{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,2,10]],"date-time":"2024-02-10T00:15:05Z","timestamp":1707524105985},"reference-count":14,"publisher":"Springer Science and Business Media LLC","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2020,8,13]]},"DOI":"10.7759\/cureus.9720","type":"journal-article","created":{"date-parts":[[2020,8,13]],"date-time":"2020-08-13T17:25:35Z","timestamp":1597339535000},"source":"Crossref","is-referenced-by-count":0,"title":["Using Video-Assisted Laryngoscope (GlideScope\u00ae) to Insert a Nasogastric Tube and Prevent Pneumothorax From Incorrectly Inserted Nasogastric Tubes"],"prefix":"10.7759","author":[{"given":"Oday Z","family":"AlHafidh","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Danilo","family":"Enriquez","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Joseph","family":"Quist","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Frances","family":"Schmidt","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","reference":[{"key":"ref1","doi-asserted-by":"crossref","DOI":"10.5339\/qmj.2016.12","article-title":"Down the wrong road - a case report of inadvertent nasogastric tube insertion leading to lung laceration and important pearls to avoid complications","volume":"2016","author":"Mohiuddin SA","year":"2016","unstructured":"Mohiuddin SA, Al Kaabi S, Butt T, Yakoob R, Khanna M. Down the wrong road - a case report of inadvertent nasogastric tube insertion leading to lung laceration and important pearls to avoid complications. Qatar Med J. 2016, 2016:12.","journal-title":"Qatar Med J"},{"key":"ref2","article-title":"Deaths associated with insertion of nasogastric tubes for enteral nutrition in the medical intensive care unit: clinical and autopsy findings","volume":"31","author":"Smith AL","year":"2018","unstructured":"Smith AL, Santa Ana CA, Fordtran JS, Guileyardo JM. Deaths associated with insertion of nasogastric tubes for enteral nutrition in the medical intensive care unit: clinical and autopsy findings. Proc (Bayl Univ Med Cent). 2018, 31:310-316.","journal-title":"Proc (Bayl Univ Med Cent)"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1155\/2016\/7532172","article-title":"Novel visual nasogastric tube insertion system: a feasibility and efficiency study in a manikin","volume":"2016","author":"Li Q","year":"2016","unstructured":"Li Q, Xie J, Wu J, et al.. Novel visual nasogastric tube insertion system: a feasibility and efficiency study in a manikin. Gastroenterol Res Pract. 2016, 2016:7532172. 10.1155\/2016\/7532172","journal-title":"Gastroenterol Res Pract"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1046\/j.1365-2044.1999.1133k.x","article-title":"Tension pneumothorax and pneumomediastinum after nasogastric tube insertion","volume":"54","author":"Kannan S","year":"1999","unstructured":"Kannan S, Morrow B, Furness G. Tension pneumothorax and pneumomediastinum after nasogastric tube insertion. Anesthesia. 1999, 54:1012-1013. 10.1046\/j.1365-2044.1999.1133k.x","journal-title":"Anesthesia"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1186\/cc120","article-title":"A prospective study of tracheopulmonary complications associated with the placement of narrow-bore enteral feeding tubes","volume":"2","author":"Rassias AJ","year":"1998","unstructured":"Rassias AJ, Ball PA, Corwin HL. A prospective study of tracheopulmonary complications associated with the placement of narrow-bore enteral feeding tubes. Crit Care. 1998, 2:25-28. 10.1186\/cc120","journal-title":"Crit Care"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1097\/00007611-197902000-00035","article-title":"Inadvertent intracranial placement of a nasogastric tube through a basal skull fracture","volume":"72","author":"Galloway DC","year":"1979","unstructured":"Galloway DC, Grudis J. Inadvertent intracranial placement of a nasogastric tube through a basal skull fracture. South Med J. 1979, 72:240-241. 10.1097\/00007611-197902000-00035","journal-title":"South Med J"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1016\/j.jamcollsurg.2004.03.011","article-title":"Patient safety: effect of institutional protocols on adverse events related to feeding tube placement in the critically ill","volume":"199","author":"Marderstein EL","year":"2004","unstructured":"Marderstein EL, Simmons RL, Ochoa JB. Patient safety: effect of institutional protocols on adverse events related to feeding tube placement in the critically ill. J Am Coll Surg. 2004, 199:39-50. 