.0"},"reference-count":54,"publisher":"Springer Science and Business Media LLC","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2025,8,26]]},"DOI":"10.7759\/cureus.91030","type":"journal-article","created":{"date-parts":[[2025,8,26]],"date-time":"2025-08-26T14:49:59Z","timestamp":1756219799000},"source":"Crossref","is-referenced-by-count":3,"title":["Integrating Gait Analysis Systems in Clinical Rehabilitation Settings for Individuals With Lower Limb Amputation: A Narrative Review"],"prefix":"10.7759","author":[{"given":"Xiaoning","family":"Yuan","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tawnee","family":"Sparling","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David","family":"Carlisle","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shannon","family":"McGavin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tiffany","family":"Riggleman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Emmanuel","family":"Cuevas","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shubham","family":"Ojha","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Douglas G","family":"Smith","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gabriel","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1177\/0309364620972258","article-title":"Global prevalence of traumatic non-fatal limb amputation","volume":"45","author":"McDonald CL","year":"2021","unstructured":"McDonald CL, Westcott-McCoy S, Weaver MR, Haagsma J, Kartin D. Global prevalence of traumatic non-fatal limb amputation. Prosthet Orthot Int. 2021, 45:105-14. 10.1177\/0309364620972258","journal-title":"Prosthet Orthot Int"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1016\/j.apmr.2007.11.005","article-title":"Estimating the prevalence of limb loss in the United States: 2005 to 2050","volume":"89","author":"Ziegler-Graham K","year":"2008","unstructured":"Ziegler-Graham K, MacKenzie EJ, Ephraim PL, Travison TG, Brookmeyer R. Estimating the prevalence of limb loss in the United States: 2005 to 2050. Arch Phys Med Rehabil. 2008, 89:422-9. 10.1016\/j.apmr.2007.11.005","journal-title":"Arch Phys Med Rehabil"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1016\/j.pmr.2013.09.006","article-title":"Gait analysis in lower-limb amputation and prosthetic rehabilitation","volume":"25","author":"Esquenazi A","year":"2014","unstructured":"Esquenazi A. Gait analysis in lower-limb amputation and prosthetic rehabilitation. Phys Med Rehabil Clin N Am. 2014, 25:153-67. 10.1016\/j.pmr.2013.09.006","journal-title":"Phys Med Rehabil Clin N Am"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1016\/j.spinee.2018.08.011","article-title":"Low back pain in persons with lower extremity amputation: a systematic review of the literature","volume":"19","author":"Highsmith MJ","year":"2019","unstructured":"Highsmith MJ, Goff LM, Lewandowski AL, et al.. Low back pain in persons with lower extremity amputation: a systematic review of the literature. Spine J. 2019, 19:552-63. 10.1016\/j.spinee.2018.08.011","journal-title":"Spine J"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.7717\/peerj.2960","article-title":"Medial knee joint contact force in the intact limb during walking in recently ambulatory service members with unilateral limb loss: a cross-sectional study","volume":"5","author":"Miller RH","year":"2017","unstructured":"Miller RH, Krupenevich RL, Pruziner AL, Wolf EJ, Schnall BL. Medial knee joint contact force in the intact limb during walking in recently ambulatory service members with unilateral limb loss: a cross-sectional study. PeerJ. 2017, 5:e2960. 10.7717\/peerj.2960","journal-title":"PeerJ"},{"key":"ref6","doi-asserted-by":"crossref","DOI":"10.2106\/00004623-195335030-00003","article-title":"The major determinants in normal and pathological gait","volume":"35","author":"Saunders J","year":"1953","unstructured":"Saunders J, Inman V, Eberhart H. The major determinants in normal and pathological gait. J Bone Joint Surg Am. 1953, 35:543-58.","journal-title":"J Bone Joint Surg Am"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0241922","article-title":"Clinicians' perspectives on inertial measurement units in clinical practice","volume":"15","author":"Routhier F","year":"2020","unstructured":"Routhier F, Duclos NC, Lacroix \u00c9, et al.. Clinicians' perspectives on inertial measurement units in clinical practice. PLoS One. 2020, 15:e0241922. 