{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,20]],"date-time":"2025-11-20T18:23:06Z","timestamp":1763662986432,"version":"3.45.0"},"reference-count":12,"publisher":"Springer Science and Business Media LLC","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2025,11,20]]},"DOI":"10.7759\/cureus.97350","type":"journal-article","created":{"date-parts":[[2025,11,20]],"date-time":"2025-11-20T18:10:45Z","timestamp":1763662245000},"source":"Crossref","is-referenced-by-count":0,"title":["Assessment of Retinal Function Using Full-Field Electroretinography in Patients Undergoing Vitrectomy for a Macular Hole"],"prefix":"10.7759","author":[{"given":"Aleksandra","family":"G\u00f3rska","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sebastian","family":"Sirek","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dorota","family":"Pojda-Wilczek","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1007\/s10633-022-09872-0","article-title":"ISCEV Standard for full-field clinical electroretinography (2022 update)","volume":"144","author":"Robson AG","year":"2022","unstructured":"Robson AG, Frishman LJ, Grigg J, et al.. ISCEV Standard for full-field clinical electroretinography (2022 update). Doc Ophthalmol. 2022, 144:165-77. 10.1007\/s10633-022-09872-0","journal-title":"Doc Ophthalmol"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1007\/s10633-018-9638-x","article-title":"ISCEV extended protocol for the photopic negative response (PhNR) of the full-field electroretinogram","volume":"136","author":"Frishman L","year":"2018","unstructured":"Frishman L, Sustar M, Kremers J, McAnany JJ, Sarossy M, Tzekov R, Viswanathan S. ISCEV extended protocol for the photopic negative response (PhNR) of the full-field electroretinogram. Doc Ophthalmol. 2018, 136:207-11. 10.1007\/s10633-018-9638-x","journal-title":"Doc Ophthalmol"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1007\/s10633-018-9645-y","article-title":"ISCEV extended protocol for the photopic On-Off ERG","volume":"136","author":"Sustar M","year":"2018","unstructured":"Sustar M, Holder GE, Kremers J, Barnes CS, Lei B, Khan NW, Robson AG. ISCEV extended protocol for the photopic On-Off ERG. Doc Ophthalmol. 2018, 136:199-206. 10.1007\/s10633-018-9645-y","journal-title":"Doc Ophthalmol"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-024-54099-5","article-title":"Electrophysiological findings in long-term type 1 diabetes patients without diabetic retinopathy using different ERG recording systems","volume":"14","author":"Arias-Alvarez M","year":"2024","unstructured":"Arias-Alvarez M, Tomas-Grasa C, Sope\u00f1a-Pinilla M, et al.. Electrophysiological findings in long-term type 1 diabetes patients without diabetic retinopathy using different ERG recording systems. Sci Rep. 2024, 14:3520. 10.1038\/s41598-024-54099-5","journal-title":"Sci Rep"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2010.02.011","article-title":"Inverted internal limiting membrane flap technique for large macular holes","volume":"117","author":"Michalewska Z","year":"2010","unstructured":"Michalewska Z, Michalewski J, Adelman RA, Nawrocki J. Inverted internal limiting membrane flap technique for large macular holes. Ophthalmology. 2010, 117:2018-25. 10.1016\/j.ophtha.2010.02.011","journal-title":"Ophthalmology"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1111\/opo.13460","article-title":"Measuring differences in the ERG in myopia using the RETeval device with skin electrodes","volume":"45","author":"Stapley V","year":"2025","unstructured":"Stapley V, Anderson RS, Saunders K, Mulholland PJ. Measuring differences in the ERG in myopia using the RETeval device with skin electrodes. Ophthalmic Physiol Opt. 2025, 45:666-80. 10.1111\/opo.13460","journal-title":"Ophthalmic Physiol Opt"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1007\/s10633-010-9239-9","article-title":"Inter-subject, inter-ocular and inter-session repeatability of the photopic negative response of the electroretinogram recorded using DTL and skin electrodes","volume":"121","author":"Mortlock KE","year":"2010","unstructured":"Mortlock KE, Binns AM, Aldebasi YH, North RV. Inter-subject, inter-ocular and inter-session repeatability of the photopic negative response of the electroretinogram recorded using DTL and skin electrodes. Doc Ophthalmol. 