10.1016\/j.jamcollsurg.2004.03.011","journal-title":"J Am Coll Surg"},{"key":"ref8","unstructured":"Nasogastric tube errors. (2017). Accessed. July 27, 2020: https:\/\/www.medicalprotection.org\/uk\/articles\/nasogastric-tube-errors."},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.1177\/0148607190014001108","article-title":"Flexible nasogastric feeding tube tip malposition immediately after placement","volume":"14","author":"Benya R","year":"1990","unstructured":"Benya R, Langer S, Mobarhan S. Flexible nasogastric feeding tube tip malposition immediately after placement. JPEN J Parenter Enteral Nutr. 1990, 14:108-109. 10.1177\/0148607190014001108","journal-title":"JPEN J Parenter Enteral Nutr"},{"key":"ref10","doi-asserted-by":"crossref","DOI":"10.4103\/0972-5229.188214","article-title":"Nasogastric tube insertion easily done: the SORT maneuver","volume":"20","author":"Najafi M","year":"2016","unstructured":"Najafi M. Nasogastric tube insertion easily done: the SORT maneuver. Indian J Crit Care Med. 2016, 20:492-493.","journal-title":"Indian J Crit Care Med"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1097\/00003246-200210000-00013","article-title":"Use of capnometry to verify feeding tube placement","volume":"30","author":"Araujo-Preza CE","year":"2002","unstructured":"Araujo-Preza CE, Melhado ME, Gutierrez FJ, Maniatis T, Castellano MA. Use of capnometry to verify feeding tube placement. Crit Care Med. 2002, 30:2255-2259. 10.1097\/00003246-200210000-00013","journal-title":"Crit Care Med"},{"key":"ref12","doi-asserted-by":"crossref","DOI":"10.1001\/archinte.1989.00390010156022","article-title":"Pneumothorax due to nasogastric feeding tubes. Report of four cases, review of the literature, and recommendations for prevention","volume":"149","author":"Roubenoff R","year":"1989","unstructured":"Roubenoff R, Ravich WJ. Pneumothorax due to nasogastric feeding tubes. Report of four cases, review of the literature, and recommendations for prevention. Arch Intern Med. 1989, 149:184-188.","journal-title":"Arch Intern Med"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1016\/j.bjane.2014.11.013","article-title":"Comparing insertion characteristics on nasogastric tube placement by using GlideScope\u2122 visualization vs. MacIntosh laryngoscope assistance in anaesthetized and intubated patients","volume":"66","author":"Wan Ibadullah WH","year":"2016","unstructured":"Wan Ibadullah WH, Yahya N, Ghazali SS, Kamaruzaman E, Yong LC, Dan A, Zain JM. Comparing insertion characteristics on nasogastric tube placement by using GlideScope\u2122 visualization vs. MacIntosh laryngoscope assistance in anaesthetized and intubated patients. Braz J Anesthesiol. 2016, 66:363-368. 10.1016\/j.bjane.2014.11.013","journal-title":"Braz J Anesthesiol"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.1213\/ANE.0b013e3181be0e43","article-title":"The GlideScope\u00ae facilitates nasogastric tube insertion: a randomized clinical trial","volume":"110","author":"Moharari RS","year":"2010","unstructured":"Moharari RS, Fallah AH, Khajavi MR, Khashayar P, Lakeh MM, Najafi A. The GlideScope\u00ae facilitates nasogastric tube insertion: a randomized clinical trial. Anesth Analg. 2010, 110:115-118. 10.1213\/ANE.0b013e3181be0e43","journal-title":"Anesth Analg"}],"container-title":["Cureus"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cureus.com\/articles\/35911-using-video-assisted-laryngoscope-glidescope-to-insert-a-nasogastric-tube-and-prevent-pneumothorax-from-incorrectly-inserted-nasogastric-tubes","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,2,9]],"date-time":"2024-02-09T19:21:12Z","timestamp":1707506472000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cureus.com\/articles\/35911-using-video-assisted-laryngoscope-glidescope-to-insert-a-nasogastric-tube-and-prevent-pneumothorax-from-incorrectly-inserted-nasogastric-tubes"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,8,13]]},"references-count":14,"URL":"https:\/\/doi.org\/10.7759\/cureus.9720","relation":{},"ISSN":["2168-8184"],"issn-type":[{"value":"2168-8184","type":"print"}],"subject":[],"published":{"date-parts":[[2020,8,13]]}}}