10.1371\/journal.pone.0241922","journal-title":"PLoS One"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1016\/j.gaitpost.2017.08.003","article-title":"SIAMOC position paper on gait analysis in clinical practice: general requirements, methods and appropriateness. Results of an Italian consensus conference","volume":"58","author":"Benedetti MG","year":"2017","unstructured":"Benedetti MG, Beghi E, De Tanti A, et al.. SIAMOC position paper on gait analysis in clinical practice: general requirements, methods and appropriateness. Results of an Italian consensus conference. Gait Posture. 2017, 58:252-60. 10.1016\/j.gaitpost.2017.08.003","journal-title":"Gait Posture"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.1080\/09638288.2017.1342281","article-title":"Ambivalence in rehabilitation: thematic analysis of the experiences of lower limb amputated veterans","volume":"40","author":"Christensen J","year":"2018","unstructured":"Christensen J, Langberg H, Doherty P, Egerod I. Ambivalence in rehabilitation: thematic analysis of the experiences of lower limb amputated veterans. Disabil Rehabil. 2018, 40:2553-60. 10.1080\/09638288.2017.1342281","journal-title":"Disabil Rehabil"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.1097\/MOP.0b013e3280118a6d","article-title":"The role of gait analysis in the orthopaedic management of ambulatory cerebral palsy","volume":"19","author":"Narayanan UG","year":"2007","unstructured":"Narayanan UG. The role of gait analysis in the orthopaedic management of ambulatory cerebral palsy. Curr Opin Pediatr. 2007, 19:38-43. 10.1097\/MOP.0b013e3280118a6d","journal-title":"Curr Opin Pediatr"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1016\/j.gaitpost.2010.11.025","article-title":"Video gait analysis for ambulatory children with cerebral palsy: why, when, where and how!","volume":"33","author":"Harvey A","year":"2011","unstructured":"Harvey A, Gorter JW. Video gait analysis for ambulatory children with cerebral palsy: why, when, where and how!. Gait Posture. 2011, 33:501-3. 10.1016\/j.gaitpost.2010.11.025","journal-title":"Gait Posture"},{"key":"ref12","unstructured":"Virtual tech makes recovery a reality at Walter Reed. (2009). Accessed. 6\/27\/2025: https:\/\/www.army.mil\/article\/28986\/virtual_tech_makes_recovery_a_reality_at_walter_reed."},{"key":"ref13","unstructured":"Motion Lab Systems I. (2023). Accessed. 6\/27\/2025: https:\/\/www.researchgate.net\/profile\/Wagner-De-Godoy\/post\/Kindly_inquire_about_suggestion_for_gait_and_posture_lab\/at...."},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2004.02.047","article-title":"Quantification of human motion: gait analysis-benefits and limitations to its application to clinical problems","volume":"37","author":"Simon SR","year":"2004","unstructured":"Simon SR. Quantification of human motion: gait analysis-benefits and limitations to its application to clinical problems. J Biomech. 2004, 37:1869-80. 10.1016\/j.jbiomech.2004.02.047","journal-title":"J Biomech"},{"key":"ref15","unstructured":"Veterans in Rural America. 2011-2015 American Community Survey Reports. (2017). Accessed: 6\/27\/2025: https:\/\/www.census.gov\/content\/dam\/Census\/library\/publications\/2017\/acs\/acs-36.pdf."},{"key":"ref16","doi-asserted-by":"publisher","DOI":"10.1016\/j.medengphy.2017.01.002","article-title":"Dynamic assessment of center of pressure measurements from an instrumented AMTI treadmill with controlled precision","volume":"42","author":"Fortune E","year":"2017","unstructured":"Fortune E, Crenshaw J, Lugade V, Kaufman KR. Dynamic assessment of center of pressure measurements from an instrumented AMTI treadmill with controlled precision. Med Eng Phys. 2017, 42:99-104. 