{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T06:01:19Z","timestamp":1787032879774,"version":"build-2736575974"},"reference-count":17,"publisher":"The University of Occupational and Environmental Health, Japan","issue":"2","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J UOEH"],"published-print":{"date-parts":[[2015]]},"DOI":"10.7888\/juoeh.37.111","type":"journal-article","created":{"date-parts":[[2015,6,12]],"date-time":"2015-06-12T18:10:08Z","timestamp":1434132608000},"page":"111-119","source":"Crossref","is-referenced-by-count":23,"title":["Comparison of Functional Outcome Between Early and Delayed Internal Fixation Using Volar Locking Plate for Distal Radius Fractures"],"prefix":"10.7888","volume":"37","author":[{"given":"Kazuta","family":"YAMASHITA","sequence":"first","affiliation":[{"name":"Department of Orthopaedic Surgery, Kagawa Rosai Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yukichi","family":"ZENKE","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, University Hospital of Occupational and Environmental Health, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Akinori","family":"SAKAI","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, School of Medicine, University of Occupational and Environmental Health, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Toshihisa","family":"OSHIGE","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, University Hospital of Occupational and Environmental Health, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shiro","family":"MORITANI","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Kagawa Rosai Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takashi","family":"MAEHARA","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Kagawa Rosai Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"4637","reference":[{"key":"1","doi-asserted-by":"crossref","unstructured":"1. Souer JS, Ring D, Matschke S, Audige L, Maren-Hubert M &amp; Jupiter J (2010) : Comparison of functional outcome after volar plate fixation with 2.4-mm titanium versus 3.5-mm stainless-steel plate for extra-articular fracture of distal radius. J Hand Surg Am 35: 398-405","DOI":"10.1016\/j.jhsa.2009.11.023"},{"key":"2","unstructured":"2. Lafontaine M, Delince P, Hardy D &amp; Simons M (1989): Instability of fractures of the lower end of the radius: apropos of a series of 167 cases. Acta Orthop Belg 55: 203-216"},{"key":"3","doi-asserted-by":"crossref","unstructured":"3. Mackenney PJ, McQueen MM &amp; Elton R (2006): Prediction of instability in distal radial fractures. J Bone Joint Surg Am 88: 1944-1951","DOI":"10.2106\/JBJS.D.02520"},{"key":"4","doi-asserted-by":"crossref","unstructured":"4. Earnshaw SA, Aladin A, Surendran S &amp; Moran CG (2002): Closed reduction of Colles fractures: comparison of manual manipulation and finger-trap traction: A prospective, randomized study. J Bone Joint Surg Am 84: 354-358","DOI":"10.2106\/00004623-200203000-00004"},{"key":"5","doi-asserted-by":"crossref","unstructured":"5. Willis AA, Kutsumi K, Zobitz ME &amp; Cooney WP 3rd (2006): Internal fixation of dorsally displaced fractures of the distal part of the radius. a biomechanical analysis of volar plate fracture stability. J Bone Joint Surg Am 88: 2411-2417","DOI":"10.2106\/JBJS.E.00946"},{"key":"6","doi-asserted-by":"crossref","unstructured":"6. Rozental TD &amp; Blazar PE (2006): Functional outcome and complications after volar plating for dorsally displaced, unstable fractures of the distal radius. J Hand Surg Am 31: 359-365","DOI":"10.1016\/j.jhsa.2005.10.010"},{"key":"7","doi-asserted-by":"crossref","unstructured":"7. Orbay JL &amp; Fernandez DL (2004): Volar fixed-angle plate fixation