{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,18]],"date-time":"2026-07-18T11:26:32Z","timestamp":1784373992135,"version":"3.55.0"},"reference-count":19,"publisher":"Springer Science and Business Media LLC","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2025,10,6]]},"DOI":"10.7759\/cureus.93939","type":"journal-article","created":{"date-parts":[[2025,10,6]],"date-time":"2025-10-06T16:37:37Z","timestamp":1759768657000},"source":"Crossref","is-referenced-by-count":3,"title":["Functional Outcomes and Patient Satisfaction in Kinematic vs Mechanical Alignment Total Knee Arthroplasty: A Systematic Review"],"prefix":"10.7759","author":[{"given":"Wael A","family":"Rahman","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Khalid Y","family":"Muqri","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hussam M","family":"Suhail","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mohammed M","family":"Shajri","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yazan Z","family":"Omar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mohammed A","family":"Alahmari","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Abdulrhman A","family":"Hakami","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rawan S","family":"Alotaibi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nasser H","family":"Alowaimer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mohammed S","family":"Alrehaili","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.102B1.BJJ-2019-0674.R2","article-title":"Restoring the constitutional alignment with a restrictive kinematic protocol improves quantitative soft-tissue balance in total knee arthroplasty: a randomized controlled trial","volume":"102-B","author":"MacDessi SJ","year":"2020","unstructured":"MacDessi SJ, Griffiths-Jones W, Chen DB, Griffiths-Jones S, Wood JA, Diwan AD, Harris IA. Restoring the constitutional alignment with a restrictive kinematic protocol improves quantitative soft-tissue balance in total knee arthroplasty: a randomized controlled trial. Bone Joint J. 2020, 102-B:117-24. 10.1302\/0301-620X.102B1.BJJ-2019-0674.R2","journal-title":"Bone Joint J"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1002\/ksa.12143","article-title":"Higher satisfaction and function scores in restricted kinematic alignment versus mechanical alignment with medial pivot design total knee arthroplasty: a\u00a0prospective randomised controlled trial","volume":"32","author":"Ettinger M","year":"2024","unstructured":"Ettinger M, Tuecking LR, Savov P, Windhagen H. Higher satisfaction and function scores in restricted kinematic alignment versus mechanical alignment with medial pivot design total knee arthroplasty: a\u00a0prospective randomised controlled trial. Knee Surg Sports Traumatol Arthrosc. 2024, 32:1275-86. 10.1002\/ksa.12143","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1186\/s10195-023-00702-w","article-title":"Coronal alignment in total knee arthroplasty: a review","volume":"24","author":"Matassi F","year":"2023","unstructured":"Matassi F, Pettinari F, Frascon\u00e0 F, Innocenti M, Civinini R. Coronal alignment in total knee arthroplasty: a review. J Orthop Traumatol. 2023, 24:24. 10.1186\/s10195-023-00702-w","journal-title":"J Orthop Traumatol"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1007\/s11999-011-1936-5","article-title":"The Chitranjan Ranawat award: is neutral mechanical alignment normal for all patients? The concept of constitutional varus","volume":"470","author":"Bellemans J","year":"2012","unstructured":"Bellemans J, Colyn W, Vandenneucker H, Victor J. The Chitranjan Ranawat award: is neutral mechanical alignment normal for all patients? The concept of constitutional varus. Clin Orthop Relat Res. 2012, 470:45-53. 10.1007\/s11999-011-1936-5","journal-title":"Clin Orthop Relat Res"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.101B8.BJJ-2018-0755.R3","article-title":"A randomized controlled trial of tibial component migration with kinematic alignment using patient-specific instrumentation versus mechanical alignment using computer-assisted surgery in total knee arthroplasty","volume":"101-B","author":"Laende EK","year":"2019","unstructured":"Laende EK, Richardson CG, Dunbar MJ. A randomized controlled trial of tibial component migration with kinematic alignment using patient-specific instrumentation versus mechanical alignment using computer-assisted surgery in total knee arthroplasty. Bone Joint J. 2019, 101-B:929-40. 