10.1016\/j.medengphy.2017.01.002","journal-title":"Med Eng Phys"},{"key":"ref17","doi-asserted-by":"publisher","DOI":"10.1016\/j.gaitpost.2015.02.020","article-title":"Lower limb control and strength in runners with and without patellofemoral pain syndrome","volume":"41","author":"Esculier JF","year":"2015","unstructured":"Esculier JF, Roy JS, Bouyer LJ. Lower limb control and strength in runners with and without patellofemoral pain syndrome. Gait Posture. 2015, 41:813-9. 10.1016\/j.gaitpost.2015.02.020","journal-title":"Gait Posture"},{"key":"ref18","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0278444","article-title":"Anxiety state impact on recovery of runners with lower extremity injuries","volume":"17","author":"Madsen A","year":"2022","unstructured":"Madsen A, Sharififar S, Oberhaus J, Vincent KR, Vincent HK. Anxiety state impact on recovery of runners with lower extremity injuries. PLoS One. 2022, 17:e0278444. 10.1371\/journal.pone.0278444","journal-title":"PLoS One"},{"key":"ref19","doi-asserted-by":"publisher","DOI":"10.1136\/bjsm.2009.069112","article-title":"The effect of real-time gait retraining on hip kinematics, pain and function in subjects with patellofemoral pain syndrome","volume":"45","author":"Noehren B","year":"2011","unstructured":"Noehren B, Scholz J, Davis I. The effect of real-time gait retraining on hip kinematics, pain and function in subjects with patellofemoral pain syndrome. Br J Sports Med. 2011, 45:691-6. 10.1136\/bjsm.2009.069112","journal-title":"Br J Sports Med"},{"key":"ref20","doi-asserted-by":"publisher","DOI":"10.4322\/rbeb.2011.001","article-title":"A vertical ground reaction force-measuring treadmill for the analysis of prosthetic limbs","volume":"27","author":"Bagesteiro LB","year":"2011","unstructured":"Bagesteiro LB, Gould D, Ewins DJ. A vertical ground reaction force-measuring treadmill for the analysis of prosthetic limbs. Revista Brasileira de Engenharia Biom\u00e9dica. 2011, 27:3-11. 10.4322\/rbeb.2011.001","journal-title":"Revista Brasileira de Engenharia Biom\u00e9dica"},{"key":"ref21","doi-asserted-by":"publisher","DOI":"10.1098\/rsif.2011.0877","article-title":"Leg stiffness of sprinters using running-specific prostheses","volume":"9","author":"McGowan CP","year":"2012","unstructured":"McGowan CP, Grabowski AM, McDermott WJ, Herr HM, Kram R. Leg stiffness of sprinters using running-specific prostheses. J R Soc Interface. 2012, 9:1975-82. 10.1098\/rsif.2011.0877","journal-title":"J R Soc Interface"},{"key":"ref22","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0168298","article-title":"Characterizing the mechanical properties of running-specific prostheses","volume":"11","author":"Beck ON","year":"2016","unstructured":"Beck ON, Taboga P, Grabowski AM. Characterizing the mechanical properties of running-specific prostheses. PLoS One. 2016, 11:e0168298. 10.1371\/journal.pone.0168298","journal-title":"PLoS One"},{"key":"ref23","doi-asserted-by":"publisher","DOI":"10.1038\/s41597-020-0494-7","article-title":"A kinematic and kinetic dataset of 18 above-knee amputees walking at various speeds","volume":"7","author":"Hood S","year":"2020","unstructured":"Hood S, Ishmael MK, Gunnell A, Foreman KB, Lenzi T. A kinematic and kinetic dataset of 18 above-knee amputees walking at various speeds. Sci Data. 2020, 7:150. 10.1038\/s41597-020-0494-7","journal-title":"Sci Data"},{"key":"ref24","doi-asserted-by":"publisher","DOI":"10.1016\/j.gaitpost.2018.08.017","article-title":"Test-retest reliability of an instrumented electronic walkway system (GAITRite) for the measurement of spatio-temporal gait parameters in young patients with Friedreich's ataxia","volume":"66","author":"Roche B","year":"2018","unstructured":"Roche B, Simon AL, Guilmin-Cr\u00e9pon S, et al.. Test-retest reliability of an instrumented electronic walkway system (GAITRite) for the measurement of spatio-temporal gait parameters in young patients with Friedreich's ataxia. Gait Posture. 2018, 66:45-50. 10.1016\/j.gaitpost.2018.08.017","journal-title":"Gait Posture"},{"key":"ref25","doi-asserted-by":"publisher","DOI":"10.1016\/j.gaitpost.2004.10.005","article-title":"Validity of the GAITRite walkway system for the measurement of averaged and individual step parameters of gait","volume":"22","author":"Webster KE","year":"2005","unstructured":"Webster KE, Wittwer JE, Feller JA. Validity of the GAITRite walkway system for the measurement of averaged and individual step parameters of gait. Gait Posture. 