{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,30]],"date-time":"2026-01-30T09:01:37Z","timestamp":1769763697348,"version":"3.49.0"},"reference-count":18,"publisher":"Elsevier BV","issue":"1","license":[{"start":{"date-parts":[[2017,2,1]],"date-time":"2017-02-01T00:00:00Z","timestamp":1485907200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2017,2,1]],"date-time":"2017-02-01T00:00:00Z","timestamp":1485907200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2024,4,3]],"date-time":"2024-04-03T00:00:00Z","timestamp":1712102400000},"content-version":"vor","delay-in-days":2618,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Clinical Medicine"],"published-print":{"date-parts":[[2017,2]]},"DOI":"10.7861\/clinmedicine.17-1-33","type":"journal-article","created":{"date-parts":[[2017,2,1]],"date-time":"2017-02-01T04:05:17Z","timestamp":1485921917000},"page":"33-36","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":7,"title":["Lead or be led: an update on leadless cardiac devices for general physicians"],"prefix":"10.1016","volume":"17","author":[{"given":"Benedict M","family":"Wiles","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Paul R","family":"Roberts","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.7861\/clinmedicine.17-1-33_bib1","first-page":"350","volume":"117","author":"Epstein","year":"2008","journal-title":"Circulation"},{"key":"10.7861\/clinmedicine.17-1-33_bib2","first-page":"iv","article-title":"Current trends in the use of cardiac implantable electronic devices and interventional electrophysiological procedures in the European Society of Cardiology member countries: 2015 report from the European Heart Rhythm Association","volume":"17","author":"Pekka Raatikainen","year":"2015","journal-title":"Europace"},{"key":"10.7861\/clinmedicine.17-1-33_bib3","doi-asserted-by":"crossref","first-page":"114","DOI":"10.1046\/j.1460-9592.2003.00162.x","article-title":"Lessons from the first patient with an implanted pacemaker: 1958\u20132001","volume":"26","author":"Larsson","year":"2003","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.7861\/clinmedicine.17-1-33_bib4","doi-asserted-by":"crossref","first-page":"2502","DOI":"10.1001\/jama.297.22.2502","article-title":"Cardiac resynchronization therapy for patients with left ventricular systolic sysfunction: a systematic review","volume":"297","author":"McAlister","year":"2007","journal-title":"JAMA"},{"key":"10.7861\/clinmedicine.17-1-33_bib5","doi-asserted-by":"crossref","first-page":"1297","DOI":"10.1161\/01.CIR.101.11.1297","article-title":"Canadian implantable defibrillator study (CIDS): a randomized trial of the implantable cardioverter defibrillator against amiodarone","volume":"101","author":"Connolly","year":"2000","journal-title":"Circulation"},{"key":"10.7861\/clinmedicine.17-1-33_bib6","doi-asserted-by":"crossref","first-page":"877","DOI":"10.1056\/NEJMoa013474","article-title":"Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction","volume":"346","author":"Moss","year":"2002","journal-title":"N Engl J Med"},{"key":"10.7861\/clinmedicine.17-1-33_bib7","doi-asserted-by":"crossref","first-page":"000177","DOI":"10.1136\/openhrt-2014-000177","article-title":"Trends in the incidence and prevalence of cardiac pacemaker insertions in an ageing population","volume":"1","author":"Bradshaw","year":"2014","journal-title":"Open Heart"},{"key":"10.7861\/clinmedicine.17-1-33_bib8","doi-asserted-by":"crossref","first-page":"1186","DOI":"10.1093\/eurheartj\/eht511","article-title":"Complications after cardiac implantable device implantations: an analysis of a complete, nationwide cohort in Denmark","volume":"35","author":"Kirkfeldt","year":"2014","journal-title":"Eur Heart J"},{"key":"10.7861\/clinmedicine.17-1-33_bib9","doi-asserted-by":"crossref","first-page":"2474","DOI":"10.1161\/CIRCULATIONAHA.106.663807","article-title":"Annual rate of transvenous defibrillation lead defects in implantable cardioverter defibrillators over a period of >10 years","volume":"115","author":"Kleemann","year":"2007","journal-title":"Circulation"},{"key":"10.7861\/clinmedicine.17-1-33_bib10","doi-asserted-by":"crossref","first-page":"1605","DOI":"10.1016\/j.jacc.2015.02.047","article-title":"Safety