{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,8]],"date-time":"2025-12-08T22:27:42Z","timestamp":1765232862114,"version":"3.46.0"},"reference-count":42,"publisher":"Springer Science and Business Media LLC","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2025,12,8]]},"DOI":"10.7759\/cureus.98744","type":"journal-article","created":{"date-parts":[[2025,12,8]],"date-time":"2025-12-08T21:31:19Z","timestamp":1765229479000},"source":"Crossref","is-referenced-by-count":0,"title":["A Multimodal Non-invasive Approach for Intracranial Pressure Assessment: A Single-Center Study"],"prefix":"10.7759","author":[{"given":"Dana","family":"Klavansky","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Helaina","family":"Lehrer","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Aris","family":"Desai","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gabriela","family":"Keeton","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Neha","family":"Dangayach","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alexandra","family":"Reynolds","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Spyridoula","family":"Tsetsou","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1186\/s13054-020-03105-z","article-title":"Multimodal non-invasive assessment of intracranial hypertension: an observational study","volume":"24","author":"Robba C","year":"2020","unstructured":"Robba C, Pozzebon S, Moro B, Vincent JL, Creteur J, Taccone FS. Multimodal non-invasive assessment of intracranial hypertension: an observational study. Crit Care. 2020, 24:379. 10.1186\/s13054-020-03105-z","journal-title":"Crit Care"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1227\/NEU.0000000000001432","article-title":"Guidelines for the management of severe traumatic brain injury, fourth edition","volume":"80","author":"Carney N","year":"2017","unstructured":"Carney N, Totten AM, O'Reilly C, et al.. Guidelines for the management of severe traumatic brain injury, fourth edition. Neurosurgery. 2017, 80:6-15. 10.1227\/NEU.0000000000001432","journal-title":"Neurosurgery"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1007\/s12028-014-0041-5","article-title":"Consensus summary statement of the International Multidisciplinary Consensus Conference on Multimodality Monitoring in Neurocritical Care: a statement for healthcare professionals from the Neurocritical Care Society and the European Society of Intensive Care Medicine","volume":"21 Suppl 2","author":"Le Roux P","year":"2014","unstructured":"Le Roux P, Menon DK, Citerio G, et al.. Consensus summary statement of the International Multidisciplinary Consensus Conference on Multimodality Monitoring in Neurocritical Care: a statement for healthcare professionals from the Neurocritical Care Society and the European Society of Intensive Care Medicine. Neurocrit Care. 2014, 21 Suppl 2:S1-26. 10.1007\/s12028-014-0041-5","journal-title":"Neurocrit Care"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1007\/s00134-024-07756-2","article-title":"The Brussels consensus for non-invasive ICP monitoring when invasive systems are not available in the care of TBI patients (the B-ICONIC consensus, recommendations, and management algorithm)","volume":"51","author":"Robba C","year":"2025","unstructured":"Robba C, Picetti E, V\u00e1squez-Garc\u00eda S, et al.. The Brussels consensus for non-invasive ICP monitoring when invasive systems are not available in the care of TBI patients (the B-ICONIC consensus, recommendations, and management algorithm). Intensive Care Med. 2025, 51:4-20. 10.1007\/s00134-024-07756-2","journal-title":"Intensive Care Med"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1089\/neu.2007.9989","article-title":"Guidelines for the management of severe traumatic brain injury. VII. Intracranial pressure monitoring technology","volume":"24","author":"Bratton SL","year":"2007","unstructured":"Bratton SL, Chestnut RM, Ghajar J, et al.. Guidelines for the management of severe traumatic brain injury. VII. Intracranial pressure monitoring technology. J Neurotrauma. 