{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,11]],"date-time":"2025-12-11T11:50:44Z","timestamp":1765453844359,"version":"3.46.0"},"reference-count":16,"publisher":"Springer Science and Business Media LLC","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2025,12,11]]},"DOI":"10.7759\/cureus.98955","type":"journal-article","created":{"date-parts":[[2025,12,11]],"date-time":"2025-12-11T11:13:43Z","timestamp":1765451623000},"source":"Crossref","is-referenced-by-count":0,"title":["Successful Repair of Glaucoma Drainage Device Tube Exposure With a Corneal Patch Graft and Double-Layer Amniotic Membrane: A Case Report"],"prefix":"10.7759","author":[{"given":"Shew-Fei","family":"Chee","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kar-Yong","family":"Chong","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kamaruddin","family":"Haireen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Embong","family":"Zunaina","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kwang-Sheng","family":"Ng","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2008.03.031","article-title":"Aqueous shunts in glaucoma: a report by the American Academy of Ophthalmology","volume":"115","author":"Minckler DS","year":"2008","unstructured":"Minckler DS, Francis BA, Hodapp EA, et al.. Aqueous shunts in glaucoma: a report by the American Academy of Ophthalmology. Ophthalmology. 2008, 115:1089-98. 10.1016\/j.ophtha.2008.03.031","journal-title":"Ophthalmology"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2015.05.025","article-title":"Glaucoma drainage devices: risk of exposure and infection","volume":"160","author":"Levinson JD","year":"2015","unstructured":"Levinson JD, Giangiacomo AL, Beck AD, Pruett PB, Superak HM, Lynn MJ, Costarides AP. Glaucoma drainage devices: risk of exposure and infection. Am J Ophthalmol. 2015, 160:516-521.e2. 10.1016\/j.ajo.2015.05.025","journal-title":"Am J Ophthalmol"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1097\/IJG.0000000000001220","article-title":"Risk factors for glaucoma drainage device exposure in a Middle-Eastern population","volume":"28","author":"Al-Beishri AS","year":"2019","unstructured":"Al-Beishri AS, Malik R, Freidi A, Ahmad S. Risk factors for glaucoma drainage device exposure in a Middle-Eastern population. J Glaucoma. 2019, 28:529-34. 10.1097\/IJG.0000000000001220","journal-title":"J Glaucoma"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.2147\/OPTH.S104029","article-title":"Risk factors for tube exposure as a late complication of glaucoma drainage implant surgery","volume":"10","author":"Chaku M","year":"2016","unstructured":"Chaku M, Netland PA, Ishida K, Rhee DJ. Risk factors for tube exposure as a late complication of glaucoma drainage implant surgery. Clin Ophthalmol. 2016, 10:547-53. 10.2147\/OPTH.S104029","journal-title":"Clin Ophthalmol"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0b013e3181814d15","article-title":"Corneal patch graft repair of exposed glaucoma drainage implants","volume":"27","author":"Singh M","year":"2008","unstructured":"Singh M, Chew PT, Tan D. Corneal patch graft repair of exposed glaucoma drainage implants. Cornea. 2008, 27:1171-3. 10.1097\/ICO.0b013e3181814d15","journal-title":"Cornea"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.2005.084905","article-title":"A novel use of amniotic membrane in the management of tube exposure following glaucoma tube shunt surgery","volume":"90","author":"Ainsworth G","year":"2006","unstructured":"Ainsworth G, Rotchford A, Dua HS, King AJ. A novel use of amniotic membrane in the management of tube exposure following glaucoma tube shunt surgery. Br J Ophthalmol. 2006, 90:417-9. 10.1136\/bjo.2005.084905","journal-title":"Br J Ophthalmol"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0137913","article-title":"The cost-effectiveness analysis of teleglaucoma screening device","volume":"10","author":"Thomas S","year":"2015","unstructured":"Thomas S, Hodge W, Malvankar-Mehta M. The cost-effectiveness analysis of teleglaucoma screening device. PLoS One. 2015, 10:e0137913. 10.1371\/journal.pone.0137913","journal-title":"PLoS One"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1097\/ICU.0b013e32834ff2d1","article-title":"The Tube Versus Trabeculectomy Study: interpretation of results and application to clinical practice","volume":"23","author":"Gedde SJ","year":"2012","unstructured":"Gedde SJ, Singh K, Schiffman JC, Feuer WJ. The Tube Versus Trabeculectomy Study: interpretation of results and application to clinical practice. Curr Opin Ophthalmol. 2012, 23:118-26. 