2005, 22:317-21. 10.1016\/j.gaitpost.2004.10.005","journal-title":"Gait Posture"},{"key":"ref26","doi-asserted-by":"publisher","DOI":"10.1097\/PHM.0b013e3181a5b1ec","article-title":"Agreement between temporospatial gait parameters of an electronic walkway and a motion capture system in healthy and chronic stroke populations","volume":"88","author":"Stokic DS","year":"2009","unstructured":"Stokic DS, Horn TS, Ramshur JM, Chow JW. Agreement between temporospatial gait parameters of an electronic walkway and a motion capture system in healthy and chronic stroke populations. Am J Phys Med Rehabil. 2009, 88:437-44. 10.1097\/PHM.0b013e3181a5b1ec","journal-title":"Am J Phys Med Rehabil"},{"key":"ref27","doi-asserted-by":"publisher","DOI":"10.1682\/JRRD.2015.03.0038","article-title":"Explaining modified 2-min walk test outcomes in male Veterans with traumatic or nontraumatic lower-limb amputation","volume":"53","author":"Loyd BJ","year":"2016","unstructured":"Loyd BJ, Fields TT, Stephenson RO, Stevens-Lapsley J, Christiansen CL. Explaining modified 2-min walk test outcomes in male Veterans with traumatic or nontraumatic lower-limb amputation. J Rehabil Res Dev. 2016, 53:1035-44. 10.1682\/JRRD.2015.03.0038","journal-title":"J Rehabil Res Dev"},{"key":"ref28","doi-asserted-by":"publisher","DOI":"10.1080\/09593985.2021.1990449","article-title":"Gait asymmetry is associated with performance-based physical function among adults with lower-limb amputation","volume":"38","author":"Seth M","year":"2022","unstructured":"Seth M, Coyle PC, Pohlig RT, Beisheim EH, Horne JR, Hicks GE, Sions JM. Gait asymmetry is associated with performance-based physical function among adults with lower-limb amputation. Physiother Theory Pract. 2022, 38:3108-18. 10.1080\/09593985.2021.1990449","journal-title":"Physiother Theory Pract"},{"key":"ref29","doi-asserted-by":"publisher","DOI":"10.1016\/j.gaitpost.2012.07.029","article-title":"Gait variability and regularity of people with transtibial amputations","volume":"37","author":"Parker K","year":"2013","unstructured":"Parker K, Hanada E, Adderson J. Gait variability and regularity of people with transtibial amputations. Gait Posture. 2013, 37:269-73. 10.1016\/j.gaitpost.2012.07.029","journal-title":"Gait Posture"},{"key":"ref30","doi-asserted-by":"publisher","DOI":"10.1097\/JPO.0b013e3181cc0e34","article-title":"Differences in the spatiotemporal parameters of transtibial and transfemoral amputee gait","volume":"22","author":"Highsmith MJ","year":"2010","unstructured":"Highsmith MJ, Schulz BW, Hart-Hughes S, Latlief GA, Phillips SL. Differences in the spatiotemporal parameters of transtibial and transfemoral amputee gait. J Prosthet Orthot. 2010, 22:26-30. 10.1097\/JPO.0b013e3181cc0e34","journal-title":"J Prosthet Orthot"},{"key":"ref31","doi-asserted-by":"publisher","DOI":"10.1016\/j.gaitpost.2016.12.023","article-title":"Reliability and validity of the protokinetics movement analysis software in measuring center of pressure during walking","volume":"52","author":"Lynall RC","year":"2017","unstructured":"Lynall RC, Zukowski LA, Plummer P, Mihalik JP. Reliability and validity of the protokinetics movement analysis software in measuring center of pressure during walking. Gait Posture. 2017, 52:308-11. 10.1016\/j.gaitpost.2016.12.023","journal-title":"Gait Posture"},{"key":"ref32","doi-asserted-by":"publisher","DOI":"10.1097\/PXR.0000000000000417","article-title":"Spatiotemporal gait parameters influencing functional mobility of people with lower limb amputation","author":"Kristal A","year":"2025","unstructured":"Kristal A, Gaunaurd I, Kirk-Sanchez N, et al.. Spatiotemporal gait parameters influencing functional mobility of people with lower limb amputation. Prosthet Orthot Int. 2025, 10.1097\/PXR.0000000000000417","journal-title":"Prosthet Orthot Int"},{"key":"ref33","doi-asserted-by":"publisher","DOI":"10.1016\/j.gaitpost.2018.05.016","article-title":"Temporal-spatial values during a 180\u00b0 step turn in people with unilateral lower limb amputation","volume":"63","author":"Clemens SM","year":"2018","unstructured":"Clemens SM, Klute GK, Kirk-Sanchez NJ, Raya MA, Kim KJ, Gaunaurd IA, Gailey RS. Temporal-spatial values during a 180\u00b0 step turn in people with unilateral lower limb amputation. Gait Posture. 