2007, 24:S45-54. 10.1089\/neu.2007.9989","journal-title":"J Neurotrauma"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1590\/0004-282X-ANP-2020-0300","article-title":"Noninvasive intracranial pressure monitoring methods: a critical review","volume":"79","author":"Moraes FM","year":"2021","unstructured":"Moraes FM, Silva GS. Noninvasive intracranial pressure monitoring methods: a critical review. Arq Neuropsiquiatr. 2021, 79:437-46. 10.1590\/0004-282X-ANP-2020-0300","journal-title":"Arq Neuropsiquiatr"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pmed.1002356","article-title":"Ultrasound non-invasive measurement of intracranial pressure in neurointensive care: a prospective observational study","volume":"14","author":"Robba C","year":"2017","unstructured":"Robba C, Cardim D, Tajsic T, et al.. Ultrasound non-invasive measurement of intracranial pressure in neurointensive care: a prospective observational study. PLoS Med. 2017, 14:e1002356. 10.1371\/journal.pmed.1002356","journal-title":"PLoS Med"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1111\/ane.12527","article-title":"Non-invasive assessment of intracranial pressure","volume":"134","author":"Robba C","year":"2016","unstructured":"Robba C, Bacigaluppi S, Cardim D, Donnelly J, Bertuccio A, Czosnyka M. Non-invasive assessment of intracranial pressure. Acta Neurol Scand. 2016, 134:4-21. 10.1111\/ane.12527","journal-title":"Acta Neurol Scand"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.12998\/wjcc.v7.i13.1535","article-title":"Intracranial pressure monitoring: gold standard and recent innovations","volume":"7","author":"Nag DS","year":"2019","unstructured":"Nag DS, Sahu S, Swain A, Kant S. Intracranial pressure monitoring: gold standard and recent innovations. World J Clin Cases. 2019, 7:1535-53. 10.12998\/wjcc.v7.i13.1535","journal-title":"World J Clin Cases"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.1111\/jon.12100","article-title":"Usefulness of transcranial Doppler-derived cerebral hemodynamic parameters in the noninvasive assessment of intracranial pressure","volume":"25","author":"Wakerley BR","year":"2015","unstructured":"Wakerley BR, Kusuma Y, Yeo LL, Liang S, Kumar K, Sharma AK, Sharma VK. Usefulness of transcranial Doppler-derived cerebral hemodynamic parameters in the noninvasive assessment of intracranial pressure. J Neuroimaging. 2015, 25:111-6. 10.1111\/jon.12100","journal-title":"J Neuroimaging"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1002\/jcu.22279","article-title":"Noninvasive measurement of intracranial pressure via the pulsatility index on transcranial Doppler sonography: Is improvement possible?","volume":"44","author":"Morgalla MH","year":"2016","unstructured":"Morgalla MH, Magunia H. Noninvasive measurement of intracranial pressure via the pulsatility index on transcranial Doppler sonography: Is improvement possible?. J Clin Ultrasound. 2016, 44:40-5. 10.1002\/jcu.22279","journal-title":"J Clin Ultrasound"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1007\/BF01727619","article-title":"Intracranial flow patterns at increasing intracranial pressure","volume":"65","author":"Klingelh\u00f6fer J","year":"1987","unstructured":"Klingelh\u00f6fer J, Conrad B, Benecke R, Sander D. Intracranial flow patterns at increasing intracranial pressure. Klin Wochenschr. 1987, 65:542-5. 10.1007\/BF01727619","journal-title":"Klin Wochenschr"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1007\/BF00314307","article-title":"Evaluation of intracranial pressure from transcranial Doppler studies in cerebral disease","volume":"235","author":"Klingelh\u00f6fer J","year":"1988","unstructured":"Klingelh\u00f6fer J, Conrad B, Benecke R, Sander D, Markakis E. Evaluation of intracranial pressure from transcranial Doppler studies in cerebral disease. J Neurol. 