{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,9,29]],"date-time":"2025-09-29T00:02:45Z","timestamp":1759104165683,"version":"3.44.0"},"reference-count":13,"publisher":"Springer Science and Business Media LLC","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2025,9,28]]},"DOI":"10.7759\/cureus.93383","type":"journal-article","created":{"date-parts":[[2025,9,28]],"date-time":"2025-09-28T07:16:37Z","timestamp":1759043797000},"source":"Crossref","is-referenced-by-count":0,"title":["Descemet\u2019s Membrane Detachment Following Inadvertent Intrastromal Injection of an Ophthalmic Viscoelastic Device"],"prefix":"10.7759","author":[{"given":"Adam","family":"Bharmal","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shankar","family":"Ramanathan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Balasubramanian","family":"Ilango","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Abhijit A","family":"Mohite","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1016\/j.survophthal.2019.04.006","article-title":"Ocular hypotony: a comprehensive review","volume":"64","author":"Wang Q","year":"2019","unstructured":"Wang Q, Thau A, Levin AV, Lee D. Ocular hypotony: a comprehensive review. Surv Ophthalmol. 2019, 64:619-38. 10.1016\/j.survophthal.2019.04.006","journal-title":"Surv Ophthalmol"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.2005.072884","article-title":"Safe trabeculectomy technique: long term outcome","volume":"90","author":"Stalmans I","year":"2006","unstructured":"Stalmans I, Gillis A, Lafaut AS, Zeyen T. Safe trabeculectomy technique: long term outcome. Br J Ophthalmol. 2006, 90:44-7. 10.1136\/bjo.2005.072884","journal-title":"Br J Ophthalmol"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1016\/s0002-9394(14)71349-2","article-title":"Ocular hypotony after trabeculectomy with mitomycin C","volume":"116","author":"Zacharia PT","year":"1993","unstructured":"Zacharia PT, Deppermann SR, Schuman JS. Ocular hypotony after trabeculectomy with mitomycin C. Am J Ophthalmol. 1993, 116:314-26. 10.1016\/s0002-9394(14)71349-2","journal-title":"Am J Ophthalmol"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1016\/s0886-3350(01)01092-6","article-title":"Stabilization of flat anterior chamber after trabeculectomy with Healon5","volume":"28","author":"Hoffman RS","year":"2002","unstructured":"Hoffman RS, Fine IH, Packer M. Stabilization of flat anterior chamber after trabeculectomy with Healon5. J Cataract Refract Surg. 2002, 28:712-14. 10.1016\/s0886-3350(01)01092-6","journal-title":"J Cataract Refract Surg"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.2008.143834","article-title":"Treatment of chronic ocular hypotony with intraocular application of sodium hyaluronate","volume":"93","author":"K\u00fc\u00e7\u00fckerd\u00f6nmez C","year":"2009","unstructured":"K\u00fc\u00e7\u00fckerd\u00f6nmez C, Beutel J, Bartz-Schmidt KU, Gelisken F. Treatment of chronic ocular hypotony with intraocular application of sodium hyaluronate. Br J Ophthalmol. 2009, 93:235-9. 10.1136\/bjo.2008.143834","journal-title":"Br J Ophthalmol"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1097\/IJG.0000000000000883","article-title":"Severe intraocular pressure elevation after intracameral Healon5 viscoelastic support for postoperative hypotony after Xen gel stent insertion","volume":"27","author":"Bruynseels A","year":"2018","unstructured":"Bruynseels A, Sii F, Masood I, Shah P. Severe intraocular pressure elevation after intracameral Healon5 viscoelastic support for postoperative hypotony after Xen gel stent insertion. J Glaucoma. 2018, 27:75-6. 10.1097\/IJG.0000000000000883","journal-title":"J Glaucoma"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1097\/ICL.0000000000000378","article-title":"Descemet\u2019s membrane dehiscence resulting from misdirected viscoelastic during anterior chamber reformation","volume":"44 Suppl 1","author":"Chay E","year":"2018","unstructured":"Chay E, Dastgir G, Scott W, Lazzaro D. Descemet\u2019s membrane dehiscence resulting from misdirected viscoelastic during anterior chamber reformation. Eye Contact Lens. 2018, 44 Suppl 1:355-7. 