{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,18]],"date-time":"2026-05-18T14:04:28Z","timestamp":1779113068702,"version":"3.51.4"},"reference-count":30,"publisher":"Wiley","issue":"7","license":[{"start":{"date-parts":[[2016,5,26]],"date-time":"2016-05-26T00:00:00Z","timestamp":1464220800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["J of Ultrasound Medicine"],"published-print":{"date-parts":[[2016,7]]},"abstract":"<jats:sec><jats:title>Objectives<\/jats:title><jats:p>Neonates in the neonatal intensive care unit often require considerable support with endotracheal tubes, umbilical arterial and venous catheters, and peripherally inserted central venous catheters. Support device evaluation with radiography exposes neonates to ionizing radiation. This study evaluated the effectiveness of sonographic localization for endotracheal tubes, umbilical arterial and venous catheters, and peripherally inserted central venous catheters.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>This blinded prospective Institutional Review Board\u2013approved, Health Insurance Portability and Accountability Act\u2013compliant study with informed consent compared sonography to radiography for endotracheal tube, umbilical arterial and venous catheter, and peripherally inserted central venous catheter localization. Participants were consecutively recruited NICU patients of any weight, gestation, and chronologic age who had an endotracheal tube, umbilical arterial catheter, umbilical venous catheter, or peripherally inserted central venous catheter placed or adjusted and had subsequent radiographic confirmation within 24 hours. Sonographic evaluation was obtained as soon as possible, without prior review of the radiograph, and results were compared.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>Thirty sonographic studies were performed in 25 patients (14 male and 11 female), for a total of 50 lines and tubes: 18 umbilical venous catheters, 12 umbilical arterial catheters, 11 peripherally inserted central venous catheters, and 9 endotracheal tubes. Forty\u2010nine support devices (98%) were visualized with sonography, all concordant with radiography. Forty\u2010four were correctly positioned, and 6 were malpositioned. Sonography identified the location of umbilical venous catheters in all 18 cases (100%), umbilical arterial catheters in all 12 (100%), peripherally inserted central venous catheters in 10 (91%), and endotracheal tubes in 9 (100%).<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions<\/jats:title><jats:p>The effectiveness of sonography was excellent for evaluation of umbilical arterial and venous catheters, endotracheal tubes, and peripherally inserted central venous catheters. These results support the goal of further point\u2010of\u2010care training and accreditation to use sonography as a primary modality for complete evaluation of NICU support devices.<\/jats:p><\/jats:sec>","DOI":"10.7863\/ultra.15.06104","type":"journal-article","created":{"date-parts":[[2016,5,27]],"date-time":"2016-05-27T04:15:06Z","timestamp":1464322506000},"page":"1465-1473","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":47,"title":["Sonography for Complete Evaluation of Neonatal Intensive Care Unit Central Support Devices"],"prefix":"10.1002","volume":"35","author":[{"given":"David","family":"Saul","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Samuel","family":"Ajayi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"David L.","family":"Schutzman","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mindy M.","family":"Horrow","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2016,5,26]]},"reference":[{"key":"e_1_2_6_2_1","article-title":"Image Gently","author":"Alliance for Radiation Safety in Pediatric Imaging","year":"2014","journal-title":"Alliance for Radiation Safety in Pediatric Imaging website"},{"key":"e_1_2_6_3_1","doi-asserted-by":"publisher","DOI":"10.1136\/fn.75.1.F62"},{"key":"e_1_2_6_4_1","doi-asserted-by":"publisher","DOI":"10.1038\/sj.jp.7210782"},{"key":"e_1_2_6_5_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.siny.2010.06.005"},{"key":"e_1_2_6_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0022-3476(95)70366-7"},{"key":"e_1_2_6_7_1","doi-asserted-by":"publisher","DOI":"10.1007\/BF02386588"},{"key":"e_1_2_6_8_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1651-2227.2000.tb00769.x"},{"key":"e_1_2_6_9_1","doi-asserted-by":"publisher","DOI":"10.1148\/radiology.197.2.7480709"},{"key":"e_1_2_6_10_1","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.327.7411.361"},{"key":"e_1_2_6_11_1","doi-asserted-by":"publisher","DOI":"10.1891\/0730-0832.29.1.23"},{"key":"e_1_2_6_12_1","doi-asserted-by":"publisher","DOI":"10.1542\/peds.2006-2959"},{"key":"e_1_2_6_13_1","doi-asserted-by":"publisher","DOI":"10.1148\/radiology.160.1.3520649"},{"key":"e_1_2_6_14_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1553-2712.2012.01306.x"},{"key":"e_1_2_6_15_1","doi-asserted-by":"publisher","DOI":"10.1259\/bjr.75.895.750590"},{"key":"e_1_2_6_16_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jpedsurg.2013.02.016"},{"key":"e_1_2_6_17_1","doi-asserted-by":"publisher","DOI":"10.3109\/0284186X.2014.899434"},{"key":"e_1_2_6_18_1","volume-title":"Atlas of Procedures in Neonatology","author":"MacDonald G","year":"2007"},{"key":"e_1_2_6_19_1","doi-asserted-by":"publisher","DOI":"10.1038\/sj.jp.7210851"},{"key":"e_1_2_6_20_1","first-page":"183","article-title":"Accuracy of the distance between suprasternal notch and superior iliac spine to determine umbilical arterial catheter length","volume":"93","author":"Sritipsukho P","year":"2010","journal-title":"J Med Assoc Thai"},{"key":"e_1_2_6_21_1","doi-asserted-by":"publisher","DOI":"10.1542\/peds.107.2.e28"},{"key":"e_1_2_6_22_1","doi-asserted-by":"publisher","DOI":"10.1038\/jp.2010.128"},{"key":"e_1_2_6_23_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.resuscitation.2011.11.026"},{"key":"e_1_2_6_24_1","doi-asserted-by":"publisher","DOI":"10.1097\/PCC.0b013e31829f5efa"},{"key":"e_1_2_6_25_1","doi-asserted-by":"publisher","DOI":"10.1038\/jp.2013.58"},{"key":"e_1_2_6_26_1","doi-asserted-by":"publisher","DOI":"10.1055\/s-0031-1295649"},{"key":"e_1_2_6_27_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvir.2013.08.020"},{"key":"e_1_2_6_28_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.annemergmed.2006.07.004"},{"key":"e_1_2_6_29_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1553-2712.2000.tb02055.x"},{"key":"e_1_2_6_30_1","doi-asserted-by":"publisher","DOI":"10.1542\/peds.2008-2828"},{"key":"e_1_2_6_31_1","doi-asserted-by":"publisher","DOI":"10.7863\/jum.2008.27.5.785"}],"container-title":["Journal of Ultrasound in Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.7863%2Fultra.15.06104","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.7863%2Fultra.15.06104","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.7863\/ultra.15.06104","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,26]],"date-time":"2023-09-26T12:42:45Z","timestamp":1695732165000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.7863\/ultra.15.06104"}},"subtitle":["A Pilot Study"],"short-title":[],"issued":{"date-parts":[[2016,5,26]]},"references-count":30,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2016,7]]}},"alternative-id":["10.7863\/ultra.15.06104"],"URL":"https:\/\/doi.org\/10.7863\/ultra.15.06104","archive":["Portico"],"relation":{},"ISSN":["0278-4297","1550-9613"],"issn-type":[{"value":"0278-4297","type":"print"},{"value":"1550-9613","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,5,26]]},"assertion":[{"value":"2015-06-29","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2015-10-19","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2016-05-26","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}