1988, 235:159-62. 10.1007\/BF00314307","journal-title":"J Neurol"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.1186\/2193-1801-3-548","article-title":"Infrared pupillometry, the Neurological Pupil index and unilateral pupillary dilation after traumatic brain injury: implications for treatment paradigms","volume":"3","author":"Chen JW","year":"2014","unstructured":"Chen JW, Vakil-Gilani K, Williamson KL, Cecil S. Infrared pupillometry, the Neurological Pupil index and unilateral pupillary dilation after traumatic brain injury: implications for treatment paradigms. Springerplus. 2014, 3:548. 10.1186\/2193-1801-3-548","journal-title":"Springerplus"},{"key":"ref15","doi-asserted-by":"publisher","DOI":"10.4103\/2152-7806.82248","article-title":"Pupillary reactivity as an early indicator of increased intracranial pressure: the introduction of the Neurological Pupil index","volume":"2","author":"Chen JW","year":"2011","unstructured":"Chen JW, Gombart ZJ, Rogers S, Gardiner SK, Cecil S, Bullock RM. Pupillary reactivity as an early indicator of increased intracranial pressure: the introduction of the Neurological Pupil index. Surg Neurol Int. 2011, 2:82. 10.4103\/2152-7806.82248","journal-title":"Surg Neurol Int"},{"key":"ref16","doi-asserted-by":"publisher","DOI":"10.1111\/j.1553-2712.2007.00031.x","article-title":"Correlation of optic nerve sheath diameter with direct measurement of intracranial pressure","volume":"15","author":"Kimberly HH","year":"2008","unstructured":"Kimberly HH, Shah S, Marill K, Noble V. Correlation of optic nerve sheath diameter with direct measurement of intracranial pressure. Acad Emerg Med. 2008, 15:201-4. 10.1111\/j.1553-2712.2007.00031.x","journal-title":"Acad Emerg Med"},{"key":"ref17","doi-asserted-by":"publisher","DOI":"10.1007\/s00134-011-2224-2","article-title":"Ultrasonography of optic nerve sheath diameter for detection of raised intracranial pressure: a systematic review and meta-analysis","volume":"37","author":"Dubourg J","year":"2011","unstructured":"Dubourg J, Javouhey E, Geeraerts T, Messerer M, Kassai B. Ultrasonography of optic nerve sheath diameter for detection of raised intracranial pressure: a systematic review and meta-analysis. Intensive Care Med. 2011, 37:1059-68. 10.1007\/s00134-011-2224-2","journal-title":"Intensive Care Med"},{"key":"ref18","doi-asserted-by":"publisher","DOI":"10.1097\/PEC.0000000000000408","article-title":"Identification of optic disc elevation and the crescent sign using point-of-care ocular ultrasound in children","volume":"31","author":"Marchese RF","year":"2015","unstructured":"Marchese RF, Mistry RD, Scarfone RJ, Chen AE. Identification of optic disc elevation and the crescent sign using point-of-care ocular ultrasound in children. Pediatr Emerg Care. 2015, 31:304-7. 10.1097\/PEC.0000000000000408","journal-title":"Pediatr Emerg Care"},{"key":"ref19","doi-asserted-by":"publisher","DOI":"10.1111\/acem.12206","article-title":"Point-of-care ocular ultrasound to detect optic disc swelling","volume":"20","author":"Teismann N","year":"2013","unstructured":"Teismann N, Lenaghan P, Nolan R, Stein J, Green A. Point-of-care ocular ultrasound to detect optic disc swelling. Acad Emerg Med. 2013, 20:920-5. 10.1111\/acem.12206","journal-title":"Acad Emerg Med"},{"key":"ref20","doi-asserted-by":"publisher","DOI":"10.1155\/2013\/629378","article-title":"Transcranial Doppler ultrasound: a review of the physical principles and major applications in critical care","volume":"2013","author":"Naqvi J","year":"2013","unstructured":"Naqvi J, Yap KH, Ahmad G, Ghosh J. Transcranial Doppler ultrasound: a review of the physical principles and major applications in critical care. Int J Vasc Med. 2013, 2013:629378. 