{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,9,11]],"date-time":"2025-09-11T19:03:01Z","timestamp":1757617381185,"version":"3.44.0"},"reference-count":17,"publisher":"Springer Science and Business Media LLC","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2025,9,5]]},"DOI":"10.7759\/cureus.91688","type":"journal-article","created":{"date-parts":[[2025,9,6]],"date-time":"2025-09-06T02:46:14Z","timestamp":1757126774000},"source":"Crossref","is-referenced-by-count":0,"title":["Contact of Teeth With Blades of Macintosh Laryngoscope, McGrath MAC\u00ae Video Laryngoscope, and Pentax-AWS Airway Scope\u00ae During Tracheal Intubation: A Randomized Crossover Simulation Study"],"prefix":"10.7759","author":[{"given":"Noriya","family":"Hirose","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Miki","family":"Matsui","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tomoaki","family":"Itaya","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Keisuke","family":"Nakazawa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shunichi","family":"Takagi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takahiro","family":"Suzuki","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1097\/00000542-199905000-00013","article-title":"Perianesthetic dental injuries: frequency, outcomes, and risk factors","volume":"90","author":"Warner ME","year":"1999","unstructured":"Warner ME, Benenfeld SM, Warner MA, Schroeder DR, Maxson PM. Perianesthetic dental injuries: frequency, outcomes, and risk factors. Anesthesiology. 1999, 90:1302-5. 10.1097\/00000542-199905000-00013","journal-title":"Anesthesiology"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1177\/0310057X0002800202","article-title":"Dental trauma associated with anaesthesia","volume":"28","author":"Owen H","year":"2000","unstructured":"Owen H, Waddell-Smith I. Dental trauma associated with anaesthesia. Anaesth Intensive Care. 2000, 28:133-45. 10.1177\/0310057X0002800202","journal-title":"Anaesth Intensive Care"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1016\/j.jclinane.2007.02.007","article-title":"Dental injury associated with anesthesia: a report of 161,687 anesthetics given over 14 years","volume":"19","author":"Newland MC","year":"2007","unstructured":"Newland MC, Ellis SJ, Peters KR, Simonson JA, Durham TM, Ullrich FA, Tinker JH. Dental injury associated with anesthesia: a report of 161,687 anesthetics given over 14 years. J Clin Anesth. 2007, 19:339-45. 10.1016\/j.jclinane.2007.02.007","journal-title":"J Clin Anesth"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-9657.2008.00670.x","article-title":"Dental injuries resulting from tracheal intubation - a retrospective study","volume":"25","author":"Vogel J","year":"2009","unstructured":"Vogel J, St\u00fcbinger S, Kaufmann M, Krastl G, Filippi A. Dental injuries resulting from tracheal intubation - a retrospective study. Dent Traumatol. 2009, 25:73-7. 10.1111\/j.1600-9657.2008.00670.x","journal-title":"Dent Traumatol"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1111\/anae.12342","article-title":"Dental injury after conventional direct laryngoscopy: a prospective observational study","volume":"68","author":"Mour\u00e3o J","year":"2013","unstructured":"Mour\u00e3o J, Neto J, Lu\u00eds C, Moreno C, Barbosa J, Carvalho J, Tavares J. Dental injury after conventional direct laryngoscopy: a prospective observational study. Anaesthesia. 2013, 68:1059-65. 10.1111\/anae.12342","journal-title":"Anaesthesia"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajoms.2017.06.010","article-title":"Dental injuries caused by endotracheal intubation - a retrospective study","volume":"29","author":"Kakei Y","year":"2017","unstructured":"Kakei Y, Akashi M, Kashin M, Komori S, Komori T. Dental injuries caused by endotracheal intubation - a retrospective study. J Oral Maxillofac Surg Med Pathol. 2017, 29:518-21. 10.1016\/j.ajoms.2017.06.010","journal-title":"J Oral Maxillofac Surg Med Pathol"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1111\/j.1399-6576.2011.02541.x","article-title":"Forces applied to the maxillary incisors by video laryngoscopes and the Macintosh laryngoscope","volume":"56","author":"Lee RA","year":"2012","unstructured":"Lee RA, van Zundert AA, Maassen RL, Wieringa PA. Forces applied to the maxillary incisors by video laryngoscopes and the Macintosh laryngoscope. Acta Anaesthesiol Scand. 2012, 56:224-9. 10.1111\/j.1399-6576.2011.02541.x","journal-title":"Acta Anaesthesiol Scand"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1097\/MEJ.0000000000000716","article-title":"Forces applied to maxillary incisors with different laryngoscopes","volume":"27","author":"Hanoglu DN","year":"2020","unstructured":"Hanoglu DN, Goksu E, Kazanir S, Chebl RB. Forces applied to maxillary incisors with different laryngoscopes. Eur J Emerg Med. 2020, 27:384-5. 