2018, 63:276-81. 10.1016\/j.gaitpost.2018.05.016","journal-title":"Gait Posture"},{"key":"ref34","doi-asserted-by":"publisher","DOI":"10.1097\/PXR.0000000000000013","article-title":"Effect of transfemoral prosthetic socket interface design on gait, balance, mobility, and preference: a randomized clinical trial","volume":"45","author":"Kahle JT","year":"2021","unstructured":"Kahle JT, Miro RM, Ho LT, et al.. Effect of transfemoral prosthetic socket interface design on gait, balance, mobility, and preference: a randomized clinical trial. Prosthet Orthot Int. 2021, 45:304-12. 10.1097\/PXR.0000000000000013","journal-title":"Prosthet Orthot Int"},{"key":"ref35","doi-asserted-by":"publisher","DOI":"10.3390\/s140406891","article-title":"IMU-based joint angle measurement for gait analysis","volume":"14","author":"Seel T","year":"2014","unstructured":"Seel T, Raisch J, Schauer T. IMU-based joint angle measurement for gait analysis. Sensors (Basel). 2014, 14:6891-909. 10.3390\/s140406891","journal-title":"Sensors (Basel)"},{"key":"ref36","doi-asserted-by":"publisher","DOI":"10.1007\/s11517-019-02098-4","article-title":"Gait event detection using inertial measurement units in people with transfemoral amputation: a comparative study","volume":"58","author":"Simonetti E","year":"2020","unstructured":"Simonetti E, Villa C, Bascou J, Vannozzi G, Bergamini E, Pillet H. Gait event detection using inertial measurement units in people with transfemoral amputation: a comparative study. Med Biol Eng Comput. 2020, 58:461-70. 10.1007\/s11517-019-02098-4","journal-title":"Med Biol Eng Comput"},{"key":"ref37","doi-asserted-by":"publisher","DOI":"10.1016\/j.gaitpost.2018.05.025","article-title":"IMU-based gait analysis in lower limb prosthesis users: comparison of step demarcation algorithms","volume":"64","author":"Bastas G","year":"2018","unstructured":"Bastas G, Fleck JJ, Peters RA, Zelik KE. IMU-based gait analysis in lower limb prosthesis users: comparison of step demarcation algorithms. Gait Posture. 2018, 64:30-7. 10.1016\/j.gaitpost.2018.05.025","journal-title":"Gait Posture"},{"key":"ref38","doi-asserted-by":"publisher","DOI":"10.1016\/j.gaitpost.2016.08.012","article-title":"Gait event detection in laboratory and real life settings: accuracy of ankle and waist sensor based methods","volume":"50","author":"Storm FA","year":"2016","unstructured":"Storm FA, Buckley CJ, Mazz\u00e0 C. Gait event detection in laboratory and real life settings: accuracy of ankle and waist sensor based methods. Gait Posture. 2016, 50:42-6. 10.1016\/j.gaitpost.2016.08.012","journal-title":"Gait Posture"},{"key":"ref39","doi-asserted-by":"publisher","DOI":"10.1682\/JRRD.2007.12.0209","article-title":"Validity of DynaPort GaitMonitor for assessment of spatiotemporal parameters in amputee gait","volume":"45","author":"Houdijk H","year":"2008","unstructured":"Houdijk H, Appelman FM, Van Velzen JM, Van der Woude LHV, Van Bennekom CAM. Validity of DynaPort GaitMonitor for assessment of spatiotemporal parameters in amputee gait. J Rehabil Res Dev. 2008, 45:1335-42. 10.1682\/JRRD.2007.12.0209","journal-title":"J Rehabil Res Dev"},{"key":"ref40","doi-asserted-by":"publisher","DOI":"10.3390\/s23031738","article-title":"Validity and reliability of inertial measurement unit (IMU)-derived 3D joint kinematics in persons wearing transtibial prosthesis","volume":"23","author":"Rattanakoch J","year":"2023","unstructured":"Rattanakoch J, Samala M, Limroongreungrat W, et al.. Validity and reliability of inertial measurement unit (IMU)-derived 3D joint kinematics in persons wearing transtibial prosthesis. Sensors (Basel). 