10.1155\/2013\/629378","journal-title":"Int J Vasc Med"},{"key":"ref21","doi-asserted-by":"publisher","DOI":"10.1016\/j.ncl.2008.02.003","article-title":"Management of intracranial hypertension","volume":"26","author":"Rangel-Castilla L","year":"2008","unstructured":"Rangel-Castilla L, Gopinath S, Robertson CS. Management of intracranial hypertension. Neurol Clin. 2008, 26:521-41. 10.1016\/j.ncl.2008.02.003","journal-title":"Neurol Clin"},{"key":"ref22","doi-asserted-by":"publisher","DOI":"10.1136\/jnnp.2003.033126","article-title":"Monitoring and interpretation of intracranial pressure","volume":"75","author":"Czosnyka M","year":"2004","unstructured":"Czosnyka M, Pickard JD. Monitoring and interpretation of intracranial pressure. J Neurol Neurosurg Psychiatry. 2004, 75:813-21. 10.1136\/jnnp.2003.033126","journal-title":"J Neurol Neurosurg Psychiatry"},{"key":"ref23","doi-asserted-by":"publisher","DOI":"10.1097\/CCM.0000000000003742","article-title":"Comparison of two techniques to measure optic nerve sheath diameter in patients at risk for increased intracranial pressure","volume":"47","author":"Agrawal A","year":"2019","unstructured":"Agrawal A, Cheng R, Tang J, Madhok DY. Comparison of two techniques to measure optic nerve sheath diameter in patients at risk for increased intracranial pressure. Crit Care Med. 2019, 47:e495-501. 10.1097\/CCM.0000000000003742","journal-title":"Crit Care Med"},{"key":"ref24","doi-asserted-by":"publisher","DOI":"10.5811\/cpcem.2018.1.36369","article-title":"Papilledema: point-of-care ultrasound diagnosis in the emergency department","volume":"2","author":"Sinnott JR","year":"2018","unstructured":"Sinnott JR, Mohebbi MR, Koboldt T. Papilledema: point-of-care ultrasound diagnosis in the emergency department. Clin Pract Cases Emerg Med. 2018, 2:125-7. 10.5811\/cpcem.2018.1.36369","journal-title":"Clin Pract Cases Emerg Med"},{"key":"ref25","doi-asserted-by":"publisher","DOI":"10.1177\/00359157740676P113","article-title":"Arterial assessment by Doppler-shift ultrasound","volume":"67","author":"Gosling RG","year":"1974","unstructured":"Gosling RG, King DH. Arterial assessment by Doppler-shift ultrasound. Proc R Soc Med. 1974, 67:447-9. 10.1177\/00359157740676P113","journal-title":"Proc R Soc Med"},{"key":"ref26","doi-asserted-by":"publisher","DOI":"10.4103\/sni.sni_403_16","article-title":"Noninvasive monitoring intracranial pressure - a review of available modalities","volume":"8","author":"Khan MN","year":"2017","unstructured":"Khan MN, Shallwani H, Khan MU, Shamim MS. Noninvasive monitoring intracranial pressure - a review of available modalities. Surg Neurol Int. 2017, 8:51. 10.4103\/sni.sni_403_16","journal-title":"Surg Neurol Int"},{"key":"ref27","doi-asserted-by":"publisher","DOI":"10.1093\/qjmed\/hcn036","article-title":"Emergency department evaluation of sudden, severe headache","volume":"101","author":"Breen DP","year":"2008","unstructured":"Breen DP, Duncan CW, Pope AE, Gray AJ, Al-Shahi Salman R. Emergency department evaluation of sudden, severe headache. QJM. 2008, 101:435-43. 10.1093\/qjmed\/hcn036","journal-title":"QJM"},{"key":"ref28","doi-asserted-by":"publisher","DOI":"10.1007\/s00134-018-5305-7","article-title":"Optic nerve sheath diameter measured sonographically as non-invasive estimator of intracranial pressure: a systematic review and meta-analysis","volume":"44","author":"Robba C","year":"2018","unstructured":"Robba C, Santori G, Czosnyka M, et al.. Optic nerve sheath diameter measured sonographically as non-invasive estimator of intracranial pressure: a systematic review and meta-analysis. Intensive Care Med. 2018, 44:1284-94. 