10.1097\/ICU.0b013e32834ff2d1","journal-title":"Curr Opin Ophthalmol"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2015.11.023","article-title":"Postoperative complications in the Ahmed Baerveldt Comparison Study during five years of follow-up","volume":"163","author":"Budenz DL","year":"2016","unstructured":"Budenz DL, Feuer WJ, Barton K, Schiffman J, Costa VP, Godfrey DG, Buys YM. Postoperative complications in the Ahmed Baerveldt Comparison Study during five years of follow-up. Am J Ophthalmol. 2016, 163:75-82.e3. 10.1016\/j.ajo.2015.11.023","journal-title":"Am J Ophthalmol"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2008.09.003","article-title":"Superior versus inferior Ahmed glaucoma valve implantation","volume":"116","author":"Pakravan M","year":"2009","unstructured":"Pakravan M, Yazdani S, Shahabi C, Yaseri M. Superior versus inferior Ahmed glaucoma valve implantation. Ophthalmology. 2009, 116:208-13. 10.1016\/j.ophtha.2008.09.003","journal-title":"Ophthalmology"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1097\/IJG.0000000000000951","article-title":"Repair of exposed Ahmed glaucoma valve tubes: long-term outcomes","volume":"27","author":"Einan-Lifshitz A","year":"2018","unstructured":"Einan-Lifshitz A, Belkin A, Mathew D, et al.. Repair of exposed Ahmed glaucoma valve tubes: long-term outcomes. J Glaucoma. 2018, 27:532-6. 10.1097\/IJG.0000000000000951","journal-title":"J Glaucoma"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1001\/jamaophthalmol.2013.2315","article-title":"Forniceal conjunctival pedicle flap for the treatment of complex glaucoma drainage device tube erosion","volume":"131","author":"Grover DS","year":"2013","unstructured":"Grover DS, Merritt J, Godfrey DG, Fellman RL. Forniceal conjunctival pedicle flap for the treatment of complex glaucoma drainage device tube erosion. JAMA Ophthalmol. 2013, 131:662-6. 10.1001\/jamaophthalmol.2013.2315","journal-title":"JAMA Ophthalmol"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1097\/IJG.0000000000000014","article-title":"Corneal patch graft for the repair of late-onset hypotony or filtering bleb leak after trabeculectomy: a new surgical technique","volume":"23","author":"Bochmann F","year":"2014","unstructured":"Bochmann F, Kaufmann C, Kipfer A, Thiel MA. Corneal patch graft for the repair of late-onset hypotony or filtering bleb leak after trabeculectomy: a new surgical technique. J Glaucoma. 2014, 23:e76-80. 10.1097\/IJG.0000000000000014","journal-title":"J Glaucoma"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.3928\/15428877-20110426-01","article-title":"Use of amniotic membrane graft in glaucoma shunt surgery","volume":"42","author":"Anand A","year":"2011","unstructured":"Anand A, Sheha H, Teng CC, Liebmann JM, Ritch R, Tello C. Use of amniotic membrane graft in glaucoma shunt surgery. Ophthalmic Surg Lasers Imaging. 2011, 42:184-9. 10.3928\/15428877-20110426-01","journal-title":"Ophthalmic Surg Lasers Imaging"},{"key":"ref15","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.2003.025528","article-title":"A protocol for low contamination risk of autologous serum drops in the management of ocular surface disorders","volume":"88","author":"Lagnado R","year":"2004","unstructured":"Lagnado R, King AJ, Donald F, Dua HS. A protocol for low contamination risk of autologous serum drops in the management of ocular surface disorders. Br J Ophthalmol. 2004, 88:464-5. 10.1136\/bjo.2003.025528","journal-title":"Br J Ophthalmol"},{"key":"ref16","article-title":"Scleral patch with amniotic membrane for tube exposure of glaucoma drainage device in a Malaysian tertiary eye centre","volume":"7","author":"Koay JB","year":"2025","unstructured":"Koay JB, Shakira J, Farrah J, Jemaima CH. Scleral patch with amniotic membrane for tube exposure of glaucoma drainage device in a Malaysian tertiary eye centre.  Malaysia J Ophthalmol. 2025, 7:1-8.","journal-title":"Malaysia J Ophthalmol"}],"container-title":["Cureus"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cureus.com\/articles\/445463-successful-repair-of-glaucoma-drainage-device-tube-exposure-with-a-corneal-patch-graft-and-double-layer-amniotic-membrane-a-case-report","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,12,11]],"date-time":"2025-12-11T11:13:44Z","timestamp":1765451624000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cureus.com\/articles\/445463-successful-repair-of-glaucoma-drainage-device-tube-exposure-with-a-corneal-patch-graft-and-double-layer-amniotic-membrane-a-case-report"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,12,11]]},"references-count":16,"URL":"https:\/\/doi.org\/10.7759\/cureus.98955","relation":{},"ISSN":["2168-8184"],"issn-type":[{"value":"2168-8184","type":"print"}],"subject":[],"published":{"date-parts":[[2025,12,11]]}}}