10.1302\/0301-620X.101B8.BJJ-2018-0755.R3","journal-title":"Bone Joint J"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.96B7.32812","article-title":"A randomised controlled trial of kinematically and mechanically aligned total knee replacements: two-year clinical results","volume":"96-B","author":"Dossett HG","year":"2014","unstructured":"Dossett HG, Estrada NA, Swartz GJ, LeFevre GW, Kwasman BG. A randomised controlled trial of kinematically and mechanically aligned total knee replacements: two-year clinical results. Bone Joint J. 2014, 96-B:907-13. 10.1302\/0301-620X.96B7.32812","journal-title":"Bone Joint J"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1007\/s00167-020-06165-4","article-title":"Higher satisfaction after total knee arthroplasty using restricted inverse kinematic alignment compared to adjusted mechanical alignment","volume":"30","author":"Winnock de Grave P","year":"2022","unstructured":"Winnock de Grave P, Luyckx T, Claeys K, Tampere T, Kellens J, M\u00fcller J, Gunst P. Higher satisfaction after total knee arthroplasty using restricted inverse kinematic alignment compared to adjusted mechanical alignment. Knee Surg Sports Traumatol Arthrosc. 2022, 30:488-99. 10.1007\/s00167-020-06165-4","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2019.08.064","article-title":"Computer-assisted kinematic and mechanical axis total knee arthroplasty: a prospective randomized controlled trial of bilateral simultaneous surgery","volume":"35","author":"McEwen PJ","year":"2020","unstructured":"McEwen PJ, Dlaska CE, Jovanovic IA, Doma K, Brandon BJ. Computer-assisted kinematic and mechanical axis total knee arthroplasty: a prospective randomized controlled trial of bilateral simultaneous surgery. J Arthroplasty. 2020, 35:443-50. 10.1016\/j.arth.2019.08.064","journal-title":"J Arthroplasty"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.n71","article-title":"The PRISMA 2020 statement: an updated guideline for reporting systematic reviews","volume":"372","author":"Page MJ","year":"2021","unstructured":"Page MJ, McKenzie JE, Bossuyt PM, et al.. The PRISMA 2020 statement: an updated guideline for reporting systematic reviews. BMJ. 2021, 372:n71. 10.1136\/bmj.n71","journal-title":"BMJ"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.1186\/1472-6947-7-16","article-title":"Utilization of the PICO framework to improve searching PubMed for clinical questions","volume":"7","author":"Schardt C","year":"2007","unstructured":"Schardt C, Adams MB, Owens T, Keitz S, Fontelo P. Utilization of the PICO framework to improve searching PubMed for clinical questions. BMC Med Inform Decis Mak. 2007, 7:16. 10.1186\/1472-6947-7-16","journal-title":"BMC Med Inform Decis Mak"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1136\/jech.52.6.377","article-title":"The feasibility of creating a checklist for the assessment of the methodological quality both of randomised and non-randomised studies of health care interventions","volume":"52","author":"Downs SH","year":"1998","unstructured":"Downs SH, Black N. The feasibility of creating a checklist for the assessment of the methodological quality both of randomised and non-randomised studies of health care interventions. J Epidemiol Community Health. 1998, 52:377-84. 10.1136\/jech.52.6.377","journal-title":"J Epidemiol Community Health"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.3928\/01477447-20120123-04","article-title":"Kinematically versus mechanically aligned total knee arthroplasty","volume":"35","author":"Dossett HG","year":"2012","unstructured":"Dossett HG, Swartz GJ, Estrada NA, LeFevre GW, Kwasman BG. Kinematically versus mechanically aligned total knee arthroplasty. Orthopedics. 2012, 35:e160-9. 10.3928\/01477447-20120123-04","journal-title":"Orthopedics"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.99B5.BJJ-2016-0688.R2","article-title":"Radiological and clinical comparison of kinematically versus mechanically aligned total knee arthroplasty","volume":"99-B","author":"Matsumoto T","year":"2017","unstructured":"Matsumoto T, Takayama K, Ishida K, Hayashi S, Hashimoto S, Kuroda R. Radiological and clinical comparison of kinematically versus mechanically aligned total knee arthroplasty. Bone Joint J. 2017, 99-B:640-6. 