2023, 23:10.3390\/s23031738","journal-title":"Sensors (Basel)"},{"key":"ref41","doi-asserted-by":"publisher","DOI":"10.1016\/j.gaitpost.2019.05.022","article-title":"Evolution of gait parameters in individuals with a lower-limb amputation during a six-minute walk test","volume":"72","author":"Beausoleil S","year":"2019","unstructured":"Beausoleil S, Miramand L, Turcot K. Evolution of gait parameters in individuals with a lower-limb amputation during a six-minute walk test. Gait Posture. 2019, 72:40-5. 10.1016\/j.gaitpost.2019.05.022","journal-title":"Gait Posture"},{"key":"ref42","doi-asserted-by":"publisher","DOI":"10.1016\/j.gaitpost.2017.04.013","article-title":"Validity and repeatability of inertial measurement units for measuring gait parameters","volume":"55","author":"Washabaugh EP","year":"2017","unstructured":"Washabaugh EP, Kalyanaraman T, Adamczyk PG, Claflin ES, Krishnan C. Validity and repeatability of inertial measurement units for measuring gait parameters. Gait Posture. 2017, 55:87-93. 10.1016\/j.gaitpost.2017.04.013","journal-title":"Gait Posture"},{"key":"ref43","doi-asserted-by":"publisher","DOI":"10.1097\/JPO.0000000000000332","article-title":"The feasibility and validity of a wearable sensor system to assess the stability of high-functioning lower-limb prosthesis users","volume":"Online first","author":"Miller KT","year":"2020","unstructured":"Miller KT, Russell M, Jenks T, et al.. The feasibility and validity of a wearable sensor system to assess the stability of high-functioning lower-limb prosthesis users. J Prosthet Orthot. 2020, Online first:10.1097\/JPO.0000000000000332","journal-title":"J Prosthet Orthot"},{"key":"ref44","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2017.02.016","article-title":"The development and concurrent validity of a real-time algorithm for temporal gait analysis using inertial measurement units","volume":"55","author":"Allseits E","year":"2017","unstructured":"Allseits E, Lu\u010darevi\u0107 J, Gailey R, Agrawal V, Gaunaurd I, Bennett C. The development and concurrent validity of a real-time algorithm for temporal gait analysis using inertial measurement units. J Biomech. 2017, 55:27-33. 10.1016\/j.jbiomech.2017.02.016","journal-title":"J Biomech"},{"key":"ref45","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2017.11.010","article-title":"A practical step length algorithm using lower limb angular velocities","volume":"66","author":"Allseits E","year":"2018","unstructured":"Allseits E, Agrawal V, Lu\u010darevi\u0107 J, Gailey R, Gaunaurd I, Bennett C. A practical step length algorithm using lower limb angular velocities. J Biomech. 2018, 66:137-44. 10.1016\/j.jbiomech.2017.11.010","journal-title":"J Biomech"},{"key":"ref46","doi-asserted-by":"publisher","DOI":"10.1016\/j.clinbiomech.2019.12.007","article-title":"Inertial sensor-based measures of gait symmetry and repeatability in people with unilateral lower limb amputation","volume":"72","author":"Clemens S","year":"2020","unstructured":"Clemens S, Kim KJ, Gailey R, Kirk-Sanchez N, Kristal A, Gaunaurd I. Inertial sensor-based measures of gait symmetry and repeatability in people with unilateral lower limb amputation. Clin Biomech (Bristol). 2020, 72:102-7. 10.1016\/j.clinbiomech.2019.12.007","journal-title":"Clin Biomech (Bristol)"},{"key":"ref47","doi-asserted-by":"publisher","DOI":"10.1093\/milmed\/usz201","article-title":"The effectiveness of the DoD\/VA mobile device outcomes-based rehabilitation program for high functioning service members and veterans with lower limb amputation","volume":"185","author":"Gaunaurd I","year":"2020","unstructured":"Gaunaurd I, Gailey R, Springer B, et al.. The effectiveness of the DoD\/VA mobile device outcomes-based rehabilitation program for high functioning service members and veterans with lower limb amputation. Mil Med. 2020, 185:480-9. 10.1093\/milmed\/usz201","journal-title":"Mil Med"},{"key":"ref48","doi-asserted-by":"publisher","DOI":"10.1093\/milmed\/usaa428","article-title":"Usability assessment of the rehabilitation lower-limb orthopedic assistive device by service members and veterans with lower limb loss","volume":"186","author":"Symsack A","year":"2021","unstructured":"Symsack A, Gaunaurd I, Thaper A, et al.. Usability assessment of the rehabilitation lower-limb orthopedic assistive device by service members and veterans with lower limb loss. Mil Med. 2021, 186:379-86. 