{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,9,11]],"date-time":"2025-09-11T17:40:52Z","timestamp":1757612452269,"version":"3.44.0"},"reference-count":12,"publisher":"Springer Science and Business Media LLC","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2025,9,4]]},"DOI":"10.7759\/cureus.91601","type":"journal-article","created":{"date-parts":[[2025,9,4]],"date-time":"2025-09-04T13:46:00Z","timestamp":1756993560000},"source":"Crossref","is-referenced-by-count":0,"title":["Intraprocedural Acute Stent Thrombosis of Unusual Etiology"],"prefix":"10.7759","author":[{"given":"Binayendu","family":"Prakash","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tapan","family":"Kumar","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sritam","family":"Acharya","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mandar M","family":"Shah","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.15420\/icr.2018.17.2","article-title":"OCT-guided percutaneous coronary intervention in bifurcation lesions","volume":"14","author":"Longobardo L","year":"2019","unstructured":"Longobardo L, Mattesini A, Valente S, Di Mario C. OCT-guided percutaneous coronary intervention in bifurcation lesions. Interv Cardiol. 2019, 14:5-9. 10.15420\/icr.2018.17.2","journal-title":"Interv Cardiol"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.7759\/cureus.3720","article-title":"Ticagrelor-induced angioedema after percutaneous coronary intervention in a patient with a history of ischemic stroke and low response to clopidogrel: a rare dilemma","volume":"10","author":"Piranavan P","year":"2018","unstructured":"Piranavan P, Kaur NJ, Marmoush F, et al.. Ticagrelor-induced angioedema after percutaneous coronary intervention in a patient with a history of ischemic stroke and low response to clopidogrel: a rare dilemma. Cureus. 2018, 10:e3720. 10.7759\/cureus.3720","journal-title":"Cureus"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1016\/j.jjcc.2019.02.007","article-title":"The Glasgow prognostic score as a significant predictor of clinical outcomes in patients with acute coronary syndrome","volume":"74","author":"Lee SN","year":"2019","unstructured":"Lee SN, Moon D, Moon KW, Yoo KD. The Glasgow prognostic score as a significant predictor of clinical outcomes in patients with acute coronary syndrome. J Cardiol. 2019, 74:130-5. 10.1016\/j.jjcc.2019.02.007","journal-title":"J Cardiol"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcin.2011.01.011","article-title":"Autopsy validation study of the academic research consortium stent thrombosis definition","volume":"4","author":"Cutlip DE","year":"2011","unstructured":"Cutlip DE, Nakazawa G, Krucoff MW, et al.. Autopsy validation study of the academic research consortium stent thrombosis definition. JACC Cardiovasc Interv. 2011, 4:554-9. 10.1016\/j.jcin.2011.01.011","journal-title":"JACC Cardiovasc Interv"},{"key":"ref5","article-title":"[Meta-analysis on safety and efficacy of dual antiplatelet therapy combining with proton pump inhibitors for patients after percutaneous coronary intervention]","volume":"47","author":"Che QQ","year":"2019","unstructured":"Che QQ, Wu Q, Liang YB, et al.. [Meta-analysis on safety and efficacy of dual antiplatelet therapy combining with proton pump inhibitors for patients after percutaneous coronary intervention]. Zhonghua Xin Xue Guan Bing Za Zhi. 2019, 47:129-40.","journal-title":"Zhonghua Xin Xue Guan Bing Za Zhi"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1161\/01.cir.95.6.1549","article-title":"Experimental study of thrombogenicity and foreign body reaction induced by heparin-coated coronary stents","volume":"95","author":"De Scheerder I","year":"1997","unstructured":"De Scheerder I, Wang K, Wilczek K, et al.. Experimental study of thrombogenicity and foreign body reaction induced by heparin-coated coronary stents. Circulation. 1997, 95:1549-53. 10.1161\/01.cir.95.6.1549","journal-title":"Circulation"},{"key":"ref7","article-title":"Stent Thrombosis","author":"Modi K","year":"2025","unstructured":"Modi K, Soos MP, Mahajan K. Stent Thrombosis. StatPearls, Treasure Island, FL; 2025."},{"key":"ref8","article-title":"Foreign body contamination during stent implantation","volume":"40","author":"Whelan DM","year":"1997","unstructured":"Whelan DM, van Beusekom HM, van der Giessen WJ. Foreign body contamination during stent implantation. Catheter Cardiovasc Diagn. 1997, 40:328-32.","journal-title":"Catheter Cardiovasc Diagn"},{"key":"ref9","article-title":"Foreign body contamination during interventional procedures","author":"Laird JR","year":"2012","unstructured":"Laird JR, Cavros N, Gallino R, et al.. Foreign body contamination during interventional procedures. Endovasc Today. 2012,","journal-title":"Endovasc Today"},{"key":"ref10","article-title":"Cotton fiber contamination in the sterile field: the operating room & the interventional labs","author":"Furbush NC","year":"2011","unstructured":"Furbush NC . Cotton fiber contamination in the sterile field: the operating room &amp; the interventional labs. Syntervention Inc. 2011,","journal-title":"Syntervention Inc"},{"key":"ref11","article-title":"Inadvertent foreign body embolization in diagnostic and therapeutic cerebral angiography","volume":"27","author":"Shannon P","year":"2006","unstructured":"Shannon P, Billbao JM, Marotta T, Terbrugge K. Inadvertent foreign body embolization in diagnostic and therapeutic cerebral angiography. AJNR Am J Neuroradiol. 2006, 27:278-82.","journal-title":"AJNR Am J Neuroradiol"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.20541","article-title":"Coronary embolization of a gauze fragment: a cautionary case report","volume":"66","author":"Fischi M","year":"2005","unstructured":"Fischi M, Narins CR. Coronary embolization of a gauze fragment: a cautionary case report. Catheter Cardiovasc Interv. 2005, 66:570-2. 10.1002\/ccd.20541","journal-title":"Catheter Cardiovasc Interv"}],"container-title":["Cureus"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cureus.com\/articles\/330856-intraprocedural-acute-stent-thrombosis-of-unusual-etiology","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,9,4]],"date-time":"2025-09-04T13:46:01Z","timestamp":1756993561000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cureus.com\/articles\/330856-intraprocedural-acute-stent-thrombosis-of-unusual-etiology"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,9,4]]},"references-count":12,"URL":"https:\/\/doi.org\/10.7759\/cureus.91601","relation":{},"ISSN":["2168-8184"],"issn-type":[{"type":"print","value":"2168-8184"}],"subject":[],"published":{"date-parts":[[2025,9,4]]}}}