and efficacy of the totally subcutaneous implantable defibrillator: 2-year results from a pooled analysis of the IDE study and EFFORTLESS Registry","volume":"65","author":"Burke","year":"2015","journal-title":"J Am Coll Cardiol"},{"key":"10.7861\/clinmedicine.17-1-33_bib11","doi-asserted-by":"crossref","first-page":"359","DOI":"10.1111\/j.1540-8167.2011.02199.x","article-title":"Head-to-head comparison of arrhythmia discrimination performance of subcutaneous and transvenous ICD arrhythmia detection algorithms: the START study","volume":"23","author":"Gold","year":"2012","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.7861\/clinmedicine.17-1-33_bib12","doi-asserted-by":"crossref","first-page":"126","DOI":"10.1016\/j.ijcard.2015.05.135","article-title":"Inappropriate shocks in the subcutaneous ICD: incidence, predictors and management","volume":"195","author":"Olde Nordkamp","year":"2015","journal-title":"Int J Cardiol"},{"key":"10.7861\/clinmedicine.17-1-33_bib13","doi-asserted-by":"crossref","first-page":"533","DOI":"10.1056\/NEJMoa1511643","article-title":"A leadless intracardiac transcatheter pacing system","volume":"374","author":"Reynolds","year":"2016","journal-title":"N Engl J Med"},{"key":"10.7861\/clinmedicine.17-1-33_bib14","doi-asserted-by":"crossref","first-page":"1125","DOI":"10.1056\/NEJMoa1507192","article-title":"Percutaneous implantation of an entirely intracardiac leadless pacemaker","volume":"373","author":"Reddy","year":"2015","journal-title":"N Engl J Med"},{"key":"10.7861\/clinmedicine.17-1-33_bib15","doi-asserted-by":"crossref","first-page":"1740","DOI":"10.1093\/europace\/euv457","article-title":"Combined leadless pacemaker and subcutaneous implantable defibrillator therapy: feasibility, safety, and performance","volume":"18","author":"Tjong","year":"2016","journal-title":"Europace"},{"key":"10.7861\/clinmedicine.17-1-33_bib16","doi-asserted-by":"crossref","first-page":"2118","DOI":"10.1093\/eurheartj\/ehv723","article-title":"Alternate site cardiac resynchronization (ALSYNC): a prospective and multicentre study of left ventricular endocardial pacing for cardiac resynchronization therapy","volume":"37","author":"Morgan","year":"2016","journal-title":"Eur Heart J"},{"key":"10.7861\/clinmedicine.17-1-33_bib17","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1097\/HCO.0b013e32834dc3d4","article-title":"The risks and benefits of transseptal endocardial pacing","volume":"27","author":"Whinnett","year":"2012","journal-title":"Curr Opin Cardiol"},{"key":"10.7861\/clinmedicine.17-1-33_bib18","doi-asserted-by":"crossref","first-page":"681","DOI":"10.1093\/europace\/eut435","article-title":"Feasibility, safety, and short-term outcome of leadless ultrasound-based endocardial left ventricular resynchronization in heart failure patients: results of the wireless stimulation endocardially for CRT (Wise-CRT) study","volume":"16","author":"Auricchio","year":"2014","journal-title":"Europace"}],"container-title":["Clinical Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S147021182402308X?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S147021182402308X?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.7861\/clinmedicine.17-1-33","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,26]],"date-time":"2025-10-26T06:36:33Z","timestamp":1761460593000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S147021182402308X"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,2]]},"references-count":18,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2017,2]]}},"alternative-id":["S147021182402308X"],"URL":"https:\/\/doi.org\/10.7861\/clinmedicine.17-1-33","relation":{},"ISSN":["1470-2118"],"issn-type":[{"value":"1470-2118","type":"print"}],"subject":[],"published":{"date-parts":[[2017,2]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Lead or be led: an update on leadless cardiac devices for general physicians","name":"articletitle","label":"Article Title"},{"value":"Clinical Medicine","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.7861\/clinmedicine.17-1-33","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 Royal College of Physicians 2017. All rights reserved.","name":"copyright","label":"Copyright"}]}}