10.1007\/s00134-018-5305-7","journal-title":"Intensive Care Med"},{"key":"ref29","doi-asserted-by":"publisher","DOI":"10.1055\/s-0043-1764411","article-title":"The use of noninvasive measurements of intracranial pressure in patients with traumatic brain injury: a narrative review","volume":"81","author":"Faria BC","year":"2023","unstructured":"Faria BC, Sacramento LG, Queiroz AV, Leite FA, Oliveira HL, Kimura TY, Faleiro RM. The use of noninvasive measurements of intracranial pressure in patients with traumatic brain injury: a narrative review. Arq Neuropsiquiatr. 2023, 81:551-63. 10.1055\/s-0043-1764411","journal-title":"Arq Neuropsiquiatr"},{"key":"ref30","doi-asserted-by":"publisher","DOI":"10.1007\/s12028-011-9606-8","article-title":"Optic nerve ultrasound for the detection of raised intracranial pressure","volume":"15","author":"Rajajee V","year":"2011","unstructured":"Rajajee V, Vanaman M, Fletcher JJ, Jacobs TL. Optic nerve ultrasound for the detection of raised intracranial pressure. Neurocrit Care. 2011, 15:506-15. 10.1007\/s12028-011-9606-8","journal-title":"Neurocrit Care"},{"key":"ref31","doi-asserted-by":"publisher","DOI":"10.1016\/j.jss.2011.03.009","article-title":"Sonographic optic nerve sheath diameter as an estimate of intracranial pressure in adult trauma","volume":"170","author":"Strumwasser A","year":"2011","unstructured":"Strumwasser A, Kwan RO, Yeung L, et al.. Sonographic optic nerve sheath diameter as an estimate of intracranial pressure in adult trauma. J Surg Res. 2011, 170:265-71. 10.1016\/j.jss.2011.03.009","journal-title":"J Surg Res"},{"key":"ref32","doi-asserted-by":"publisher","DOI":"10.1002\/jnr.24148","article-title":"Transcranial Doppler: a stethoscope for the brain-neurocritical care use","volume":"96","author":"Robba C","year":"2018","unstructured":"Robba C, Cardim D, Sekhon M, Budohoski K, Czosnyka M. Transcranial Doppler: a stethoscope for the brain-neurocritical care use. J Neurosci Res. 2018, 96:720-30. 10.1002\/jnr.24148","journal-title":"J Neurosci Res"},{"key":"ref33","doi-asserted-by":"publisher","DOI":"10.1007\/s12028-024-01951-1","article-title":"Noninvasive intracranial pressure monitoring: are we there yet?","volume":"41","author":"Rajajee V","year":"2024","unstructured":"Rajajee V. Noninvasive intracranial pressure monitoring: are we there yet?. Neurocrit Care. 2024, 41:332-8. 10.1007\/s12028-024-01951-1","journal-title":"Neurocrit Care"},{"key":"ref34","doi-asserted-by":"publisher","DOI":"10.1007\/s12028-016-0258-6","article-title":"Non-invasive monitoring of intracranial pressure using transcranial doppler ultrasonography: is it possible?","volume":"25","author":"Cardim D","year":"2016","unstructured":"Cardim D, Robba C, Bohdanowicz M, et al.. Non-invasive monitoring of intracranial pressure using transcranial doppler ultrasonography: is it possible?. Neurocrit Care. 2016, 25:473-91. 10.1007\/s12028-016-0258-6","journal-title":"Neurocrit Care"},{"key":"ref35","article-title":"Transcranial Doppler pulsatility index: not an accurate method to assess intracranial pressure","volume":"66","author":"Behrens A","unstructured":"Behrens A, Lenfeldt N, Ambarki K, et al.. Transcranial Doppler pulsatility index: not an accurate method to assess intracranial pressure. Neurosurgery. 66:1050-7.","journal-title":"Neurosurgery"},{"key":"ref36","doi-asserted-by":"publisher","DOI":"10.1007\/s12028-012-9672-6","article-title":"Transcranial Doppler pulsatility index: what it is and what it isn't","volume":"17","author":"de Riva N","year":"2012","unstructured":"de Riva N, Budohoski KP, Smielewski P, et al.. Transcranial Doppler pulsatility index: what it is and what it isn't. Neurocrit Care. 2012, 17:58-66. 10.1007\/s12028-012-9672-6","journal-title":"Neurocrit Care"},{"key":"ref37","doi-asserted-by":"publisher","DOI":"10.1186\/s13054-022-03978-2","article-title":"Transcranial Doppler as a screening test to exclude intracranial hypertension in brain-injured patients: the IMPRESSIT-2 prospective multicenter international study","volume":"26","author":"Rasulo FA","year":"2022","unstructured":"Rasulo FA, Calza S, Robba C, et al.. Transcranial Doppler as a screening test to exclude intracranial hypertension in brain-injured patients: the IMPRESSIT-2 prospective multicenter international study. Crit Care. 2022, 26:110. 