10.1302\/0301-620X.99B5.BJJ-2016-0688.R2","journal-title":"Bone Joint J"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.1007\/s00167-018-5133-x","article-title":"No difference in outcomes and gait analysis between mechanical and kinematic knee alignment methods using robotic total knee arthroplasty","volume":"27","author":"Yeo JH","year":"2019","unstructured":"Yeo JH, Seon JK, Lee DH, Song EK. No difference in outcomes and gait analysis between mechanical and kinematic knee alignment methods using robotic total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc. 2019, 27:1142-7. 10.1007\/s00167-018-5133-x","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"ref15","doi-asserted-by":"publisher","DOI":"10.1007\/s00167-016-4136-8","article-title":"PSI kinematic versus non-PSI mechanical alignment in total knee arthroplasty: a prospective, randomized study","volume":"25","author":"Calliess T","year":"2017","unstructured":"Calliess T, Bauer K, Stukenborg-Colsman C, Windhagen H, Budde S, Ettinger M. PSI kinematic versus non-PSI mechanical alignment in total knee arthroplasty: a prospective, randomized study. Knee Surg Sports Traumatol Arthrosc. 2017, 25:1743-8. 10.1007\/s00167-016-4136-8","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"ref16","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2023.03.065","article-title":"A randomized controlled trial of kinematically and mechanically aligned total knee arthroplasties: long-term follow-up","volume":"38","author":"Dossett HG","year":"2023","unstructured":"Dossett HG, Arthur JR, Makovicka JL, Mara KC, Bingham JS, Clarke HD, Spangehl MJ. A randomized controlled trial of kinematically and mechanically aligned total knee arthroplasties: long-term follow-up. J Arthroplasty. 2023, 38:S209-14. 10.1016\/j.arth.2023.03.065","journal-title":"J Arthroplasty"},{"key":"ref17","doi-asserted-by":"publisher","DOI":"10.1186\/s42836-025-00310-5","article-title":"Comparative effects of mechanical and functional alignment in bilateral robotic total knee arthroplasty: a randomized controlled trial","volume":"7","author":"Chompoosang T","year":"2025","unstructured":"Chompoosang T, Ketkaewsuwan U, Ploynumpon P. Comparative effects of mechanical and functional alignment in bilateral robotic total knee arthroplasty: a randomized controlled trial. Arthroplasty. 2025, 7:25. 10.1186\/s42836-025-00310-5","journal-title":"Arthroplasty"},{"key":"ref18","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.98B10.36862","article-title":"The early outcome of kinematic versus mechanical alignment in total knee arthroplasty: a prospective randomised control trial","volume":"98-B","author":"Waterson HB","year":"2016","unstructured":"Waterson HB, Clement ND, Eyres KS, Mandalia VI, Toms AD. The early outcome of kinematic versus mechanical alignment in total knee arthroplasty: a prospective randomised control trial. Bone Joint J. 2016, 98-B:1360-8. 10.1302\/0301-620X.98B10.36862","journal-title":"Bone Joint J"},{"key":"ref19","doi-asserted-by":"publisher","DOI":"10.1055\/s-0039-1688504","article-title":"Intraoperative soft tissue balance\/kinematics and clinical evaluation of modified kinematically versus mechanically aligned total knee arthroplasty","volume":"33","author":"Matsumoto T","year":"2020","unstructured":"Matsumoto T, Takayama K, Ishida K, et al.. Intraoperative soft tissue balance\/kinematics and clinical evaluation of modified kinematically versus mechanically aligned total knee arthroplasty. J Knee Surg. 2020, 33:777-84. 10.1055\/s-0039-1688504","journal-title":"J Knee Surg"}],"container-title":["Cureus"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cureus.com\/articles\/424876-functional-outcomes-and-patient-satisfaction-in-kinematic-vs-mechanical-alignment-total-knee-arthroplasty-a-systematic-review","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,6]],"date-time":"2025-10-06T16:37:37Z","timestamp":1759768657000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cureus.com\/articles\/424876-functional-outcomes-and-patient-satisfaction-in-kinematic-vs-mechanical-alignment-total-knee-arthroplasty-a-systematic-review"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,10,6]]},"references-count":19,"URL":"https:\/\/doi.org\/10.7759\/cureus.93939","relation":{},"ISSN":["2168-8184"],"issn-type":[{"value":"2168-8184","type":"print"}],"subject":[],"published":{"date-parts":[[2025,10,6]]}}}