2010, 121:123-34. 10.1007\/s10633-010-9239-9","journal-title":"Doc Ophthalmol"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.3390\/cancers17091542","article-title":"The relationship between the ganglion cell-inner plexiform layer, retinal nerve fiber layer, and photopic negative response in newly diagnosed pituitary macroadenoma: 12-month prospective follow-up study","volume":"17","author":"Sarnat-Kucharczyk M","year":"2025","unstructured":"Sarnat-Kucharczyk M, Pojda-Wilczek D, Mrukwa-Kominek E, Kos-Kud\u0142a B, Janik MA, Janik P. The relationship between the ganglion cell-inner plexiform layer, retinal nerve fiber layer, and photopic negative response in newly diagnosed pituitary macroadenoma: 12-month prospective follow-up study. Cancers (Basel). 2025, 17:1542. 10.3390\/cancers17091542","journal-title":"Cancers (Basel)"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.05-1481","article-title":"Selective amplitude reduction of the PhNR after macular hole surgery: ganglion cell damage related to ICG-assisted ILM peeling and gas tamponade","volume":"47","author":"Ueno S","year":"2006","unstructured":"Ueno S, Kondo M, Piao CH, Ikenoya K, Miyake Y, Terasaki H. Selective amplitude reduction of the PhNR after macular hole surgery: ganglion cell damage related to ICG-assisted ILM peeling and gas tamponade. Invest Ophthalmol Vis Sci. 2006, 47:3545-9. 10.1167\/iovs.05-1481","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.1159\/000268031","article-title":"The M\u00fcller (glial) cell in normal and diseased retina: a case for single-cell electrophysiology","volume":"29","author":"Reichenbach A","year":"1997","unstructured":"Reichenbach A, Faude F, Enzmann V, et al.. The M\u00fcller (glial) cell in normal and diseased retina: a case for single-cell electrophysiology. Ophthalmic Res. 1997, 29:326-40. 10.1159\/000268031","journal-title":"Ophthalmic Res"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1007\/s00417-016-3478-8","article-title":"Comparisons of focal macular electroretinograms after indocyanine green-, brilliant blue G-, or triamcinolone acetonide-assisted macular hole surgery","volume":"255","author":"Machida S","year":"2017","unstructured":"Machida S, Nishimura T, Ohzeki T, Murai KI, Kurosaka D. Comparisons of focal macular electroretinograms after indocyanine green-, brilliant blue G-, or triamcinolone acetonide-assisted macular hole surgery. Graefes Arch Clin Exp Ophthalmol. 2017, 255:485-92. 10.1007\/s00417-016-3478-8","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1007\/s00417-014-2594-6","article-title":"Comparisons of cone electroretinograms after indocyanine green-, brilliant blue G-, or triamcinolone acetonide-assisted macular hole surgery","volume":"252","author":"Machida S","year":"2014","unstructured":"Machida S, Toba Y, Nishimura T, Ohzeki T, Murai K, Kurosaka D. Comparisons of cone electroretinograms after indocyanine green-, brilliant blue G-, or triamcinolone acetonide-assisted macular hole surgery. Graefes Arch Clin Exp Ophthalmol. 2014, 252:1423-33. 10.1007\/s00417-014-2594-6","journal-title":"Graefes Arch Clin Exp Ophthalmol"}],"container-title":["Cureus"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cureus.com\/articles\/429067-assessment-of-retinal-function-using-full-field-electroretinography-in-patients-undergoing-vitrectomy-for-a-macular-hole","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,11,20]],"date-time":"2025-11-20T18:10:45Z","timestamp":1763662245000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cureus.com\/articles\/429067-assessment-of-retinal-function-using-full-field-electroretinography-in-patients-undergoing-vitrectomy-for-a-macular-hole"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,11,20]]},"references-count":12,"URL":"https:\/\/doi.org\/10.7759\/cureus.97350","relation":{},"ISSN":["2168-8184"],"issn-type":[{"value":"2168-8184","type":"print"}],"subject":[],"published":{"date-parts":[[2025,11,20]]}}}