10.1097\/ICL.0000000000000378","journal-title":"Eye Contact Lens"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1159\/000508604","article-title":"Corneal opacification and spontaneous recovery following injection of Healon5 into the corneal stroma during intervention for postoperative hypotony","volume":"11","author":"Massengill M","year":"2020","unstructured":"Massengill M, Blake CR. Corneal opacification and spontaneous recovery following injection of Healon5 into the corneal stroma during intervention for postoperative hypotony. Case Rep Ophthalmol. 2020, 11:263-7. 10.1159\/000508604","journal-title":"Case Rep Ophthalmol"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.3129\/i08-018","article-title":"Descemet membrane detachment following viscoelastic injection for posttrabeculectomy hypotony","volume":"43","author":"Rasouli M","year":"2008","unstructured":"Rasouli M, Mather R, Tingey D. Descemet membrane detachment following viscoelastic injection for posttrabeculectomy hypotony. Can J Ophthalmol. 2008, 43:254-5. 10.3129\/i08-018","journal-title":"Can J Ophthalmol"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.1016\/j.jaapos.2013.07.008","article-title":"Inadvertent intrastromal injection of ophthalmic viscoelastic","volume":"17","author":"McConnell LK","year":"2013","unstructured":"McConnell LK, Winter TW, Olson RJ, Longmuir SQ. Inadvertent intrastromal injection of ophthalmic viscoelastic. J AAPOS. 2013, 17:639-41. 10.1016\/j.jaapos.2013.07.008","journal-title":"J AAPOS"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1016\/s0886-3350(00)00482-x","article-title":"Healon5 viscoadaptive formulation: comparison to Healon and Healon GV","volume":"27","author":"Dick HB","year":"2001","unstructured":"Dick HB, Krummenauer F, Augustin AJ, Pakula T, Pfeiffer N. Healon5 viscoadaptive formulation: comparison to Healon and Healon GV. J Cataract Refract Surg. 2001, 27:320-6. 10.1016\/s0886-3350(00)00482-x","journal-title":"J Cataract Refract Surg"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.1985.01050060065027","article-title":"Descemet's membrane detachment by sodium hyaluronate","volume":"103","author":"Hoover DL","year":"1985","unstructured":"Hoover DL, Giangiacomo J, Benson RL. Descemet's membrane detachment by sodium hyaluronate. Arch Ophthalmol. 1985, 103:805-8. 10.1001\/archopht.1985.01050060065027","journal-title":"Arch Ophthalmol"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1186\/s40662-025-00428-2","article-title":"Iridectomy combined with posterior approach anterior chamber gas injection technique: a novel technique for the treatment of extensive Descemet's membrane detachment","volume":"12","author":"Shen Y","year":"2025","unstructured":"Shen Y, Chen Y, Yin F, Zhang L, Li X, Wu J, Wu M. Iridectomy combined with posterior approach anterior chamber gas injection technique: a novel technique for the treatment of extensive Descemet's membrane detachment. Eye Vis (Lond). 2025, 12:11. 10.1186\/s40662-025-00428-2","journal-title":"Eye Vis (Lond)"}],"container-title":["Cureus"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cureus.com\/articles\/408014-descemets-membrane-detachment-following-inadvertent-intrastromal-injection-of-an-ophthalmic-viscoelastic-device","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,9,28]],"date-time":"2025-09-28T07:16:37Z","timestamp":1759043797000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cureus.com\/articles\/408014-descemets-membrane-detachment-following-inadvertent-intrastromal-injection-of-an-ophthalmic-viscoelastic-device"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,9,28]]},"references-count":13,"URL":"https:\/\/doi.org\/10.7759\/cureus.93383","relation":{},"ISSN":["2168-8184"],"issn-type":[{"value":"2168-8184","type":"print"}],"subject":[],"published":{"date-parts":[[2025,9,28]]}}}