10.1097\/MEJ.0000000000000716","journal-title":"Eur J Emerg Med"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.1046\/j.0305-182x.2003.01179.x","article-title":"Single tooth bite forces in healthy young adults","volume":"31","author":"Ferrario VF","year":"2004","unstructured":"Ferrario VF, Sforza C, Serrao G, Dellavia C, Tartaglia GM. Single tooth bite forces in healthy young adults. J Oral Rehabil. 2004, 31:18-22. 10.1046\/j.0305-182x.2003.01179.x","journal-title":"J Oral Rehabil"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.1002\/14651858.CD011136.pub3","article-title":"Videolaryngoscopy versus direct laryngoscopy for adults undergoing tracheal intubation","volume":"4","author":"Hansel J","year":"2022","unstructured":"Hansel J, Rogers AM, Lewis SR, Cook TM, Smith AF. Videolaryngoscopy versus direct laryngoscopy for adults undergoing tracheal intubation. Cochrane Database Syst Rev. 2022, 4:CD011136. 10.1002\/14651858.CD011136.pub3","journal-title":"Cochrane Database Syst Rev"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1111\/anae.12705","article-title":"Pentax Airway Scope\u00ae vs Macintosh laryngoscope for tracheal intubation in adult patients: a systematic review and meta-analysis","volume":"69","author":"Hoshijima H","year":"2014","unstructured":"Hoshijima H, Kuratani N, Hirabayashi Y, Takeuchi R, Shiga T, Masaki E. Pentax Airway Scope\u00ae vs Macintosh laryngoscope for tracheal intubation in adult patients: a systematic review and meta-analysis. Anaesthesia. 2014, 69:911-8. 10.1111\/anae.12705","journal-title":"Anaesthesia"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1111\/aas.13368","article-title":"Comparison of Pentax Airway Scope and Macintosh laryngoscope for orotracheal intubation in children: a randomised non-inferiority trial","volume":"63","author":"Yi IK","year":"2019","unstructured":"Yi IK, Kwak HJ, Kim KM, Ahn SH, Lee SY, Kim JY. Comparison of Pentax Airway Scope and Macintosh laryngoscope for orotracheal intubation in children: a randomised non-inferiority trial. Acta Anaesthesiol Scand. 2019, 63:853-8. 10.1111\/aas.13368","journal-title":"Acta Anaesthesiol Scand"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1136\/emj.2006.045013","article-title":"Airway Scope versus Macintosh laryngoscope: a manikin study","volume":"24","author":"Hirabayashi Y","year":"2007","unstructured":"Hirabayashi Y. Airway Scope versus Macintosh laryngoscope: a manikin study. Emerg Med J. 2007, 24:357-8. 10.1136\/emj.2006.045013","journal-title":"Emerg Med J"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.2344\/anpr-65-03-01","article-title":"Comparison of the contact force exerted on teeth by conventional Macintosh laryngoscope versus video laryngoscopes","volume":"65","author":"Kato Y","year":"2018","unstructured":"Kato Y, Sakuma Y, Momota Y. Comparison of the contact force exerted on teeth by conventional Macintosh laryngoscope versus video laryngoscopes. Anesth Prog. 2018, 65:151-5. 10.2344\/anpr-65-03-01","journal-title":"Anesth Prog"},{"key":"ref15","doi-asserted-by":"publisher","DOI":"10.1111\/anae.13560","article-title":"Risk factors for peri-anaesthetic dental injury","volume":"71","author":"Ham SY","year":"2016","unstructured":"Ham SY, Kim J, Oh YJ, Lee B, Shin YS, Na S. Risk factors for peri-anaesthetic dental injury. Anaesthesia. 2016, 71:1070-6. 10.1111\/anae.13560","journal-title":"Anaesthesia"},{"key":"ref16","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-025-85573-3","article-title":"Incidence of oral complications during endotracheal intubation in general anesthesia among hospitalized children","volume":"15","author":"Al-Shiekh MN","year":"2025","unstructured":"Al-Shiekh MN, Altinawi M, Karkoutly M. Incidence of oral complications during endotracheal intubation in general anesthesia among hospitalized children. Sci Rep. 2025, 15:830. 10.1038\/s41598-025-85573-3","journal-title":"Sci Rep"},{"key":"ref17","doi-asserted-by":"publisher","DOI":"10.1213\/ane.0b013e31819d1db5","article-title":"Perioperative dental considerations for the anesthesiologist","volume":"108","author":"Yasny JS","year":"2009","unstructured":"Yasny JS. Perioperative dental considerations for the anesthesiologist. Anesth Analg. 2009, 108:1564-73. 10.1213\/ane.0b013e31819d1db5","journal-title":"Anesth Analg"}],"container-title":["Cureus"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cureus.com\/articles\/404082-contact-of-teeth-with-blades-of-macintosh-laryngoscope-mcgrath-mac-video-laryngoscope-and-pentax-aws-airway-scope-during-tracheal-intubation-a-randomized-crossover-simulation-study","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,9,6]],"date-time":"2025-09-06T02:46:19Z","timestamp":1757126779000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cureus.com\/articles\/404082-contact-of-teeth-with-blades-of-macintosh-laryngoscope-mcgrath-mac-video-laryngoscope-and-pentax-aws-airway-scope-during-tracheal-intubation-a-randomized-crossover-simulation-study"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,9,5]]},"references-count":17,"URL":"https:\/\/doi.org\/10.7759\/cureus.91688","relation":{},"ISSN":["2168-8184"],"issn-type":[{"type":"print","value":"2168-8184"}],"subject":[],"published":{"date-parts":[[2025,9,5]]}}}