10.1186\/s13054-022-03978-2","journal-title":"Crit Care"},{"key":"ref38","doi-asserted-by":"publisher","DOI":"10.4103\/2277-9175.151574","article-title":"The value of transcranial Doppler derived pulsatility index for diagnosing cerebral small-vessel disease","volume":"4","author":"Ghorbani A","year":"2015","unstructured":"Ghorbani A, Ahmadi MJ, Shemshaki H. The value of transcranial Doppler derived pulsatility index for diagnosing cerebral small-vessel disease. Adv Biomed Res. 2015, 4:54. 10.4103\/2277-9175.151574","journal-title":"Adv Biomed Res"},{"key":"ref39","doi-asserted-by":"publisher","DOI":"10.3171\/jns.2003.98.1.0205","article-title":"Quantitative pupillometry, a new technology: normative data and preliminary observations in patients with acute head injury. Technical note","volume":"98","author":"Taylor WR","year":"2003","unstructured":"Taylor WR, Chen JW, Meltzer H, et al.. Quantitative pupillometry, a new technology: normative data and preliminary observations in patients with acute head injury. Technical note. J Neurosurg. 2003, 98:205-13. 10.3171\/jns.2003.98.1.0205","journal-title":"J Neurosurg"},{"key":"ref40","doi-asserted-by":"publisher","DOI":"10.3171\/jns.1983.58.4.0566","article-title":"The oval pupil: clinical significance and relationship to intracranial hypertension","volume":"58","author":"Marshall LF","year":"1983","unstructured":"Marshall LF, Barba D, Toole BM, Bowers SA. The oval pupil: clinical significance and relationship to intracranial hypertension. J Neurosurg. 1983, 58:566-8. 10.3171\/jns.1983.58.4.0566","journal-title":"J Neurosurg"},{"key":"ref41","doi-asserted-by":"publisher","DOI":"10.1016\/j.wneu.2017.07.022","article-title":"Prospective evaluation of noninvasive HeadSense intracranial pressure monitor in traumatic brain injury patients undergoing invasive intracranial pressure monitoring","volume":"106","author":"Herklots MW","year":"2017","unstructured":"Herklots MW, Moudrous W, Oldenbeuving A, Roks G, Mourtzoukos S, Schoonman GG, Ganslandt O. Prospective evaluation of noninvasive HeadSense intracranial pressure monitor in traumatic brain injury patients undergoing invasive intracranial pressure monitoring. World Neurosurg. 2017, 106:557-62. 10.1016\/j.wneu.2017.07.022","journal-title":"World Neurosurg"},{"key":"ref42","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0204939","article-title":"Noninvasive intracranial pressure assessment using otoacoustic emissions: an application in glaucoma","volume":"13","author":"Loiselle AR","year":"2018","unstructured":"Loiselle AR, de Kleine E, van Dijk P, Jansonius NM. Noninvasive intracranial pressure assessment using otoacoustic emissions: an application in glaucoma. PLoS One. 2018, 13:e0204939. 10.1371\/journal.pone.0204939","journal-title":"PLoS One"}],"container-title":["Cureus"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cureus.com\/articles\/410546-a-multimodal-non-invasive-approach-for-intracranial-pressure-assessment-a-single-center-study","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,12,8]],"date-time":"2025-12-08T21:31:20Z","timestamp":1765229480000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cureus.com\/articles\/410546-a-multimodal-non-invasive-approach-for-intracranial-pressure-assessment-a-single-center-study"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,12,8]]},"references-count":42,"URL":"https:\/\/doi.org\/10.7759\/cureus.98744","relation":{},"ISSN":["2168-8184"],"issn-type":[{"value":"2168-8184","type":"print"}],"subject":[],"published":{"date-parts":[[2025,12,8]]}}}