10.1093\/milmed\/usaa428","journal-title":"Mil Med"},{"key":"ref49","doi-asserted-by":"publisher","DOI":"10.7717\/peerj.12995","article-title":"Applications and limitations of current markerless motion capture methods for clinical gait biomechanics","volume":"10","author":"Wade L","year":"2022","unstructured":"Wade L, Needham L, McGuigan P, Bilzon J. Applications and limitations of current markerless motion capture methods for clinical gait biomechanics. PeerJ. 2022, 10:e12995. 10.7717\/peerj.12995","journal-title":"PeerJ"},{"key":"ref50","doi-asserted-by":"publisher","DOI":"10.1016\/j.gaitpost.2016.10.001","article-title":"Improved kinect-based spatiotemporal and kinematic treadmill gait assessment","volume":"51","author":"Eltoukhy M","year":"2017","unstructured":"Eltoukhy M, Oh J, Kuenze C, Signorile J. Improved kinect-based spatiotemporal and kinematic treadmill gait assessment. Gait Posture. 2017, 51:77-83. 10.1016\/j.gaitpost.2016.10.001","journal-title":"Gait Posture"},{"key":"ref51","doi-asserted-by":"publisher","DOI":"10.1016\/j.gaitpost.2016.08.022","article-title":"Validity and sensitivity of the longitudinal asymmetry index to detect gait asymmetry using Microsoft Kinect data","volume":"51","author":"Auvinet E","year":"2017","unstructured":"Auvinet E, Multon F, Manning V, Meunier J, Cobb JP. Validity and sensitivity of the longitudinal asymmetry index to detect gait asymmetry using Microsoft Kinect data. Gait Posture. 2017, 51:162-8. 10.1016\/j.gaitpost.2016.08.022","journal-title":"Gait Posture"},{"key":"ref52","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0166532","article-title":"Accuracy and reliability of the Kinect version 2 for clinical measurement of motor function","volume":"11","author":"Otte K","year":"2016","unstructured":"Otte K, Kayser B, Mansow-Model S, Verrel J, Paul F, Brandt AU, Schmitz-H\u00fcbsch T. Accuracy and reliability of the Kinect version 2 for clinical measurement of motor function. PLoS One. 2016, 11:e0166532. 10.1371\/journal.pone.0166532","journal-title":"PLoS One"},{"key":"ref53","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2018.01.008","article-title":"An instrumental approach for monitoring physical exercises in a visual markerless scenario: a proof of concept","volume":"69","author":"Capecci M","year":"2018","unstructured":"Capecci M, Ceravolo MG, Ferracuti F, et al.. An instrumental approach for monitoring physical exercises in a visual markerless scenario: a proof of concept. J Biomech. 2018, 69:70-80. 10.1016\/j.jbiomech.2018.01.008","journal-title":"J Biomech"},{"key":"ref54","doi-asserted-by":"publisher","DOI":"10.1016\/j.gaitpost.2022.07.067","article-title":"Markerless versus marker-based motion analysis in subjects with lower limb amputation: a case series","volume":"97","author":"Heitzmann D","year":"2022","unstructured":"Heitzmann D, Rist V, Block J, Alimusaj M, Wolf S. Markerless versus marker-based motion analysis in subjects with lower limb amputation: a case series. Gait Posture. 2022, 97:95-6. 10.1016\/j.gaitpost.2022.07.067","journal-title":"Gait Posture"}],"container-title":["Cureus"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cureus.com\/articles\/388630-integrating-gait-analysis-systems-in-clinical-rehabilitation-settings-for-individuals-with-lower-limb-amputation-a-narrative-review","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,8,26]],"date-time":"2025-08-26T14:50:01Z","timestamp":1756219801000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cureus.com\/articles\/388630-integrating-gait-analysis-systems-in-clinical-rehabilitation-settings-for-individuals-with-lower-limb-amputation-a-narrative-review"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,8,26]]},"references-count":54,"URL":"https:\/\/doi.org\/10.7759\/cureus.91030","relation":{},"ISSN":["2168-8184"],"issn-type":[{"value":"2168-8184","type":"print"}],"subject":[],"published":{"date-parts":[[2025,8,26]]}}}