for unstable distal radius fractures in the elderly patient. J Hand Surg Am 29: 96-102","DOI":"10.1016\/j.jhsa.2003.09.015"},{"key":"8","doi-asserted-by":"crossref","unstructured":"8. Musgrave DS &amp; Idler RS (2005): Volar fixation of dorsally displaced distal radius fractures using the 2.4-mm locking compression plates. J Hand Surg Am 30: 743-749","DOI":"10.1016\/j.jhsa.2005.03.006"},{"key":"9","doi-asserted-by":"crossref","unstructured":"9. Jupiter JB &amp; Fernandez DL (1997): Comparative classification for fractures of the distal end of the radius. J Hand Surg Am 22: 563-571","DOI":"10.1016\/S0363-5023(97)80110-4"},{"key":"10","doi-asserted-by":"crossref","unstructured":"10. Orbay J, Badia A, Khoury RK, Gonzalez E &amp; Indriago I (2004): Volar fixed-angle fixation of distal radius fractures: the DVR plate. Tech Hand Up Extrem Surg 8: 142-148","DOI":"10.1097\/01.bth.0000126570.82826.0a"},{"key":"11","doi-asserted-by":"crossref","unstructured":"11. Orbay JL, Touhami A &amp; Orbay C (2005): Fixed angle fixation of distal radius fractures through a minimally invasive approach. Tech Hand Up Extrem Surg 9: 142-148","DOI":"10.1097\/01.bth.0000173374.97406.70"},{"key":"12","doi-asserted-by":"crossref","unstructured":"12. Hudak PL, Amadio PC &amp; Bombardier C (1996): Development of an upper extremity outcome measure: the DASH (disabilities of the arm, shoulder and hand) [corrected] The Upper Extremity Collaborative Group (UECG). Am J Ind Med 29: 602-608","DOI":"10.1002\/(SICI)1097-0274(199606)29:6<602::AID-AJIM4>3.0.CO;2-L"},{"key":"13","unstructured":"13. Mathiowetz V, Kashman N, Volland G, Weber K, Dowe M &amp; Rogers S (1985): Grip and pinch strength: normative data for adults. Arch Phys Med Rehabil 66: 69-74"},{"key":"14","doi-asserted-by":"crossref","unstructured":"14. Kreder HJ, Hanel DP, McKee M, Jupiter J, McGillivary G &amp; Swiontkowski MF (1996): X-ray film measurements for healed distal radius fractures. J Hand Surg Am 21: 31-39","DOI":"10.1016\/S0363-5023(96)80151-1"},{"key":"15","doi-asserted-by":"crossref","unstructured":"15. Abdelhady AM (2013): Timing of shoulder arthroplasty in comminuted proximal humerus fracture, how much does it matter? Eur J Orthop Surg Traumatol 23: 515-519","DOI":"10.1007\/s00590-012-1025-9"},{"key":"16","doi-asserted-by":"crossref","unstructured":"16. Mathews A &amp; Ridgeway V (1981): Personality and surgical recovery: a review. Br J Clin Psychol 20: 243-260","DOI":"10.1111\/j.2044-8260.1981.tb00525.x"},{"key":"17","doi-asserted-by":"crossref","unstructured":"17. Sun T, Wang X, Liu Z, Chen X &amp; Zhang J (2011): Plasma concentrations of pro- and anti-inflammatory cytokines and outcome prediction in elderly hip fracture patients. Injury 42: 707-713","DOI":"10.1016\/j.injury.2011.01.010"}],"container-title":["Journal of UOEH"],"original-title":["\u6a48\u9aa8\u9060\u4f4d\u7aef\u9aa8\u6298\u306b\u5bfe\u3059\u308b\u638c\u5074\u30ed\u30c3\u30ad\u30f3\u30b0\u30d7\u30ec\u30fc\u30c8\u3092\u7528\u3044\u305f\u65e9\u671f\u624b\u8853\u7fa4\u3068\u5f85\u6a5f\u624b\u8853\u7fa4\u306e\u6a5f\u80fd\u4e88\u5f8c\u306e\u6bd4\u8f03\u691c\u8a0e"],"language":"en","deposited":{"date-parts":[[2017,6,23]],"date-time":"2017-06-23T09:36:24Z","timestamp":1498210584000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/juoeh\/37\/2\/37_111\/_article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015]]},"references-count":17,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2015]]}},"URL":"https:\/\/doi.org\/10.7888\/juoeh.37.111","relation":{},"ISSN":["0387-821X","2187-2864"],"issn-type":[{"value":"0387-821X","type":"print"},{"value":"2187-2864","type":"electronic"}],"subject":[],"published":{"date-parts":[[2015]]}}}